Cargando…
Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma
This study was performed to evaluate dosimetric differences between current intensity modulated radiation therapy (IMRT) delivery modes: Step-and-shoot (SS), sliding window (SW), and volumetric modulated arc therapy (VMAT). Plans for 15 prostate cancer patients with 10 MV photon beams using each IMR...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958995/ https://www.ncbi.nlm.nih.gov/pubmed/24672150 http://dx.doi.org/10.4103/0971-6203.121193 |
_version_ | 1782307979858542592 |
---|---|
author | Herman, Tania De La Fuente Schnell, Erich Young, Julie Hildebrand, Kim Algan, Özer Syzek, Elizabeth Herman, Terence Ahmad, Salahuddin |
author_facet | Herman, Tania De La Fuente Schnell, Erich Young, Julie Hildebrand, Kim Algan, Özer Syzek, Elizabeth Herman, Terence Ahmad, Salahuddin |
author_sort | Herman, Tania De La Fuente |
collection | PubMed |
description | This study was performed to evaluate dosimetric differences between current intensity modulated radiation therapy (IMRT) delivery modes: Step-and-shoot (SS), sliding window (SW), and volumetric modulated arc therapy (VMAT). Plans for 15 prostate cancer patients with 10 MV photon beams using each IMRT mode were generated. Patients had three planning target volumes (PTVs) including prostate, prostate plus seminal vesicles, and pelvic lymphatics. Dose volume histograms (DVHs) of PTVs and organs at risk (OARs), tumor control probability (TCP) and normal tissue complication probabilities (NTCPs), conformation number, and monitor units (MUs) used were compared. Statistical analysis was performed using the analysis of variance (ANOVA) technique. The TCPs were < 99% with insignificant differences among modalities (P > 0.99). Doses to all critical structures were higher on average with SW method compared to SS, but insignificant. NTCP values were lowest for VMAT in all structures excepting bladder. Normal tissue volumes receiving doses in the 20-30 Gy range were reduced for VMAT compared to SS. Percentage of MUs required for VMAT to deliver a comparable plan to SS and SW was at least 40% less. In conclusion, similar target coverage and normal tissue doses were found by the three compared modes and the dosimetric differences were small. |
format | Online Article Text |
id | pubmed-3958995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-39589952014-03-26 Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma Herman, Tania De La Fuente Schnell, Erich Young, Julie Hildebrand, Kim Algan, Özer Syzek, Elizabeth Herman, Terence Ahmad, Salahuddin J Med Phys Original Article This study was performed to evaluate dosimetric differences between current intensity modulated radiation therapy (IMRT) delivery modes: Step-and-shoot (SS), sliding window (SW), and volumetric modulated arc therapy (VMAT). Plans for 15 prostate cancer patients with 10 MV photon beams using each IMRT mode were generated. Patients had three planning target volumes (PTVs) including prostate, prostate plus seminal vesicles, and pelvic lymphatics. Dose volume histograms (DVHs) of PTVs and organs at risk (OARs), tumor control probability (TCP) and normal tissue complication probabilities (NTCPs), conformation number, and monitor units (MUs) used were compared. Statistical analysis was performed using the analysis of variance (ANOVA) technique. The TCPs were < 99% with insignificant differences among modalities (P > 0.99). Doses to all critical structures were higher on average with SW method compared to SS, but insignificant. NTCP values were lowest for VMAT in all structures excepting bladder. Normal tissue volumes receiving doses in the 20-30 Gy range were reduced for VMAT compared to SS. Percentage of MUs required for VMAT to deliver a comparable plan to SS and SW was at least 40% less. In conclusion, similar target coverage and normal tissue doses were found by the three compared modes and the dosimetric differences were small. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3958995/ /pubmed/24672150 http://dx.doi.org/10.4103/0971-6203.121193 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Herman, Tania De La Fuente Schnell, Erich Young, Julie Hildebrand, Kim Algan, Özer Syzek, Elizabeth Herman, Terence Ahmad, Salahuddin Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
title | Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
title_full | Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
title_fullStr | Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
title_full_unstemmed | Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
title_short | Dosimetric comparison between IMRT delivery modes: Step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
title_sort | dosimetric comparison between imrt delivery modes: step-and-shoot, sliding window, and volumetric modulated arc therapy — for whole pelvis radiation therapy of intermediate-to-high risk prostate adenocarcinoma |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958995/ https://www.ncbi.nlm.nih.gov/pubmed/24672150 http://dx.doi.org/10.4103/0971-6203.121193 |
work_keys_str_mv | AT hermantaniadelafuente dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT schnellerich dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT youngjulie dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT hildebrandkim dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT alganozer dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT syzekelizabeth dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT hermanterence dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma AT ahmadsalahuddin dosimetriccomparisonbetweenimrtdeliverymodesstepandshootslidingwindowandvolumetricmodulatedarctherapyforwholepelvisradiationtherapyofintermediatetohighriskprostateadenocarcinoma |