Cargando…

Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.

[Image: see text] A direct, ambient ionization method has been developed for the determination of creatinine in urine that combines derivatization and thermal desorption with extractive electrospray ionization and ion mobility-mass spectrometry. The volatility of creatinine was enhanced by a rapid o...

Descripción completa

Detalles Bibliográficos
Autores principales: Devenport, Neil A., Blenkhorn, Daniel J., Weston, Daniel J., Reynolds, James C., Creaser, Colin S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2013
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3953925/
https://www.ncbi.nlm.nih.gov/pubmed/24279641
http://dx.doi.org/10.1021/ac403133t
_version_ 1782307416377917440
author Devenport, Neil A.
Blenkhorn, Daniel J.
Weston, Daniel J.
Reynolds, James C.
Creaser, Colin S.
author_facet Devenport, Neil A.
Blenkhorn, Daniel J.
Weston, Daniel J.
Reynolds, James C.
Creaser, Colin S.
author_sort Devenport, Neil A.
collection PubMed
description [Image: see text] A direct, ambient ionization method has been developed for the determination of creatinine in urine that combines derivatization and thermal desorption with extractive electrospray ionization and ion mobility-mass spectrometry. The volatility of creatinine was enhanced by a rapid on-probe aqueous acylation reaction, using a custom-made thermal desorption probe, allowing thermal desorption and ionization of the monoacylated derivative. The monoacyl creatinine [M + H](+) ion (m/z 156) was subjected to mass-to-charge selection and collision induced dissociation to remove the acyl group, generating the protonated creatinine [M + H](+) product ion at m/z 114 before an ion mobility separation was applied to reduce chemical noise. Stable isotope dilution using creatinine-d(3) as internal standard was used for quantitative measurements. The direct on-probe derivatization allows high sample throughput with a typical cycle time of 1 min per sample. The method shows good linearity (R(2) = 0.986) and repeatability (%RSD 8–10%) in the range of 0.25–2.0 mg/mL. The creatinine concentrations in diluted urine samples from a healthy individual were determined to contain a mean concentration of 1.44 mg/mL creatinine with a precision (%RSD) of 9.9%. The reactive ambient ionization approach demonstrated here has potential for the determination of involatile analytes in urine and other biofluids.
format Online
Article
Text
id pubmed-3953925
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-39539252014-03-14 Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry. Devenport, Neil A. Blenkhorn, Daniel J. Weston, Daniel J. Reynolds, James C. Creaser, Colin S. Anal Chem [Image: see text] A direct, ambient ionization method has been developed for the determination of creatinine in urine that combines derivatization and thermal desorption with extractive electrospray ionization and ion mobility-mass spectrometry. The volatility of creatinine was enhanced by a rapid on-probe aqueous acylation reaction, using a custom-made thermal desorption probe, allowing thermal desorption and ionization of the monoacylated derivative. The monoacyl creatinine [M + H](+) ion (m/z 156) was subjected to mass-to-charge selection and collision induced dissociation to remove the acyl group, generating the protonated creatinine [M + H](+) product ion at m/z 114 before an ion mobility separation was applied to reduce chemical noise. Stable isotope dilution using creatinine-d(3) as internal standard was used for quantitative measurements. The direct on-probe derivatization allows high sample throughput with a typical cycle time of 1 min per sample. The method shows good linearity (R(2) = 0.986) and repeatability (%RSD 8–10%) in the range of 0.25–2.0 mg/mL. The creatinine concentrations in diluted urine samples from a healthy individual were determined to contain a mean concentration of 1.44 mg/mL creatinine with a precision (%RSD) of 9.9%. The reactive ambient ionization approach demonstrated here has potential for the determination of involatile analytes in urine and other biofluids. American Chemical Society 2013-11-27 2014-01-07 /pmc/articles/PMC3953925/ /pubmed/24279641 http://dx.doi.org/10.1021/ac403133t Text en Copyright © 2013 American Chemical Society Terms of Use CC-BY (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html)
spellingShingle Devenport, Neil A.
Blenkhorn, Daniel J.
Weston, Daniel J.
Reynolds, James C.
Creaser, Colin S.
Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.
title Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.
title_full Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.
title_fullStr Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.
title_full_unstemmed Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.
title_short Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.
title_sort direct determination of urinary creatinine by reactive-thermal desorption-extractive electrospray-ion mobility-tandem mass spectrometry.
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3953925/
https://www.ncbi.nlm.nih.gov/pubmed/24279641
http://dx.doi.org/10.1021/ac403133t
work_keys_str_mv AT devenportneila directdeterminationofurinarycreatininebyreactivethermaldesorptionextractiveelectrosprayionmobilitytandemmassspectrometry
AT blenkhorndanielj directdeterminationofurinarycreatininebyreactivethermaldesorptionextractiveelectrosprayionmobilitytandemmassspectrometry
AT westondanielj directdeterminationofurinarycreatininebyreactivethermaldesorptionextractiveelectrosprayionmobilitytandemmassspectrometry
AT reynoldsjamesc directdeterminationofurinarycreatininebyreactivethermaldesorptionextractiveelectrosprayionmobilitytandemmassspectrometry
AT creasercolins directdeterminationofurinarycreatininebyreactivethermaldesorptionextractiveelectrosprayionmobilitytandemmassspectrometry