Cargando…
A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft
BACKGROUND: Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Plastic and Reconstructive Surgeons
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3961609/ https://www.ncbi.nlm.nih.gov/pubmed/24665420 http://dx.doi.org/10.5999/aps.2014.41.2.126 |
_version_ | 1782308322886549504 |
---|---|
author | Lim, Hyoseob Han, Dae Hee Lee, Il Jae Park, Myong Chul |
author_facet | Lim, Hyoseob Han, Dae Hee Lee, Il Jae Park, Myong Chul |
author_sort | Lim, Hyoseob |
collection | PubMed |
description | BACKGROUND: Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. METHODS: We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. RESULTS: Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. CONCLUSIONS: A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft. |
format | Online Article Text |
id | pubmed-3961609 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society of Plastic and Reconstructive Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-39616092014-03-24 A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft Lim, Hyoseob Han, Dae Hee Lee, Il Jae Park, Myong Chul Arch Plast Surg Original Article BACKGROUND: Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. METHODS: We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. RESULTS: Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. CONCLUSIONS: A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft. The Korean Society of Plastic and Reconstructive Surgeons 2014-03 2014-03-12 /pmc/articles/PMC3961609/ /pubmed/24665420 http://dx.doi.org/10.5999/aps.2014.41.2.126 Text en Copyright © 2014 The Korean Society of Plastic and Reconstructive Surgeons http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lim, Hyoseob Han, Dae Hee Lee, Il Jae Park, Myong Chul A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft |
title | A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft |
title_full | A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft |
title_fullStr | A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft |
title_full_unstemmed | A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft |
title_short | A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft |
title_sort | simple strategy in avulsion flap injury: prediction of flap viability using wood's lamp illumination and resurfacing with a full-thickness skin graft |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3961609/ https://www.ncbi.nlm.nih.gov/pubmed/24665420 http://dx.doi.org/10.5999/aps.2014.41.2.126 |
work_keys_str_mv | AT limhyoseob asimplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT handaehee asimplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT leeiljae asimplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT parkmyongchul asimplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT limhyoseob simplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT handaehee simplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT leeiljae simplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft AT parkmyongchul simplestrategyinavulsionflapinjurypredictionofflapviabilityusingwoodslampilluminationandresurfacingwithafullthicknessskingraft |