Cargando…

Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions

Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth su...

Descripción completa

Detalles Bibliográficos
Autores principales: Svanborg, Per, Skjerven, Henrik, Carlsson, Pablo, Eliasson, Alf, Karlsson, Stig, Örtorp, Anders
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958727/
https://www.ncbi.nlm.nih.gov/pubmed/24723954
http://dx.doi.org/10.1155/2014/534382
_version_ 1782307929144164352
author Svanborg, Per
Skjerven, Henrik
Carlsson, Pablo
Eliasson, Alf
Karlsson, Stig
Örtorp, Anders
author_facet Svanborg, Per
Skjerven, Henrik
Carlsson, Pablo
Eliasson, Alf
Karlsson, Stig
Örtorp, Anders
author_sort Svanborg, Per
collection PubMed
description Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS) impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results. Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147 μm and 142 μm, cervical area discrepancy of 69 μm and 44 μm, and mean internal discrepancy of 117 μm and 93 μm. The differences were statistically significant in the cervical and internal areas (P < 0.001). Significance. The results indicated that the digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique.
format Online
Article
Text
id pubmed-3958727
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-39587272014-04-10 Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions Svanborg, Per Skjerven, Henrik Carlsson, Pablo Eliasson, Alf Karlsson, Stig Örtorp, Anders Int J Dent Research Article Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS) impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results. Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147 μm and 142 μm, cervical area discrepancy of 69 μm and 44 μm, and mean internal discrepancy of 117 μm and 93 μm. The differences were statistically significant in the cervical and internal areas (P < 0.001). Significance. The results indicated that the digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique. Hindawi Publishing Corporation 2014 2014-03-03 /pmc/articles/PMC3958727/ /pubmed/24723954 http://dx.doi.org/10.1155/2014/534382 Text en Copyright © 2014 Per Svanborg et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Svanborg, Per
Skjerven, Henrik
Carlsson, Pablo
Eliasson, Alf
Karlsson, Stig
Örtorp, Anders
Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
title Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
title_full Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
title_fullStr Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
title_full_unstemmed Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
title_short Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
title_sort marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958727/
https://www.ncbi.nlm.nih.gov/pubmed/24723954
http://dx.doi.org/10.1155/2014/534382
work_keys_str_mv AT svanborgper marginalandinternalfitofcobaltchromiumfixeddentalprosthesesgeneratedfromdigitalandconventionalimpressions
AT skjervenhenrik marginalandinternalfitofcobaltchromiumfixeddentalprosthesesgeneratedfromdigitalandconventionalimpressions
AT carlssonpablo marginalandinternalfitofcobaltchromiumfixeddentalprosthesesgeneratedfromdigitalandconventionalimpressions
AT eliassonalf marginalandinternalfitofcobaltchromiumfixeddentalprosthesesgeneratedfromdigitalandconventionalimpressions
AT karlssonstig marginalandinternalfitofcobaltchromiumfixeddentalprosthesesgeneratedfromdigitalandconventionalimpressions
AT ortorpanders marginalandinternalfitofcobaltchromiumfixeddentalprosthesesgeneratedfromdigitalandconventionalimpressions