Cargando…

Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL

BACKGROUND: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehrparvar, Amir Houshang, Mirmohammadi, Seyyed Jalil, Davari, Mohammad Hossein, Mostaghaci, Mehrdad, Mollasadeghi, Abolfazl, Bahaloo, Maryam, Hashemi, Seyyed Hesam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964437/
https://www.ncbi.nlm.nih.gov/pubmed/24719719
http://dx.doi.org/10.5812/ircmj.9628
_version_ 1782308644091592704
author Mehrparvar, Amir Houshang
Mirmohammadi, Seyyed Jalil
Davari, Mohammad Hossein
Mostaghaci, Mehrdad
Mollasadeghi, Abolfazl
Bahaloo, Maryam
Hashemi, Seyyed Hesam
author_facet Mehrparvar, Amir Houshang
Mirmohammadi, Seyyed Jalil
Davari, Mohammad Hossein
Mostaghaci, Mehrdad
Mollasadeghi, Abolfazl
Bahaloo, Maryam
Hashemi, Seyyed Hesam
author_sort Mehrparvar, Amir Houshang
collection PubMed
description BACKGROUND: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). MATERIAL AND METHODS: This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated measures analysis. Study samples were workers from tile and ceramic industry. RESULTS: We found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants. Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry. CONCLUSIONS: Extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic.
format Online
Article
Text
id pubmed-3964437
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-39644372014-04-09 Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL Mehrparvar, Amir Houshang Mirmohammadi, Seyyed Jalil Davari, Mohammad Hossein Mostaghaci, Mehrdad Mollasadeghi, Abolfazl Bahaloo, Maryam Hashemi, Seyyed Hesam Iran Red Crescent Med J Research Article BACKGROUND: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). MATERIAL AND METHODS: This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated measures analysis. Study samples were workers from tile and ceramic industry. RESULTS: We found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants. Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry. CONCLUSIONS: Extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic. Kowsar 2014-01-05 2014-01 /pmc/articles/PMC3964437/ /pubmed/24719719 http://dx.doi.org/10.5812/ircmj.9628 Text en Copyright © 2014, Iranian Red Crescent Medical Journal http://creativecommons.org/licenses/by/3/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mehrparvar, Amir Houshang
Mirmohammadi, Seyyed Jalil
Davari, Mohammad Hossein
Mostaghaci, Mehrdad
Mollasadeghi, Abolfazl
Bahaloo, Maryam
Hashemi, Seyyed Hesam
Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
title Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
title_full Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
title_fullStr Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
title_full_unstemmed Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
title_short Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
title_sort conventional audiometry, extended high-frequency audiometry, and dpoae for early diagnosis of nihl
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964437/
https://www.ncbi.nlm.nih.gov/pubmed/24719719
http://dx.doi.org/10.5812/ircmj.9628
work_keys_str_mv AT mehrparvaramirhoushang conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl
AT mirmohammadiseyyedjalil conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl
AT davarimohammadhossein conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl
AT mostaghacimehrdad conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl
AT mollasadeghiabolfazl conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl
AT bahaloomaryam conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl
AT hashemiseyyedhesam conventionalaudiometryextendedhighfrequencyaudiometryanddpoaeforearlydiagnosisofnihl