Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency
OBJECTIVE: To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. MATERIALS AND METHODS: Thirty-three ablation zones were created in nine pigs using a DS system a...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955790/ https://www.ncbi.nlm.nih.gov/pubmed/24643383 http://dx.doi.org/10.3348/kjr.2014.15.2.235 |
_version_ | 1782307624216166400 |
---|---|
author | Yoon, Jeong Hee Lee, Jeong Min Hwang, Eui Jin Hwang, In Pyung Baek, Jeehyun Han, Joon Koo Choi, Byung Ihn |
author_facet | Yoon, Jeong Hee Lee, Jeong Min Hwang, Eui Jin Hwang, In Pyung Baek, Jeehyun Han, Joon Koo Choi, Byung Ihn |
author_sort | Yoon, Jeong Hee |
collection | PubMed |
description | OBJECTIVE: To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. MATERIALS AND METHODS: Thirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups. RESULTS: No pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 ± 4.0 kcal vs. 16.92 ± 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 ± 16.4 cm(3) vs. 20.8 ± 10.7 cm(3); p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29). CONCLUSION: Dual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time. |
format | Online Article Text |
id | pubmed-3955790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-39557902014-03-18 Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency Yoon, Jeong Hee Lee, Jeong Min Hwang, Eui Jin Hwang, In Pyung Baek, Jeehyun Han, Joon Koo Choi, Byung Ihn Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. MATERIALS AND METHODS: Thirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups. RESULTS: No pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 ± 4.0 kcal vs. 16.92 ± 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 ± 16.4 cm(3) vs. 20.8 ± 10.7 cm(3); p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29). CONCLUSION: Dual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time. The Korean Society of Radiology 2014 2014-03-07 /pmc/articles/PMC3955790/ /pubmed/24643383 http://dx.doi.org/10.3348/kjr.2014.15.2.235 Text en Copyright © 2014 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Gastrointestinal Imaging Yoon, Jeong Hee Lee, Jeong Min Hwang, Eui Jin Hwang, In Pyung Baek, Jeehyun Han, Joon Koo Choi, Byung Ihn Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency |
title | Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency |
title_full | Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency |
title_fullStr | Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency |
title_full_unstemmed | Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency |
title_short | Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency |
title_sort | monopolar radiofrequency ablation using a dual-switching system and a separable clustered electrode: evaluation of the in vivo efficiency |
topic | Gastrointestinal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3955790/ https://www.ncbi.nlm.nih.gov/pubmed/24643383 http://dx.doi.org/10.3348/kjr.2014.15.2.235 |
work_keys_str_mv | AT yoonjeonghee monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency AT leejeongmin monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency AT hwangeuijin monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency AT hwanginpyung monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency AT baekjeehyun monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency AT hanjoonkoo monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency AT choibyungihn monopolarradiofrequencyablationusingadualswitchingsystemandaseparableclusteredelectrodeevaluationoftheinvivoefficiency |