Cargando…

Across-frequency combination of interaural time difference in bilateral cochlear implant listeners

The current study examined how cochlear implant (CI) listeners combine temporally interleaved envelope-ITD information across two sites of stimulation. When two cochlear sites jointly transmit ITD information, one possibility is that CI listeners can extract the most reliable ITD cues available. As...

Descripción completa

Detalles Bibliográficos
Autores principales: Ihlefeld, Antje, Kan, Alan, Litovsky, Ruth Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3949319/
https://www.ncbi.nlm.nih.gov/pubmed/24653681
http://dx.doi.org/10.3389/fnsys.2014.00022
_version_ 1782306890241277952
author Ihlefeld, Antje
Kan, Alan
Litovsky, Ruth Y.
author_facet Ihlefeld, Antje
Kan, Alan
Litovsky, Ruth Y.
author_sort Ihlefeld, Antje
collection PubMed
description The current study examined how cochlear implant (CI) listeners combine temporally interleaved envelope-ITD information across two sites of stimulation. When two cochlear sites jointly transmit ITD information, one possibility is that CI listeners can extract the most reliable ITD cues available. As a result, ITD sensitivity would be sustained or enhanced compared to single-site stimulation. Alternatively, mutual interference across multiple sites of ITD stimulation could worsen dual-site performance compared to listening to the better of two electrode pairs. Two experiments used direct stimulation to examine how CI users can integrate ITDs across two pairs of electrodes. Experiment 1 tested ITD discrimination for two stimulation sites using 100-Hz sinusoidally modulated 1000-pps-carrier pulse trains. Experiment 2 used the same stimuli ramped with 100 ms windows, as a control condition with minimized onset cues. For all stimuli, performance improved monotonically with increasing modulation depth. Results show that when CI listeners are stimulated with electrode pairs at two cochlear sites, sensitivity to ITDs was similar to that seen when only the electrode pair with better sensitivity was activated. None of the listeners showed a decrement in performance from the worse electrode pair. This could be achieved either by listening to the better electrode pair or by truly integrating the information across cochlear sites.
format Online
Article
Text
id pubmed-3949319
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-39493192014-03-20 Across-frequency combination of interaural time difference in bilateral cochlear implant listeners Ihlefeld, Antje Kan, Alan Litovsky, Ruth Y. Front Syst Neurosci Neuroscience The current study examined how cochlear implant (CI) listeners combine temporally interleaved envelope-ITD information across two sites of stimulation. When two cochlear sites jointly transmit ITD information, one possibility is that CI listeners can extract the most reliable ITD cues available. As a result, ITD sensitivity would be sustained or enhanced compared to single-site stimulation. Alternatively, mutual interference across multiple sites of ITD stimulation could worsen dual-site performance compared to listening to the better of two electrode pairs. Two experiments used direct stimulation to examine how CI users can integrate ITDs across two pairs of electrodes. Experiment 1 tested ITD discrimination for two stimulation sites using 100-Hz sinusoidally modulated 1000-pps-carrier pulse trains. Experiment 2 used the same stimuli ramped with 100 ms windows, as a control condition with minimized onset cues. For all stimuli, performance improved monotonically with increasing modulation depth. Results show that when CI listeners are stimulated with electrode pairs at two cochlear sites, sensitivity to ITDs was similar to that seen when only the electrode pair with better sensitivity was activated. None of the listeners showed a decrement in performance from the worse electrode pair. This could be achieved either by listening to the better electrode pair or by truly integrating the information across cochlear sites. Frontiers Media S.A. 2014-03-11 /pmc/articles/PMC3949319/ /pubmed/24653681 http://dx.doi.org/10.3389/fnsys.2014.00022 Text en Copyright © 2014 Ihlefeld, Kan and Litovsky. http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Ihlefeld, Antje
Kan, Alan
Litovsky, Ruth Y.
Across-frequency combination of interaural time difference in bilateral cochlear implant listeners
title Across-frequency combination of interaural time difference in bilateral cochlear implant listeners
title_full Across-frequency combination of interaural time difference in bilateral cochlear implant listeners
title_fullStr Across-frequency combination of interaural time difference in bilateral cochlear implant listeners
title_full_unstemmed Across-frequency combination of interaural time difference in bilateral cochlear implant listeners
title_short Across-frequency combination of interaural time difference in bilateral cochlear implant listeners
title_sort across-frequency combination of interaural time difference in bilateral cochlear implant listeners
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3949319/
https://www.ncbi.nlm.nih.gov/pubmed/24653681
http://dx.doi.org/10.3389/fnsys.2014.00022
work_keys_str_mv AT ihlefeldantje acrossfrequencycombinationofinterauraltimedifferenceinbilateralcochlearimplantlisteners
AT kanalan acrossfrequencycombinationofinterauraltimedifferenceinbilateralcochlearimplantlisteners
AT litovskyruthy acrossfrequencycombinationofinterauraltimedifferenceinbilateralcochlearimplantlisteners