Cargando…

Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements

PURPOSE: To quantify the effects of using the fovea to Bruch's membrane opening (FoBMO) axis as the nasal-temporal midline for 30° sectoral (clock-hour) spectral domain optical coherence tomography (SDOCT) optic nerve head (ONH) minimum rim width (MRW) and area (MRA) calculations. METHODS: The...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Lin, Ren, Ruojin, Yang, Hongli, Hardin, Christy, Reyes, Luke, Reynaud, Juan, Gardiner, Stuart K., Fortune, Brad, Demirel, Shaban, Burgoyne, Claude F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958478/
https://www.ncbi.nlm.nih.gov/pubmed/24643069
http://dx.doi.org/10.1371/journal.pone.0092225
_version_ 1782307878319685632
author He, Lin
Ren, Ruojin
Yang, Hongli
Hardin, Christy
Reyes, Luke
Reynaud, Juan
Gardiner, Stuart K.
Fortune, Brad
Demirel, Shaban
Burgoyne, Claude F.
author_facet He, Lin
Ren, Ruojin
Yang, Hongli
Hardin, Christy
Reyes, Luke
Reynaud, Juan
Gardiner, Stuart K.
Fortune, Brad
Demirel, Shaban
Burgoyne, Claude F.
author_sort He, Lin
collection PubMed
description PURPOSE: To quantify the effects of using the fovea to Bruch's membrane opening (FoBMO) axis as the nasal-temporal midline for 30° sectoral (clock-hour) spectral domain optical coherence tomography (SDOCT) optic nerve head (ONH) minimum rim width (MRW) and area (MRA) calculations. METHODS: The internal limiting membrane and BMO were delineated within 24 radial ONH B-scans in 222 eyes of 222 participants with ocular hypertension and glaucoma. For each eye the fovea was marked within the infrared reflectance image, the FoBMO angle (θ) relative to the acquired image frame (AIF) horizontal was calculated, the ONH was divided into 30°sectors using a FoBMO or AIF nasal/temporal axis, and SDOCT MRW and MRA were quantified within each FoBMO vs. AIF sector. For each sector, focal rim loss was calculated as the MRW and MRA gradients (i.e. the difference between the value for that sector and the one clockwise to it divided by 30°). Sectoral FoBMO vs. AIF discordance was calculated as the difference between the FoBMO and AIF values for each sector. Generalized estimating equations were used to predict the eyes and sectors of maximum FoBMO vs. AIF discordance. RESULTS: The mean FoBMO angle was −6.6±4.2° (range: −17° to +7°). FoBMO vs. AIF discordance in sectoral mean MRW and MRA was significant for 7 of 12 and 6 of 12 sectors, respectively (p<0.05, Wilcoxon test, Bonferroni correction). Eye-specific, FoBMO vs. AIF sectoral discordance was predicted by sectoral rim gradient (p<0.001) and FoBMO angle (p<0.001) and achieved maximum values of 83% for MRW and 101% for MRA. CONCLUSIONS: Using the FoBMO axis as the nasal-temporal axis to regionalize the ONH rather than a line parallel to the AIF horizontal axis significantly influences clock-hour SDOCT rim values. This effect is greatest in eyes with large FoBMO angles and sectors with focal rim loss.
format Online
Article
Text
id pubmed-3958478
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-39584782014-03-24 Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements He, Lin Ren, Ruojin Yang, Hongli Hardin, Christy Reyes, Luke Reynaud, Juan Gardiner, Stuart K. Fortune, Brad Demirel, Shaban Burgoyne, Claude F. PLoS One Research Article PURPOSE: To quantify the effects of using the fovea to Bruch's membrane opening (FoBMO) axis as the nasal-temporal midline for 30° sectoral (clock-hour) spectral domain optical coherence tomography (SDOCT) optic nerve head (ONH) minimum rim width (MRW) and area (MRA) calculations. METHODS: The internal limiting membrane and BMO were delineated within 24 radial ONH B-scans in 222 eyes of 222 participants with ocular hypertension and glaucoma. For each eye the fovea was marked within the infrared reflectance image, the FoBMO angle (θ) relative to the acquired image frame (AIF) horizontal was calculated, the ONH was divided into 30°sectors using a FoBMO or AIF nasal/temporal axis, and SDOCT MRW and MRA were quantified within each FoBMO vs. AIF sector. For each sector, focal rim loss was calculated as the MRW and MRA gradients (i.e. the difference between the value for that sector and the one clockwise to it divided by 30°). Sectoral FoBMO vs. AIF discordance was calculated as the difference between the FoBMO and AIF values for each sector. Generalized estimating equations were used to predict the eyes and sectors of maximum FoBMO vs. AIF discordance. RESULTS: The mean FoBMO angle was −6.6±4.2° (range: −17° to +7°). FoBMO vs. AIF discordance in sectoral mean MRW and MRA was significant for 7 of 12 and 6 of 12 sectors, respectively (p<0.05, Wilcoxon test, Bonferroni correction). Eye-specific, FoBMO vs. AIF sectoral discordance was predicted by sectoral rim gradient (p<0.001) and FoBMO angle (p<0.001) and achieved maximum values of 83% for MRW and 101% for MRA. CONCLUSIONS: Using the FoBMO axis as the nasal-temporal axis to regionalize the ONH rather than a line parallel to the AIF horizontal axis significantly influences clock-hour SDOCT rim values. This effect is greatest in eyes with large FoBMO angles and sectors with focal rim loss. Public Library of Science 2014-03-18 /pmc/articles/PMC3958478/ /pubmed/24643069 http://dx.doi.org/10.1371/journal.pone.0092225 Text en © 2014 He et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
He, Lin
Ren, Ruojin
Yang, Hongli
Hardin, Christy
Reyes, Luke
Reynaud, Juan
Gardiner, Stuart K.
Fortune, Brad
Demirel, Shaban
Burgoyne, Claude F.
Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements
title Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements
title_full Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements
title_fullStr Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements
title_full_unstemmed Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements
title_short Anatomic vs. Acquired Image Frame Discordance in Spectral Domain Optical Coherence Tomography Minimum Rim Measurements
title_sort anatomic vs. acquired image frame discordance in spectral domain optical coherence tomography minimum rim measurements
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958478/
https://www.ncbi.nlm.nih.gov/pubmed/24643069
http://dx.doi.org/10.1371/journal.pone.0092225
work_keys_str_mv AT helin anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT renruojin anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT yanghongli anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT hardinchristy anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT reyesluke anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT reynaudjuan anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT gardinerstuartk anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT fortunebrad anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT demirelshaban anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements
AT burgoyneclaudef anatomicvsacquiredimageframediscordanceinspectraldomainopticalcoherencetomographyminimumrimmeasurements