Cargando…

Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM

Biological membranes contain ion channels, which are nanoscale pores allowing controlled ionic transport and mediating key biological functions underlying normal/abnormal living. Synthetic membranes with defined pores are being developed to control various processes, including filtration of pollutan...

Descripción completa

Detalles Bibliográficos
Autores principales: Meckes, Brian, Arce, Fernando Teran, Connelly, Laura S., Lal, Ratnesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964513/
https://www.ncbi.nlm.nih.gov/pubmed/24663394
http://dx.doi.org/10.1038/srep04454
_version_ 1782308658036604928
author Meckes, Brian
Arce, Fernando Teran
Connelly, Laura S.
Lal, Ratnesh
author_facet Meckes, Brian
Arce, Fernando Teran
Connelly, Laura S.
Lal, Ratnesh
author_sort Meckes, Brian
collection PubMed
description Biological membranes contain ion channels, which are nanoscale pores allowing controlled ionic transport and mediating key biological functions underlying normal/abnormal living. Synthetic membranes with defined pores are being developed to control various processes, including filtration of pollutants, charge transport for energy storage, and separation of fluids and molecules. Although ionic transport (currents) can be measured with single channel resolution, imaging their structure and ionic currents simultaneously is difficult. Atomic force microscopy enables high resolution imaging of nanoscale structures and can be modified to measure ionic currents simultaneously. Moreover, the ionic currents can also be used to image structures. A simple method for fabricating conducting AFM cantilevers to image pore structures at high resolution is reported. Tungsten microwires with nanoscale tips are insulated except at the apex. This allows simultaneous imaging via cantilever deflections in normal AFM force feedback mode as well as measuring localized ionic currents. These novel probes measure ionic currents as small as picoampere while providing nanoscale spatial resolution surface topography and is suitable for measuring ionic currents and conductance of biological ion channels.
format Online
Article
Text
id pubmed-3964513
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-39645132014-03-25 Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM Meckes, Brian Arce, Fernando Teran Connelly, Laura S. Lal, Ratnesh Sci Rep Article Biological membranes contain ion channels, which are nanoscale pores allowing controlled ionic transport and mediating key biological functions underlying normal/abnormal living. Synthetic membranes with defined pores are being developed to control various processes, including filtration of pollutants, charge transport for energy storage, and separation of fluids and molecules. Although ionic transport (currents) can be measured with single channel resolution, imaging their structure and ionic currents simultaneously is difficult. Atomic force microscopy enables high resolution imaging of nanoscale structures and can be modified to measure ionic currents simultaneously. Moreover, the ionic currents can also be used to image structures. A simple method for fabricating conducting AFM cantilevers to image pore structures at high resolution is reported. Tungsten microwires with nanoscale tips are insulated except at the apex. This allows simultaneous imaging via cantilever deflections in normal AFM force feedback mode as well as measuring localized ionic currents. These novel probes measure ionic currents as small as picoampere while providing nanoscale spatial resolution surface topography and is suitable for measuring ionic currents and conductance of biological ion channels. Nature Publishing Group 2014-03-25 /pmc/articles/PMC3964513/ /pubmed/24663394 http://dx.doi.org/10.1038/srep04454 Text en Copyright © 2014, Macmillan Publishers Limited. All rights reserved http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported license. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Article
Meckes, Brian
Arce, Fernando Teran
Connelly, Laura S.
Lal, Ratnesh
Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
title Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
title_full Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
title_fullStr Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
title_full_unstemmed Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
title_short Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
title_sort insulated conducting cantilevered nanotips and two-chamber recording system for high resolution ion sensing afm
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964513/
https://www.ncbi.nlm.nih.gov/pubmed/24663394
http://dx.doi.org/10.1038/srep04454
work_keys_str_mv AT meckesbrian insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm
AT arcefernandoteran insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm
AT connellylauras insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm
AT lalratnesh insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm