Cargando…

Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations

BACKGROUND: Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO(2)), and haemoglobin saturation (SaO(2)), are the indices used in clinical assessments,...

Descripción completa

Detalles Bibliográficos
Autores principales: Santhirapala, Vatshalan, Williams, Louisa C., Tighe, Hannah C., Jackson, James E., Shovlin, Claire L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3956463/
https://www.ncbi.nlm.nih.gov/pubmed/24637882
http://dx.doi.org/10.1371/journal.pone.0090777
_version_ 1782307670290595840
author Santhirapala, Vatshalan
Williams, Louisa C.
Tighe, Hannah C.
Jackson, James E.
Shovlin, Claire L.
author_facet Santhirapala, Vatshalan
Williams, Louisa C.
Tighe, Hannah C.
Jackson, James E.
Shovlin, Claire L.
author_sort Santhirapala, Vatshalan
collection PubMed
description BACKGROUND: Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO(2)), and haemoglobin saturation (SaO(2)), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity. METHODOLOGY: 165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO(2) x haemoglobin x 1.34/100. PRINCIPAL FINDINGS: There was wide variation in SaO(2) on air (78.5–99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO(2) explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO(2) but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO(2) and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO(2), but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up. SIGNIFICANCE: Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content per unit blood volume. This can be maintained for SaO(2) ≥78.5%, and resets to the same arterial oxygen content after correction of hypoxaemia. Serum iron concentrations, not ferritin, seem to predict more successful polycythaemic responses.
format Online
Article
Text
id pubmed-3956463
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-39564632014-03-18 Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations Santhirapala, Vatshalan Williams, Louisa C. Tighe, Hannah C. Jackson, James E. Shovlin, Claire L. PLoS One Research Article BACKGROUND: Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO(2)), and haemoglobin saturation (SaO(2)), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity. METHODOLOGY: 165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO(2) x haemoglobin x 1.34/100. PRINCIPAL FINDINGS: There was wide variation in SaO(2) on air (78.5–99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO(2) explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO(2) but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO(2) and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO(2), but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up. SIGNIFICANCE: Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content per unit blood volume. This can be maintained for SaO(2) ≥78.5%, and resets to the same arterial oxygen content after correction of hypoxaemia. Serum iron concentrations, not ferritin, seem to predict more successful polycythaemic responses. Public Library of Science 2014-03-17 /pmc/articles/PMC3956463/ /pubmed/24637882 http://dx.doi.org/10.1371/journal.pone.0090777 Text en © 2014 Santhirapala et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Santhirapala, Vatshalan
Williams, Louisa C.
Tighe, Hannah C.
Jackson, James E.
Shovlin, Claire L.
Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations
title Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations
title_full Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations
title_fullStr Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations
title_full_unstemmed Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations
title_short Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations
title_sort arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3956463/
https://www.ncbi.nlm.nih.gov/pubmed/24637882
http://dx.doi.org/10.1371/journal.pone.0090777
work_keys_str_mv AT santhirapalavatshalan arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT williamslouisac arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT tighehannahc arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT jacksonjamese arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT shovlinclairel arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations