A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study
BACKGROUND: Accurate working length determination is a pre-requisite for a successful endodontic treatment. Even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. The purpose of this in vivo/ex vivo comparative stu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955316/ https://www.ncbi.nlm.nih.gov/pubmed/24688561 |
_version_ | 1782307555092987904 |
---|---|
author | Khursheed, Irfana Bansal, Ruchika Bansal, Tajinder Singh, Harkanwal Preet Yadav, Madhulika Reddy, K. Jetender |
author_facet | Khursheed, Irfana Bansal, Ruchika Bansal, Tajinder Singh, Harkanwal Preet Yadav, Madhulika Reddy, K. Jetender |
author_sort | Khursheed, Irfana |
collection | PubMed |
description | BACKGROUND: Accurate working length determination is a pre-requisite for a successful endodontic treatment. Even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. The purpose of this in vivo/ex vivo comparative study was to determine the accuracy in measuring the working length of root canal using Direct Digital Radiographic Method (Radiovisiography or RVG) and ProPex electronic apex locator in the presence of three different irrigating solutions: 0.9% normal saline, 2% chlorhexidine, 3% NaOCl solutions. MATERIALS AND METHODS: Forty single-rooted human teeth scheduled for extraction with mature apices were selected for this study. Measurements were performed by using RVG and ProPex in the presence of irrigating solutions. After extraction of the teeth, light microscope was used to confirm visually the relationship of the tip of the endodontic file to the apical foramen, and actual lengths were determined by reducing 0.5 mm from this length. The statistical analysis was performed by one-way ANOVA test and Tukey-HSD post hoc procedure. P < 0.05 was considered as significant. RESULTS: No significant difference was found between overall mean electronic working length and digital radiographic length; however, prediction error (P < 0.05) was significant with respect to different irrigants. Among the irrigating solutions, chlorhexidine gluconate had the smallest distance to the actual lengths, whereas NaOCl had the greatest. CONCLUSION: Electronic apex locator ProPex yielded best result in the presence of chlorhexidine, whereas the largest error was demonstrated with NaOCl indicating that higher electroconductive irrigating solutions affect the precision of multi-frequency apex locators. |
format | Online Article Text |
id | pubmed-3955316 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-39553162014-03-31 A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study Khursheed, Irfana Bansal, Ruchika Bansal, Tajinder Singh, Harkanwal Preet Yadav, Madhulika Reddy, K. Jetender Dent Res J (Isfahan) Original Article BACKGROUND: Accurate working length determination is a pre-requisite for a successful endodontic treatment. Even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. The purpose of this in vivo/ex vivo comparative study was to determine the accuracy in measuring the working length of root canal using Direct Digital Radiographic Method (Radiovisiography or RVG) and ProPex electronic apex locator in the presence of three different irrigating solutions: 0.9% normal saline, 2% chlorhexidine, 3% NaOCl solutions. MATERIALS AND METHODS: Forty single-rooted human teeth scheduled for extraction with mature apices were selected for this study. Measurements were performed by using RVG and ProPex in the presence of irrigating solutions. After extraction of the teeth, light microscope was used to confirm visually the relationship of the tip of the endodontic file to the apical foramen, and actual lengths were determined by reducing 0.5 mm from this length. The statistical analysis was performed by one-way ANOVA test and Tukey-HSD post hoc procedure. P < 0.05 was considered as significant. RESULTS: No significant difference was found between overall mean electronic working length and digital radiographic length; however, prediction error (P < 0.05) was significant with respect to different irrigants. Among the irrigating solutions, chlorhexidine gluconate had the smallest distance to the actual lengths, whereas NaOCl had the greatest. CONCLUSION: Electronic apex locator ProPex yielded best result in the presence of chlorhexidine, whereas the largest error was demonstrated with NaOCl indicating that higher electroconductive irrigating solutions affect the precision of multi-frequency apex locators. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC3955316/ /pubmed/24688561 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Khursheed, Irfana Bansal, Ruchika Bansal, Tajinder Singh, Harkanwal Preet Yadav, Madhulika Reddy, K. Jetender A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study |
title | A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study |
title_full | A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study |
title_fullStr | A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study |
title_full_unstemmed | A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study |
title_short | A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study |
title_sort | comparative evaluation of working length with digital radiography and third generation apex locator (propex) in the presence of various intracanal irrigants: an in vivo/ex vivo study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955316/ https://www.ncbi.nlm.nih.gov/pubmed/24688561 |
work_keys_str_mv | AT khursheedirfana acomparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT bansalruchika acomparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT bansaltajinder acomparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT singhharkanwalpreet acomparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT yadavmadhulika acomparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT reddykjetender acomparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT khursheedirfana comparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT bansalruchika comparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT bansaltajinder comparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT singhharkanwalpreet comparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT yadavmadhulika comparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy AT reddykjetender comparativeevaluationofworkinglengthwithdigitalradiographyandthirdgenerationapexlocatorpropexinthepresenceofvariousintracanalirrigantsaninvivoexvivostudy |