Cargando…

Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation

Compton-scattered photons included within the photopeak pulse-height window result in the degradation of SPECT images both qualitatively and quantitatively. The purpose of this study is to evaluate and compare six scatter correction methods based on setting the energy windows in (99m)Tc spectrum. SI...

Descripción completa

Detalles Bibliográficos
Autores principales: Asl, Mahsa Noori, Sadremomtaz, Alireza, Bitarafan-Rajabi, Ahmad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958999/
https://www.ncbi.nlm.nih.gov/pubmed/24672154
http://dx.doi.org/10.4103/0971-6203.121197
_version_ 1782307980776046592
author Asl, Mahsa Noori
Sadremomtaz, Alireza
Bitarafan-Rajabi, Ahmad
author_facet Asl, Mahsa Noori
Sadremomtaz, Alireza
Bitarafan-Rajabi, Ahmad
author_sort Asl, Mahsa Noori
collection PubMed
description Compton-scattered photons included within the photopeak pulse-height window result in the degradation of SPECT images both qualitatively and quantitatively. The purpose of this study is to evaluate and compare six scatter correction methods based on setting the energy windows in (99m)Tc spectrum. SIMIND Monte Carlo simulation is used to generate the projection images from a cold-sphere hot-background phantom. For evaluation of different scatter correction methods, three assessment criteria including image contrast, signal-to-noise ratio (SNR) and relative noise of the background (RNB) are considered. Except for the dual-photopeak window (DPW) method, the image contrast of the five cold spheres is improved in the range of 2.7-26%. Among methods considered, two methods show a nonuniform correction performance. The RNB for all of the scatter correction methods is ranged from minimum 0.03 for DPW method to maximum 0.0727 for the three energy window (TEW) method using trapezoidal approximation. The TEW method using triangular approximation because of ease of implementation, good improvement of the image contrast and the SNR for the five cold spheres, and the low noise level is proposed as most appropriate correction method.
format Online
Article
Text
id pubmed-3958999
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-39589992014-03-26 Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation Asl, Mahsa Noori Sadremomtaz, Alireza Bitarafan-Rajabi, Ahmad J Med Phys Original Article Compton-scattered photons included within the photopeak pulse-height window result in the degradation of SPECT images both qualitatively and quantitatively. The purpose of this study is to evaluate and compare six scatter correction methods based on setting the energy windows in (99m)Tc spectrum. SIMIND Monte Carlo simulation is used to generate the projection images from a cold-sphere hot-background phantom. For evaluation of different scatter correction methods, three assessment criteria including image contrast, signal-to-noise ratio (SNR) and relative noise of the background (RNB) are considered. Except for the dual-photopeak window (DPW) method, the image contrast of the five cold spheres is improved in the range of 2.7-26%. Among methods considered, two methods show a nonuniform correction performance. The RNB for all of the scatter correction methods is ranged from minimum 0.03 for DPW method to maximum 0.0727 for the three energy window (TEW) method using trapezoidal approximation. The TEW method using triangular approximation because of ease of implementation, good improvement of the image contrast and the SNR for the five cold spheres, and the low noise level is proposed as most appropriate correction method. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3958999/ /pubmed/24672154 http://dx.doi.org/10.4103/0971-6203.121197 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Asl, Mahsa Noori
Sadremomtaz, Alireza
Bitarafan-Rajabi, Ahmad
Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
title Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
title_full Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
title_fullStr Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
title_full_unstemmed Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
title_short Evaluation of six scatter correction methods based on spectral analysis in (99m)Tc SPECT imaging using SIMIND Monte Carlo simulation
title_sort evaluation of six scatter correction methods based on spectral analysis in (99m)tc spect imaging using simind monte carlo simulation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958999/
https://www.ncbi.nlm.nih.gov/pubmed/24672154
http://dx.doi.org/10.4103/0971-6203.121197
work_keys_str_mv AT aslmahsanoori evaluationofsixscattercorrectionmethodsbasedonspectralanalysisin99mtcspectimagingusingsimindmontecarlosimulation
AT sadremomtazalireza evaluationofsixscattercorrectionmethodsbasedonspectralanalysisin99mtcspectimagingusingsimindmontecarlosimulation
AT bitarafanrajabiahmad evaluationofsixscattercorrectionmethodsbasedonspectralanalysisin99mtcspectimagingusingsimindmontecarlosimulation