Cargando…

Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial

PURPOSE: To perform a comparative evaluation of the efficacy and acceptability of Rose-K and Soper contact lenses in Keratoconus. SETTING: Dr. Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. MATERIALS AND METHODS: A randomized comparative clinical...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Raghav, Sinha, Rajesh, Singh, Pooja, Sharma, Namrata, Tandon, Radhika, Titiyal, Jeewan S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3959042/
https://www.ncbi.nlm.nih.gov/pubmed/24669146
http://dx.doi.org/10.4103/0974-9233.124095
_version_ 1782307990471180288
author Gupta, Raghav
Sinha, Rajesh
Singh, Pooja
Sharma, Namrata
Tandon, Radhika
Titiyal, Jeewan S.
author_facet Gupta, Raghav
Sinha, Rajesh
Singh, Pooja
Sharma, Namrata
Tandon, Radhika
Titiyal, Jeewan S.
author_sort Gupta, Raghav
collection PubMed
description PURPOSE: To perform a comparative evaluation of the efficacy and acceptability of Rose-K and Soper contact lenses in Keratoconus. SETTING: Dr. Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. MATERIALS AND METHODS: A randomized comparative clinical trial was performed in keratoconic eyes fitted with Rose-K (Rose-K group) and Soper (Soper group) contact lenses. Patients data were evaluated for best spectacle corrected visual acuity, best contact lens corrected visual acuity (BCLCVA), corneal topography, glare acuity, contrast sensitivity, tear function tests and specular microscopy. Patients were also asked to complete a self-reported comfort questionnaire at each visit. RESULTS: Sixty eyes were randomized to the Rose-K and Soper groups. The two groups were comparable in all the baseline parameters. There was a statistically significant improvement in BCLCVA in both groups at 3 months (P < 0.01, both groups). The difference between in BCLCVA in both groups was not statistically significant. In both groups, there was a significant improvement in the comfort score at 3 months compared to baseline (P < 0.05, both group). The Rose-K group had statistically significantly better scores at 1 and 3 months compared with the Soper group (P = 0.006 and P < 0.001 respectively). Both groups were associated with a significant (P < 0.01), but comparable improvement in glare acuity at 3 months. There was a significant improvement in contrast sensitivity at 3 months in both groups (P < 0.01); the Rose-K group was significantly better than the Soper group at 1 and 3 months (P = 0.001 and 0.002 respectively). The mean number of trial lenses required for fitting Rose-K lens (2.00 ± 0.59) was significantly lower than the Soper lens (3.43 ± 0.82; P < 0.001). CONCLUSION: Both the contact lens designs provide an equal improvement in visual acuity in patients with Keratoconus. However, Rose-K contact lens provides greater comfort, better quality of vision and requires less chair time compared with the Soper lens and hence may possibly have a greater acceptability.
format Online
Article
Text
id pubmed-3959042
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-39590422014-03-25 Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial Gupta, Raghav Sinha, Rajesh Singh, Pooja Sharma, Namrata Tandon, Radhika Titiyal, Jeewan S. Middle East Afr J Ophthalmol Original Article PURPOSE: To perform a comparative evaluation of the efficacy and acceptability of Rose-K and Soper contact lenses in Keratoconus. SETTING: Dr. Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. MATERIALS AND METHODS: A randomized comparative clinical trial was performed in keratoconic eyes fitted with Rose-K (Rose-K group) and Soper (Soper group) contact lenses. Patients data were evaluated for best spectacle corrected visual acuity, best contact lens corrected visual acuity (BCLCVA), corneal topography, glare acuity, contrast sensitivity, tear function tests and specular microscopy. Patients were also asked to complete a self-reported comfort questionnaire at each visit. RESULTS: Sixty eyes were randomized to the Rose-K and Soper groups. The two groups were comparable in all the baseline parameters. There was a statistically significant improvement in BCLCVA in both groups at 3 months (P < 0.01, both groups). The difference between in BCLCVA in both groups was not statistically significant. In both groups, there was a significant improvement in the comfort score at 3 months compared to baseline (P < 0.05, both group). The Rose-K group had statistically significantly better scores at 1 and 3 months compared with the Soper group (P = 0.006 and P < 0.001 respectively). Both groups were associated with a significant (P < 0.01), but comparable improvement in glare acuity at 3 months. There was a significant improvement in contrast sensitivity at 3 months in both groups (P < 0.01); the Rose-K group was significantly better than the Soper group at 1 and 3 months (P = 0.001 and 0.002 respectively). The mean number of trial lenses required for fitting Rose-K lens (2.00 ± 0.59) was significantly lower than the Soper lens (3.43 ± 0.82; P < 0.001). CONCLUSION: Both the contact lens designs provide an equal improvement in visual acuity in patients with Keratoconus. However, Rose-K contact lens provides greater comfort, better quality of vision and requires less chair time compared with the Soper lens and hence may possibly have a greater acceptability. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC3959042/ /pubmed/24669146 http://dx.doi.org/10.4103/0974-9233.124095 Text en Copyright: © Middle East African Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Gupta, Raghav
Sinha, Rajesh
Singh, Pooja
Sharma, Namrata
Tandon, Radhika
Titiyal, Jeewan S.
Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial
title Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial
title_full Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial
title_fullStr Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial
title_full_unstemmed Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial
title_short Rose-K versus Soper Contact Lens in Keratoconus: A Randomized Comparative Trial
title_sort rose-k versus soper contact lens in keratoconus: a randomized comparative trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3959042/
https://www.ncbi.nlm.nih.gov/pubmed/24669146
http://dx.doi.org/10.4103/0974-9233.124095
work_keys_str_mv AT guptaraghav rosekversussopercontactlensinkeratoconusarandomizedcomparativetrial
AT sinharajesh rosekversussopercontactlensinkeratoconusarandomizedcomparativetrial
AT singhpooja rosekversussopercontactlensinkeratoconusarandomizedcomparativetrial
AT sharmanamrata rosekversussopercontactlensinkeratoconusarandomizedcomparativetrial
AT tandonradhika rosekversussopercontactlensinkeratoconusarandomizedcomparativetrial
AT titiyaljeewans rosekversussopercontactlensinkeratoconusarandomizedcomparativetrial