Cargando…

An Algorithm for Glaucoma Screening in Clinical Settings and Its Preliminary Performance Profile

PURPOSE: To devise and evaluate a screening algorithm for glaucoma in clinical settings. METHODS: Screening included examination of the optic disc for vertical cupping (≥0.4) and asymmetry (≥0.15), Goldmann applanation tonometry (≥21 mmHg, adjusted or unadjusted for central corneal thickness), and a...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammadi, S-Farzad, Mirhadi, Sara, Mehrjardi, Hadi Z., Fotouhi, Akbar, Taba Taba Vakili, Sahar, Majdi, Mercede, Moghimi, Sasan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ophthalmic Research Center 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3957037/
https://www.ncbi.nlm.nih.gov/pubmed/24653818

Ejemplares similares