Cargando…
The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3′,5,5′-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester or...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955136/ https://www.ncbi.nlm.nih.gov/pubmed/24672141 http://dx.doi.org/10.1007/s11270-014-1866-4 |
_version_ | 1782307538668093440 |
---|---|
author | Kowalski, Bartosz Mazur, Maciej |
author_facet | Kowalski, Bartosz Mazur, Maciej |
author_sort | Kowalski, Bartosz |
collection | PubMed |
description | Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3′,5,5′-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester organophosphate flame retardants (OPFRs) tris(2,3-dibromopropyl) phosphate (TBPP), ethylhexyl diphenyl phosphate (EHDP) and triphenyl phosphate (TPhP). Reversed phase ultrahigh-performance liquid chromatography (UHPLC) with a UV detector, different chromatographic columns, different mobile phases and gradient elution programmes were used to obtain the best separations within the shortest possible time. Solid-phase extraction (SPE) was examined as a pre-concentration step from distilled water. The column with the highest recoveries (the Bond Elut ENV column gave recoveries over 70 % for all compounds) was then tested on 1-L blank surface water samples. The proposed analytical procedure was applied for the determination of FRs in surface water samples. The concentrations of FRs found in water samples ranged from 0.03 (TPhP) to 3.10 μg L(−1) (HBCD). Method detection limits (MDLs) ranged from 0.008 to 0.518 μg L(−1), and method quantification limits (MQLs) ranged from 0.023 to 1.555 μg L(−1) for all compounds. |
format | Online Article Text |
id | pubmed-3955136 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-39551362014-03-24 The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method Kowalski, Bartosz Mazur, Maciej Water Air Soil Pollut Article Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3′,5,5′-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester organophosphate flame retardants (OPFRs) tris(2,3-dibromopropyl) phosphate (TBPP), ethylhexyl diphenyl phosphate (EHDP) and triphenyl phosphate (TPhP). Reversed phase ultrahigh-performance liquid chromatography (UHPLC) with a UV detector, different chromatographic columns, different mobile phases and gradient elution programmes were used to obtain the best separations within the shortest possible time. Solid-phase extraction (SPE) was examined as a pre-concentration step from distilled water. The column with the highest recoveries (the Bond Elut ENV column gave recoveries over 70 % for all compounds) was then tested on 1-L blank surface water samples. The proposed analytical procedure was applied for the determination of FRs in surface water samples. The concentrations of FRs found in water samples ranged from 0.03 (TPhP) to 3.10 μg L(−1) (HBCD). Method detection limits (MDLs) ranged from 0.008 to 0.518 μg L(−1), and method quantification limits (MQLs) ranged from 0.023 to 1.555 μg L(−1) for all compounds. Springer International Publishing 2014-02-12 2014 /pmc/articles/PMC3955136/ /pubmed/24672141 http://dx.doi.org/10.1007/s11270-014-1866-4 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Article Kowalski, Bartosz Mazur, Maciej The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method |
title | The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method |
title_full | The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method |
title_fullStr | The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method |
title_full_unstemmed | The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method |
title_short | The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method |
title_sort | simultaneous determination of six flame retardants in water samples using spe pre-concentration and uhplc-uv method |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955136/ https://www.ncbi.nlm.nih.gov/pubmed/24672141 http://dx.doi.org/10.1007/s11270-014-1866-4 |
work_keys_str_mv | AT kowalskibartosz thesimultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod AT mazurmaciej thesimultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod AT kowalskibartosz simultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod AT mazurmaciej simultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod |