Cargando…
Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography
We investigated how well repetitive finger tapping movements can be decoded from scalp electroencephalography (EEG) signals. A linear decoder with memory was used to infer continuous index finger angular velocities from the low-pass filtered fluctuations of the amplitude of a plurality of EEG signal...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3952032/ https://www.ncbi.nlm.nih.gov/pubmed/24659964 http://dx.doi.org/10.3389/fneng.2014.00003 |
_version_ | 1782307154720456704 |
---|---|
author | Paek, Andrew Y. Agashe, Harshavardhan A. Contreras-Vidal, José L. |
author_facet | Paek, Andrew Y. Agashe, Harshavardhan A. Contreras-Vidal, José L. |
author_sort | Paek, Andrew Y. |
collection | PubMed |
description | We investigated how well repetitive finger tapping movements can be decoded from scalp electroencephalography (EEG) signals. A linear decoder with memory was used to infer continuous index finger angular velocities from the low-pass filtered fluctuations of the amplitude of a plurality of EEG signals distributed across the scalp. To evaluate the accuracy of the decoder, the Pearson's correlation coefficient (r) between the observed and predicted trajectories was calculated in a 10-fold cross-validation scheme. We also assessed attempts to decode finger kinematics from EEG data that was cleaned with independent component analysis (ICA), EEG data from peripheral sensors, and EEG data from rest periods. A genetic algorithm (GA) was used to select combinations of EEG channels that maximized decoding accuracies. Our results (lower quartile r = 0.18, median r = 0.36, upper quartile r = 0.50) show that delta-band EEG signals contain useful information that can be used to infer finger kinematics. Further, the highest decoding accuracies were characterized by highly correlated delta band EEG activity mostly localized to the contralateral central areas of the scalp. Spectral analysis of EEG also showed bilateral alpha band (8–13 Hz) event related desynchronizations (ERDs) and contralateral beta band (20–30 Hz) event related synchronizations (ERSs) localized over central scalp areas. Overall, this study demonstrates the feasibility of decoding finger kinematics from scalp EEG signals. |
format | Online Article Text |
id | pubmed-3952032 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-39520322014-03-21 Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography Paek, Andrew Y. Agashe, Harshavardhan A. Contreras-Vidal, José L. Front Neuroeng Neuroscience We investigated how well repetitive finger tapping movements can be decoded from scalp electroencephalography (EEG) signals. A linear decoder with memory was used to infer continuous index finger angular velocities from the low-pass filtered fluctuations of the amplitude of a plurality of EEG signals distributed across the scalp. To evaluate the accuracy of the decoder, the Pearson's correlation coefficient (r) between the observed and predicted trajectories was calculated in a 10-fold cross-validation scheme. We also assessed attempts to decode finger kinematics from EEG data that was cleaned with independent component analysis (ICA), EEG data from peripheral sensors, and EEG data from rest periods. A genetic algorithm (GA) was used to select combinations of EEG channels that maximized decoding accuracies. Our results (lower quartile r = 0.18, median r = 0.36, upper quartile r = 0.50) show that delta-band EEG signals contain useful information that can be used to infer finger kinematics. Further, the highest decoding accuracies were characterized by highly correlated delta band EEG activity mostly localized to the contralateral central areas of the scalp. Spectral analysis of EEG also showed bilateral alpha band (8–13 Hz) event related desynchronizations (ERDs) and contralateral beta band (20–30 Hz) event related synchronizations (ERSs) localized over central scalp areas. Overall, this study demonstrates the feasibility of decoding finger kinematics from scalp EEG signals. Frontiers Media S.A. 2014-03-13 /pmc/articles/PMC3952032/ /pubmed/24659964 http://dx.doi.org/10.3389/fneng.2014.00003 Text en Copyright © 2014 Paek, Agashe and Contreras-Vidal. http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Paek, Andrew Y. Agashe, Harshavardhan A. Contreras-Vidal, José L. Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
title | Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
title_full | Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
title_fullStr | Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
title_full_unstemmed | Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
title_short | Decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
title_sort | decoding repetitive finger movements with brain activity acquired via non-invasive electroencephalography |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3952032/ https://www.ncbi.nlm.nih.gov/pubmed/24659964 http://dx.doi.org/10.3389/fneng.2014.00003 |
work_keys_str_mv | AT paekandrewy decodingrepetitivefingermovementswithbrainactivityacquiredvianoninvasiveelectroencephalography AT agasheharshavardhana decodingrepetitivefingermovementswithbrainactivityacquiredvianoninvasiveelectroencephalography AT contrerasvidaljosel decodingrepetitivefingermovementswithbrainactivityacquiredvianoninvasiveelectroencephalography |