Cargando…
Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
Compton-scattered photons included within the photopeak pulse-height window result in the degradation of SPECT images both qualitatively and quantitatively. The purpose of this study is to evaluate and compare six scatter correction methods based on setting the energy windows in (99m)Tc spectrum. SI...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958999/ https://www.ncbi.nlm.nih.gov/pubmed/24672154 http://dx.doi.org/10.4103/0971-6203.121197 |
_version_ | 1782307980776046592 |
---|---|
author | Asl, Mahsa Noori Sadremomtaz, Alireza Bitarafan-Rajabi, Ahmad |
author_facet | Asl, Mahsa Noori Sadremomtaz, Alireza Bitarafan-Rajabi, Ahmad |
author_sort | Asl, Mahsa Noori |
collection | PubMed |
description | Compton-scattered photons included within the photopeak pulse-height window result in the degradation of SPECT images both qualitatively and quantitatively. The purpose of this study is to evaluate and compare six scatter correction methods based on setting the energy windows in (99m)Tc spectrum. SIMIND Monte Carlo simulation is used to generate the projection images from a cold-sphere hot-background phantom. For evaluation of different scatter correction methods, three assessment criteria including image contrast, signal-to-noise ratio (SNR) and relative noise of the background (RNB) are considered. Except for the dual-photopeak window (DPW) method, the image contrast of the five cold spheres is improved in the range of 2.7-26%. Among methods considered, two methods show a nonuniform correction performance. The RNB for all of the scatter correction methods is ranged from minimum 0.03 for DPW method to maximum 0.0727 for the three energy window (TEW) method using trapezoidal approximation. The TEW method using triangular approximation because of ease of implementation, good improvement of the image contrast and the SNR for the five cold spheres, and the low noise level is proposed as most appropriate correction method. |
format | Online Article Text |
id | pubmed-3958999 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-39589992014-03-26 Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation Asl, Mahsa Noori Sadremomtaz, Alireza Bitarafan-Rajabi, Ahmad J Med Phys Original Article Compton-scattered photons included within the photopeak pulse-height window result in the degradation of SPECT images both qualitatively and quantitatively. The purpose of this study is to evaluate and compare six scatter correction methods based on setting the energy windows in (99m)Tc spectrum. SIMIND Monte Carlo simulation is used to generate the projection images from a cold-sphere hot-background phantom. For evaluation of different scatter correction methods, three assessment criteria including image contrast, signal-to-noise ratio (SNR) and relative noise of the background (RNB) are considered. Except for the dual-photopeak window (DPW) method, the image contrast of the five cold spheres is improved in the range of 2.7-26%. Among methods considered, two methods show a nonuniform correction performance. The RNB for all of the scatter correction methods is ranged from minimum 0.03 for DPW method to maximum 0.0727 for the three energy window (TEW) method using trapezoidal approximation. The TEW method using triangular approximation because of ease of implementation, good improvement of the image contrast and the SNR for the five cold spheres, and the low noise level is proposed as most appropriate correction method. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3958999/ /pubmed/24672154 http://dx.doi.org/10.4103/0971-6203.121197 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Asl, Mahsa Noori Sadremomtaz, Alireza Bitarafan-Rajabi, Ahmad Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation |
title | Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation |
title_full | Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation |
title_fullStr | Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation |
title_full_unstemmed | Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation |
title_short | Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation |
title_sort | evaluation of six scatter correction methods based on spectral analysis in (99m)tc spect imaging using simind monte carlo simulation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958999/ https://www.ncbi.nlm.nih.gov/pubmed/24672154 http://dx.doi.org/10.4103/0971-6203.121197 |
work_keys_str_mv | AT aslmahsanoori evaluationofsixscattercorrectionmethodsbasedonspectralanalysisin99mtcspectimagingusingsimindmontecarlosimulation AT sadremomtazalireza evaluationofsixscattercorrectionmethodsbasedonspectralanalysisin99mtcspectimagingusingsimindmontecarlosimulation AT bitarafanrajabiahmad evaluationofsixscattercorrectionmethodsbasedonspectralanalysisin99mtcspectimagingusingsimindmontecarlosimulation |