Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study

Objective: The aim of this study was to compare clinical screening tests (modified Mallampati score, Cormack-Lehane score, thyromental distance, and sternomental distance) with ultrasonic measurements of the upper airway in predicting difficult intubation in pregnant women whose Body Mass Index (BMI...

Descripción completa

Detalles Bibliográficos
Autores principales: Turkay Aydogmus, Meltem, Erkalp, Kerem, Nadir Sinikoglu, Sitki, A. Usta, Taner, O. Ulger, Gunes, Alagol, Aysin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publicaitons 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955549/
https://www.ncbi.nlm.nih.gov/pubmed/24639838
http://dx.doi.org/10.12669/pjms.301.3972
_version_ 1782307583924633600
author Turkay Aydogmus, Meltem
Erkalp, Kerem
Nadir Sinikoglu, Sitki
A. Usta, Taner
O. Ulger, Gunes
Alagol, Aysin
author_facet Turkay Aydogmus, Meltem
Erkalp, Kerem
Nadir Sinikoglu, Sitki
A. Usta, Taner
O. Ulger, Gunes
Alagol, Aysin
author_sort Turkay Aydogmus, Meltem
collection PubMed
description Objective: The aim of this study was to compare clinical screening tests (modified Mallampati score, Cormack-Lehane score, thyromental distance, and sternomental distance) with ultrasonic measurements of the upper airway in predicting difficult intubation in pregnant women whose Body Mass Index (BMI) is higher and lower than 30 kg m-2. Methods: This study was designed as a prospective observational trial, and consisted of 40 pregnant women of American Society of Anesthesiologists (ASA) 1-2 groups. Patients with a BMI lower than 30 kg m-2 were included in Group 1 (n=20), and patients with a BMI higher than 30 kg m-2 were included in Group 2 (n=20). In the supine position with head in mild extension, the diameter of the transverse tracheal air shadow in the subglottic area of the front neck was measured using ultrasonography. Modified Mallampati score, Cormack-Lehane score, thyromental distance and sternomental distance measurements were recorded. Results: No statistically significant difference was detected between groups regarding mean age, mean number of pregnancy, ASA scores and comorbid disease. Mean body weight (p=0.0001) and mean pre-pregnancy weight (p=0.0001) were significantly higher in Group 2. There was no statistically significant difference between groups regarding mean modified Mallampati score, thyromental distance, sternomental distance measurements, Cormack-Lehane score, and mean ultrasonic measurements. Conclusion: It was found that BMI higher or lower than 30 kg m-2 has no effect on ultrasonic measurements and clinical airway tests. We thought that ultrasonic measurement could not give us valuable information in obese or non-obese pregnant women.
format Online
Article
Text
id pubmed-3955549
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Professional Medical Publicaitons
record_format MEDLINE/PubMed
spelling pubmed-39555492014-03-17 Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study Turkay Aydogmus, Meltem Erkalp, Kerem Nadir Sinikoglu, Sitki A. Usta, Taner O. Ulger, Gunes Alagol, Aysin Pak J Med Sci Original Article Objective: The aim of this study was to compare clinical screening tests (modified Mallampati score, Cormack-Lehane score, thyromental distance, and sternomental distance) with ultrasonic measurements of the upper airway in predicting difficult intubation in pregnant women whose Body Mass Index (BMI) is higher and lower than 30 kg m-2. Methods: This study was designed as a prospective observational trial, and consisted of 40 pregnant women of American Society of Anesthesiologists (ASA) 1-2 groups. Patients with a BMI lower than 30 kg m-2 were included in Group 1 (n=20), and patients with a BMI higher than 30 kg m-2 were included in Group 2 (n=20). In the supine position with head in mild extension, the diameter of the transverse tracheal air shadow in the subglottic area of the front neck was measured using ultrasonography. Modified Mallampati score, Cormack-Lehane score, thyromental distance and sternomental distance measurements were recorded. Results: No statistically significant difference was detected between groups regarding mean age, mean number of pregnancy, ASA scores and comorbid disease. Mean body weight (p=0.0001) and mean pre-pregnancy weight (p=0.0001) were significantly higher in Group 2. There was no statistically significant difference between groups regarding mean modified Mallampati score, thyromental distance, sternomental distance measurements, Cormack-Lehane score, and mean ultrasonic measurements. Conclusion: It was found that BMI higher or lower than 30 kg m-2 has no effect on ultrasonic measurements and clinical airway tests. We thought that ultrasonic measurement could not give us valuable information in obese or non-obese pregnant women. Professional Medical Publicaitons 2014 /pmc/articles/PMC3955549/ /pubmed/24639838 http://dx.doi.org/10.12669/pjms.301.3972 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Turkay Aydogmus, Meltem
Erkalp, Kerem
Nadir Sinikoglu, Sitki
A. Usta, Taner
O. Ulger, Gunes
Alagol, Aysin
Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study
title Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study
title_full Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study
title_fullStr Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study
title_full_unstemmed Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study
title_short Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: A prospective comparative study
title_sort is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: a prospective comparative study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955549/
https://www.ncbi.nlm.nih.gov/pubmed/24639838
http://dx.doi.org/10.12669/pjms.301.3972
work_keys_str_mv AT turkayaydogmusmeltem isultrasonicinvestigationoftransversetrachealairshadowdiameterreasonableforevaluationofdifficultairwayinpregnantwomenaprospectivecomparativestudy
AT erkalpkerem isultrasonicinvestigationoftransversetrachealairshadowdiameterreasonableforevaluationofdifficultairwayinpregnantwomenaprospectivecomparativestudy
AT nadirsinikoglusitki isultrasonicinvestigationoftransversetrachealairshadowdiameterreasonableforevaluationofdifficultairwayinpregnantwomenaprospectivecomparativestudy
AT austataner isultrasonicinvestigationoftransversetrachealairshadowdiameterreasonableforevaluationofdifficultairwayinpregnantwomenaprospectivecomparativestudy
AT oulgergunes isultrasonicinvestigationoftransversetrachealairshadowdiameterreasonableforevaluationofdifficultairwayinpregnantwomenaprospectivecomparativestudy
AT alagolaysin isultrasonicinvestigationoftransversetrachealairshadowdiameterreasonableforevaluationofdifficultairwayinpregnantwomenaprospectivecomparativestudy