Cargando…

The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method

Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3′,5,5′-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester or...

Descripción completa

Detalles Bibliográficos
Autores principales: Kowalski, Bartosz, Mazur, Maciej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955136/
https://www.ncbi.nlm.nih.gov/pubmed/24672141
http://dx.doi.org/10.1007/s11270-014-1866-4
_version_ 1782307538668093440
author Kowalski, Bartosz
Mazur, Maciej
author_facet Kowalski, Bartosz
Mazur, Maciej
author_sort Kowalski, Bartosz
collection PubMed
description Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3′,5,5′-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester organophosphate flame retardants (OPFRs) tris(2,3-dibromopropyl) phosphate (TBPP), ethylhexyl diphenyl phosphate (EHDP) and triphenyl phosphate (TPhP). Reversed phase ultrahigh-performance liquid chromatography (UHPLC) with a UV detector, different chromatographic columns, different mobile phases and gradient elution programmes were used to obtain the best separations within the shortest possible time. Solid-phase extraction (SPE) was examined as a pre-concentration step from distilled water. The column with the highest recoveries (the Bond Elut ENV column gave recoveries over 70 % for all compounds) was then tested on 1-L blank surface water samples. The proposed analytical procedure was applied for the determination of FRs in surface water samples. The concentrations of FRs found in water samples ranged from 0.03 (TPhP) to 3.10 μg L(−1) (HBCD). Method detection limits (MDLs) ranged from 0.008 to 0.518 μg L(−1), and method quantification limits (MQLs) ranged from 0.023 to 1.555 μg L(−1) for all compounds.
format Online
Article
Text
id pubmed-3955136
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-39551362014-03-24 The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method Kowalski, Bartosz Mazur, Maciej Water Air Soil Pollut Article Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3′,5,5′-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester organophosphate flame retardants (OPFRs) tris(2,3-dibromopropyl) phosphate (TBPP), ethylhexyl diphenyl phosphate (EHDP) and triphenyl phosphate (TPhP). Reversed phase ultrahigh-performance liquid chromatography (UHPLC) with a UV detector, different chromatographic columns, different mobile phases and gradient elution programmes were used to obtain the best separations within the shortest possible time. Solid-phase extraction (SPE) was examined as a pre-concentration step from distilled water. The column with the highest recoveries (the Bond Elut ENV column gave recoveries over 70 % for all compounds) was then tested on 1-L blank surface water samples. The proposed analytical procedure was applied for the determination of FRs in surface water samples. The concentrations of FRs found in water samples ranged from 0.03 (TPhP) to 3.10 μg L(−1) (HBCD). Method detection limits (MDLs) ranged from 0.008 to 0.518 μg L(−1), and method quantification limits (MQLs) ranged from 0.023 to 1.555 μg L(−1) for all compounds. Springer International Publishing 2014-02-12 2014 /pmc/articles/PMC3955136/ /pubmed/24672141 http://dx.doi.org/10.1007/s11270-014-1866-4 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Article
Kowalski, Bartosz
Mazur, Maciej
The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
title The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
title_full The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
title_fullStr The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
title_full_unstemmed The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
title_short The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method
title_sort simultaneous determination of six flame retardants in water samples using spe pre-concentration and uhplc-uv method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955136/
https://www.ncbi.nlm.nih.gov/pubmed/24672141
http://dx.doi.org/10.1007/s11270-014-1866-4
work_keys_str_mv AT kowalskibartosz thesimultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod
AT mazurmaciej thesimultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod
AT kowalskibartosz simultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod
AT mazurmaciej simultaneousdeterminationofsixflameretardantsinwatersamplesusingspepreconcentrationanduhplcuvmethod