Cargando…
256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality
PURPOSE: The objective of this study is to assess the effect of heart rate, heart rate variability and z-axis location on coronary artery bypass graft (CABG) image quality using a 256-slice computed tomography (CT) scanner. METHODS: A total of 78 patients with 254 CABG (762 graft segments) were recr...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3956757/ https://www.ncbi.nlm.nih.gov/pubmed/24637891 http://dx.doi.org/10.1371/journal.pone.0091861 |
_version_ | 1782307707955445760 |
---|---|
author | Gramer, Bettina M. Diez Martinez, Patricia Chin, Anne S. Sylvestre, Marie-Pierre Larrivée, Sandra Stevens, Louis-Mathieu Noiseux, Nicolas Soulez, Gilles Rummeny, Ernst J. Chartrand-Lefebvre, Carl |
author_facet | Gramer, Bettina M. Diez Martinez, Patricia Chin, Anne S. Sylvestre, Marie-Pierre Larrivée, Sandra Stevens, Louis-Mathieu Noiseux, Nicolas Soulez, Gilles Rummeny, Ernst J. Chartrand-Lefebvre, Carl |
author_sort | Gramer, Bettina M. |
collection | PubMed |
description | PURPOSE: The objective of this study is to assess the effect of heart rate, heart rate variability and z-axis location on coronary artery bypass graft (CABG) image quality using a 256-slice computed tomography (CT) scanner. METHODS: A total of 78 patients with 254 CABG (762 graft segments) were recruited to undergo CABG assessment with 256-slice CT and prospective ECG-gating. Two observers rated graft segments for image quality on a 5-point scale. Quantitative measurements were also made. Logistic and cumulative link mixed models were used to assess the predictors of graft image quality. RESULTS: Graft image quality was judged as diagnostic (scores 5 (excellent), 4 (good) and 3 (moderate)) in 96.6% of the 762 segments. Interobserver agreement was excellent (kappa ≥0.90). Graft image quality was not affected by heart rate level. However, high heart rate variability was associated with an important and significant image quality deterioration (odds ratio 4.31; p = 0.036). Distal graft segments had significantly lower image quality scores than proximal segments (p ≤ 0.02). Significantly higher noise was noted at the origin of the mammary grafts (p = 0.001), owing to streak artifacts from the shoulders. CONCLUSION: CABG imaging with 270-msec rotation 256-slice CT and prospective ECG-gating showed an adequate image quality in 96.6% of graft segments, and an excellent interobserver agreement. Graft image quality was not influenced by heart rate level. Image quality scores were however significantly decreased in patients with high heart rate variability, as well as in distal graft segments, which are closer to the heart. |
format | Online Article Text |
id | pubmed-3956757 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39567572014-03-18 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality Gramer, Bettina M. Diez Martinez, Patricia Chin, Anne S. Sylvestre, Marie-Pierre Larrivée, Sandra Stevens, Louis-Mathieu Noiseux, Nicolas Soulez, Gilles Rummeny, Ernst J. Chartrand-Lefebvre, Carl PLoS One Research Article PURPOSE: The objective of this study is to assess the effect of heart rate, heart rate variability and z-axis location on coronary artery bypass graft (CABG) image quality using a 256-slice computed tomography (CT) scanner. METHODS: A total of 78 patients with 254 CABG (762 graft segments) were recruited to undergo CABG assessment with 256-slice CT and prospective ECG-gating. Two observers rated graft segments for image quality on a 5-point scale. Quantitative measurements were also made. Logistic and cumulative link mixed models were used to assess the predictors of graft image quality. RESULTS: Graft image quality was judged as diagnostic (scores 5 (excellent), 4 (good) and 3 (moderate)) in 96.6% of the 762 segments. Interobserver agreement was excellent (kappa ≥0.90). Graft image quality was not affected by heart rate level. However, high heart rate variability was associated with an important and significant image quality deterioration (odds ratio 4.31; p = 0.036). Distal graft segments had significantly lower image quality scores than proximal segments (p ≤ 0.02). Significantly higher noise was noted at the origin of the mammary grafts (p = 0.001), owing to streak artifacts from the shoulders. CONCLUSION: CABG imaging with 270-msec rotation 256-slice CT and prospective ECG-gating showed an adequate image quality in 96.6% of graft segments, and an excellent interobserver agreement. Graft image quality was not influenced by heart rate level. Image quality scores were however significantly decreased in patients with high heart rate variability, as well as in distal graft segments, which are closer to the heart. Public Library of Science 2014-03-17 /pmc/articles/PMC3956757/ /pubmed/24637891 http://dx.doi.org/10.1371/journal.pone.0091861 Text en © 2014 Gramer et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Gramer, Bettina M. Diez Martinez, Patricia Chin, Anne S. Sylvestre, Marie-Pierre Larrivée, Sandra Stevens, Louis-Mathieu Noiseux, Nicolas Soulez, Gilles Rummeny, Ernst J. Chartrand-Lefebvre, Carl 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality |
title | 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality |
title_full | 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality |
title_fullStr | 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality |
title_full_unstemmed | 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality |
title_short | 256-Slice CT Angiographic Evaluation of Coronary Artery Bypass Grafts: Effect of Heart Rate, Heart Rate Variability and Z-Axis Location on Image Quality |
title_sort | 256-slice ct angiographic evaluation of coronary artery bypass grafts: effect of heart rate, heart rate variability and z-axis location on image quality |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3956757/ https://www.ncbi.nlm.nih.gov/pubmed/24637891 http://dx.doi.org/10.1371/journal.pone.0091861 |
work_keys_str_mv | AT gramerbettinam 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT diezmartinezpatricia 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT chinannes 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT sylvestremariepierre 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT larriveesandra 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT stevenslouismathieu 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT noiseuxnicolas 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT soulezgilles 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT rummenyernstj 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality AT chartrandlefebvrecarl 256slicectangiographicevaluationofcoronaryarterybypassgraftseffectofheartrateheartratevariabilityandzaxislocationonimagequality |