Cargando…
Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
BACKGROUND: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-fr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964437/ https://www.ncbi.nlm.nih.gov/pubmed/24719719 http://dx.doi.org/10.5812/ircmj.9628 |
_version_ | 1782308644091592704 |
---|---|
author | Mehrparvar, Amir Houshang Mirmohammadi, Seyyed Jalil Davari, Mohammad Hossein Mostaghaci, Mehrdad Mollasadeghi, Abolfazl Bahaloo, Maryam Hashemi, Seyyed Hesam |
author_facet | Mehrparvar, Amir Houshang Mirmohammadi, Seyyed Jalil Davari, Mohammad Hossein Mostaghaci, Mehrdad Mollasadeghi, Abolfazl Bahaloo, Maryam Hashemi, Seyyed Hesam |
author_sort | Mehrparvar, Amir Houshang |
collection | PubMed |
description | BACKGROUND: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). MATERIAL AND METHODS: This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated measures analysis. Study samples were workers from tile and ceramic industry. RESULTS: We found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants. Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry. CONCLUSIONS: Extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic. |
format | Online Article Text |
id | pubmed-3964437 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-39644372014-04-09 Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL Mehrparvar, Amir Houshang Mirmohammadi, Seyyed Jalil Davari, Mohammad Hossein Mostaghaci, Mehrdad Mollasadeghi, Abolfazl Bahaloo, Maryam Hashemi, Seyyed Hesam Iran Red Crescent Med J Research Article BACKGROUND: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). MATERIAL AND METHODS: This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated measures analysis. Study samples were workers from tile and ceramic industry. RESULTS: We found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants. Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry. CONCLUSIONS: Extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic. Kowsar 2014-01-05 2014-01 /pmc/articles/PMC3964437/ /pubmed/24719719 http://dx.doi.org/10.5812/ircmj.9628 Text en Copyright © 2014, Iranian Red Crescent Medical Journal http://creativecommons.org/licenses/by/3/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mehrparvar, Amir Houshang Mirmohammadi, Seyyed Jalil Davari, Mohammad Hossein Mostaghaci, Mehrdad Mollasadeghi, Abolfazl Bahaloo, Maryam Hashemi, Seyyed Hesam Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL |
title | Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL |
title_full | Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL |
title_fullStr | Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL |
title_full_unstemmed | Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL |
title_short | Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL |
title_sort | conventional audiometry, extended high-frequency audiometry, and dpoae for early diagnosis of nihl |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964437/ https://www.ncbi.nlm.nih.gov/pubmed/24719719 http://dx.doi.org/10.5812/ircmj.9628 |
work_keys_str_mv | AT mehrparvaramirhoushang conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl AT mirmohammadiseyyedjalil conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl AT davarimohammadhossein conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl AT mostaghacimehrdad conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl AT mollasadeghiabolfazl conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl AT bahaloomaryam conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl AT hashemiseyyedhesam conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl |