Cargando…

Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension

PURPOSE: The 6 minutes walk test (6MWT) is often shown to be the best predictor of mortality in pulmonary hypertension (PH) probably because it challenges the failing heart to deliver adequate cardiac output. We hypothesised that the 6MWT elicits maximal cardiac output as measured during a maximal c...

Descripción completa

Detalles Bibliográficos
Autores principales: Deboeck, Gaël, Taboada, Dolores, Hagan, Guy, Treacy, Carmen, Page, Kathy, Sheares, Karen, Naeije, Robert, Pepke-Zaba, Joanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3960234/
https://www.ncbi.nlm.nih.gov/pubmed/24647561
http://dx.doi.org/10.1371/journal.pone.0092324
_version_ 1782308144844636160
author Deboeck, Gaël
Taboada, Dolores
Hagan, Guy
Treacy, Carmen
Page, Kathy
Sheares, Karen
Naeije, Robert
Pepke-Zaba, Joanna
author_facet Deboeck, Gaël
Taboada, Dolores
Hagan, Guy
Treacy, Carmen
Page, Kathy
Sheares, Karen
Naeije, Robert
Pepke-Zaba, Joanna
author_sort Deboeck, Gaël
collection PubMed
description PURPOSE: The 6 minutes walk test (6MWT) is often shown to be the best predictor of mortality in pulmonary hypertension (PH) probably because it challenges the failing heart to deliver adequate cardiac output. We hypothesised that the 6MWT elicits maximal cardiac output as measured during a maximal cardiopulmonary exercise testing (CPET). METHODS: 18 patients with chronic thromboembolic pulmonary hypertension (n = 12) or pulmonary arterial hypertension (n = 6) and 10 healthy subjects performed a 6MWT and CPET with measurements of cardiac output (non invasive rebreathing device) before and directly after exercise. Heart rate was measured during 6MWT with a cardiofrequence meter. RESULTS: Cardiac output and heart rate measured at the end of the 6MWT were linearly related to 6MW distance (mean±SD: 490±87 m). Patients with a high NT-pro-BNP achieve a maximum cardiac output during the 6MWT, while in normal subjects and in patients with a low-normal NT-proBNP, cardiac output at the end of a 6MWT was lower than achieved at maximum exercise during a CPET. In both cases, heart rate is the major determinant of exercise-induced increase in cardiac output. However, stroke volume increased during CPET in healthy subjects, not in PH patients. CONCLUSION: Maximal cardiac output is elicited by 6MWT in PH patients with failing right ventricle. Cardiac output increase is dependent on chronotropic response in patients with PH.
format Online
Article
Text
id pubmed-3960234
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-39602342014-03-24 Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension Deboeck, Gaël Taboada, Dolores Hagan, Guy Treacy, Carmen Page, Kathy Sheares, Karen Naeije, Robert Pepke-Zaba, Joanna PLoS One Research Article PURPOSE: The 6 minutes walk test (6MWT) is often shown to be the best predictor of mortality in pulmonary hypertension (PH) probably because it challenges the failing heart to deliver adequate cardiac output. We hypothesised that the 6MWT elicits maximal cardiac output as measured during a maximal cardiopulmonary exercise testing (CPET). METHODS: 18 patients with chronic thromboembolic pulmonary hypertension (n = 12) or pulmonary arterial hypertension (n = 6) and 10 healthy subjects performed a 6MWT and CPET with measurements of cardiac output (non invasive rebreathing device) before and directly after exercise. Heart rate was measured during 6MWT with a cardiofrequence meter. RESULTS: Cardiac output and heart rate measured at the end of the 6MWT were linearly related to 6MW distance (mean±SD: 490±87 m). Patients with a high NT-pro-BNP achieve a maximum cardiac output during the 6MWT, while in normal subjects and in patients with a low-normal NT-proBNP, cardiac output at the end of a 6MWT was lower than achieved at maximum exercise during a CPET. In both cases, heart rate is the major determinant of exercise-induced increase in cardiac output. However, stroke volume increased during CPET in healthy subjects, not in PH patients. CONCLUSION: Maximal cardiac output is elicited by 6MWT in PH patients with failing right ventricle. Cardiac output increase is dependent on chronotropic response in patients with PH. Public Library of Science 2014-03-19 /pmc/articles/PMC3960234/ /pubmed/24647561 http://dx.doi.org/10.1371/journal.pone.0092324 Text en © 2014 Deboeck et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Deboeck, Gaël
Taboada, Dolores
Hagan, Guy
Treacy, Carmen
Page, Kathy
Sheares, Karen
Naeije, Robert
Pepke-Zaba, Joanna
Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension
title Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension
title_full Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension
title_fullStr Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension
title_full_unstemmed Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension
title_short Maximal Cardiac Output Determines 6 Minutes Walking Distance in Pulmonary Hypertension
title_sort maximal cardiac output determines 6 minutes walking distance in pulmonary hypertension
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3960234/
https://www.ncbi.nlm.nih.gov/pubmed/24647561
http://dx.doi.org/10.1371/journal.pone.0092324
work_keys_str_mv AT deboeckgael maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT taboadadolores maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT haganguy maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT treacycarmen maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT pagekathy maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT sheareskaren maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT naeijerobert maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension
AT pepkezabajoanna maximalcardiacoutputdetermines6minuteswalkingdistanceinpulmonaryhypertension