Magnetic Sensor for Building Structural Vibrations
This paper shows a new displacement-to-frequency transducer based on the variation of a coil inductance when a magnetic core is partially or completely inserted inside. This transducer is based on a Colpitts oscillator due its low manufacturing price, behavior and immunity to noise. A tank circuit w...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958254/ https://www.ncbi.nlm.nih.gov/pubmed/24504104 http://dx.doi.org/10.3390/s140202468 |
_version_ | 1782307835704508416 |
---|---|
author | García, Alfonso Morón, Carlos Tremps, Enrique |
author_facet | García, Alfonso Morón, Carlos Tremps, Enrique |
author_sort | García, Alfonso |
collection | PubMed |
description | This paper shows a new displacement-to-frequency transducer based on the variation of a coil inductance when a magnetic core is partially or completely inserted inside. This transducer is based on a Colpitts oscillator due its low manufacturing price, behavior and immunity to noise. A tank circuit with a configuration in parallel was used because it can be employed at lower frequencies and it enables it to make a direct analysis. The sensor has a dynamic range equal to the length of the coil. The cores can exchange sensors (coils with its ferromagnetic core) using the same electronic measuring system. In this way, with only an electronic circuit, the core sensor determines the measurement range. The obtained resolution is higher than 1/100,000, and the sensor also allows the measurement and knowing in real time the effect of vibration, thermal expansion, referred overload movements, etc.., that can occur in the structural elements of a building. |
format | Online Article Text |
id | pubmed-3958254 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-39582542014-03-20 Magnetic Sensor for Building Structural Vibrations García, Alfonso Morón, Carlos Tremps, Enrique Sensors (Basel) Article This paper shows a new displacement-to-frequency transducer based on the variation of a coil inductance when a magnetic core is partially or completely inserted inside. This transducer is based on a Colpitts oscillator due its low manufacturing price, behavior and immunity to noise. A tank circuit with a configuration in parallel was used because it can be employed at lower frequencies and it enables it to make a direct analysis. The sensor has a dynamic range equal to the length of the coil. The cores can exchange sensors (coils with its ferromagnetic core) using the same electronic measuring system. In this way, with only an electronic circuit, the core sensor determines the measurement range. The obtained resolution is higher than 1/100,000, and the sensor also allows the measurement and knowing in real time the effect of vibration, thermal expansion, referred overload movements, etc.., that can occur in the structural elements of a building. Molecular Diversity Preservation International (MDPI) 2014-02-05 /pmc/articles/PMC3958254/ /pubmed/24504104 http://dx.doi.org/10.3390/s140202468 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article García, Alfonso Morón, Carlos Tremps, Enrique Magnetic Sensor for Building Structural Vibrations |
title | Magnetic Sensor for Building Structural Vibrations |
title_full | Magnetic Sensor for Building Structural Vibrations |
title_fullStr | Magnetic Sensor for Building Structural Vibrations |
title_full_unstemmed | Magnetic Sensor for Building Structural Vibrations |
title_short | Magnetic Sensor for Building Structural Vibrations |
title_sort | magnetic sensor for building structural vibrations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958254/ https://www.ncbi.nlm.nih.gov/pubmed/24504104 http://dx.doi.org/10.3390/s140202468 |
work_keys_str_mv | AT garciaalfonso magneticsensorforbuildingstructuralvibrations AT moroncarlos magneticsensorforbuildingstructuralvibrations AT trempsenrique magneticsensorforbuildingstructuralvibrations |