Cargando…
Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM
Biological membranes contain ion channels, which are nanoscale pores allowing controlled ionic transport and mediating key biological functions underlying normal/abnormal living. Synthetic membranes with defined pores are being developed to control various processes, including filtration of pollutan...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964513/ https://www.ncbi.nlm.nih.gov/pubmed/24663394 http://dx.doi.org/10.1038/srep04454 |
_version_ | 1782308658036604928 |
---|---|
author | Meckes, Brian Arce, Fernando Teran Connelly, Laura S. Lal, Ratnesh |
author_facet | Meckes, Brian Arce, Fernando Teran Connelly, Laura S. Lal, Ratnesh |
author_sort | Meckes, Brian |
collection | PubMed |
description | Biological membranes contain ion channels, which are nanoscale pores allowing controlled ionic transport and mediating key biological functions underlying normal/abnormal living. Synthetic membranes with defined pores are being developed to control various processes, including filtration of pollutants, charge transport for energy storage, and separation of fluids and molecules. Although ionic transport (currents) can be measured with single channel resolution, imaging their structure and ionic currents simultaneously is difficult. Atomic force microscopy enables high resolution imaging of nanoscale structures and can be modified to measure ionic currents simultaneously. Moreover, the ionic currents can also be used to image structures. A simple method for fabricating conducting AFM cantilevers to image pore structures at high resolution is reported. Tungsten microwires with nanoscale tips are insulated except at the apex. This allows simultaneous imaging via cantilever deflections in normal AFM force feedback mode as well as measuring localized ionic currents. These novel probes measure ionic currents as small as picoampere while providing nanoscale spatial resolution surface topography and is suitable for measuring ionic currents and conductance of biological ion channels. |
format | Online Article Text |
id | pubmed-3964513 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-39645132014-03-25 Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM Meckes, Brian Arce, Fernando Teran Connelly, Laura S. Lal, Ratnesh Sci Rep Article Biological membranes contain ion channels, which are nanoscale pores allowing controlled ionic transport and mediating key biological functions underlying normal/abnormal living. Synthetic membranes with defined pores are being developed to control various processes, including filtration of pollutants, charge transport for energy storage, and separation of fluids and molecules. Although ionic transport (currents) can be measured with single channel resolution, imaging their structure and ionic currents simultaneously is difficult. Atomic force microscopy enables high resolution imaging of nanoscale structures and can be modified to measure ionic currents simultaneously. Moreover, the ionic currents can also be used to image structures. A simple method for fabricating conducting AFM cantilevers to image pore structures at high resolution is reported. Tungsten microwires with nanoscale tips are insulated except at the apex. This allows simultaneous imaging via cantilever deflections in normal AFM force feedback mode as well as measuring localized ionic currents. These novel probes measure ionic currents as small as picoampere while providing nanoscale spatial resolution surface topography and is suitable for measuring ionic currents and conductance of biological ion channels. Nature Publishing Group 2014-03-25 /pmc/articles/PMC3964513/ /pubmed/24663394 http://dx.doi.org/10.1038/srep04454 Text en Copyright © 2014, Macmillan Publishers Limited. All rights reserved http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported license. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Article Meckes, Brian Arce, Fernando Teran Connelly, Laura S. Lal, Ratnesh Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM |
title | Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM |
title_full | Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM |
title_fullStr | Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM |
title_full_unstemmed | Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM |
title_short | Insulated Conducting Cantilevered Nanotips and Two-Chamber Recording System for High Resolution Ion Sensing AFM |
title_sort | insulated conducting cantilevered nanotips and two-chamber recording system for high resolution ion sensing afm |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964513/ https://www.ncbi.nlm.nih.gov/pubmed/24663394 http://dx.doi.org/10.1038/srep04454 |
work_keys_str_mv | AT meckesbrian insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm AT arcefernandoteran insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm AT connellylauras insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm AT lalratnesh insulatedconductingcantileverednanotipsandtwochamberrecordingsystemforhighresolutionionsensingafm |