Cargando…

Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry

[Image: see text] Isotopic labeling studies of primary metabolism frequently utilize GC/MS to quantify (13)C in protein-hydrolyzed amino acids. During processing some amino acids are degraded, which reduces the size of the measurement set. The advent of high-resolution mass spectrometers provides a...

Descripción completa

Detalles Bibliográficos
Autores principales: Allen, Doug K., Goldford, Joshua, Gierse, James K., Mandy, Dominic, Diepenbrock, Christine, Libourel, Igor G. L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964731/
https://www.ncbi.nlm.nih.gov/pubmed/24387081
http://dx.doi.org/10.1021/ac403985w
_version_ 1782479231973851136
author Allen, Doug K.
Goldford, Joshua
Gierse, James K.
Mandy, Dominic
Diepenbrock, Christine
Libourel, Igor G. L.
author_facet Allen, Doug K.
Goldford, Joshua
Gierse, James K.
Mandy, Dominic
Diepenbrock, Christine
Libourel, Igor G. L.
author_sort Allen, Doug K.
collection PubMed
description [Image: see text] Isotopic labeling studies of primary metabolism frequently utilize GC/MS to quantify (13)C in protein-hydrolyzed amino acids. During processing some amino acids are degraded, which reduces the size of the measurement set. The advent of high-resolution mass spectrometers provides a tool to assess molecular masses of peptides with great precision and accuracy and computationally infer information about labeling in amino acids. Amino acids that are isotopically labeled during metabolism result in labeled peptides that contain spatial and temporal information that is associated with the biosynthetic origin of the protein. The quantification of isotopic labeling in peptides can therefore provide an assessment of amino acid metabolism that is specific to subcellular, cellular, or temporal conditions. A high-resolution orbital trap was used to quantify isotope labeling in peptides that were obtained from unlabeled and isotopically labeled soybean embryos and Escherichia coli cultures. Standard deviations were determined by estimating the multinomial variance associated with each element of the m/z distribution. Using the estimated variance, quantification of the m/z distribution across multiple scans was achieved by a nonlinear fitting approach. Observed m/z distributions of uniformly labeled E. coli peptides indicated no significant differences between observed and simulated m/z distributions. Alternatively, amino acid m/z distributions obtained from GC/MS were convolved to simulate peptide m/z distributions but resulted in distinct profiles due to the production of protein prior to isotopic labeling. The results indicate that peptide mass isotopologue measurements faithfully represent mass distributions, are suitable for quantification of isotope-labeling-based studies, and provide additional information over existing methods.
format Online
Article
Text
id pubmed-3964731
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-39647312014-03-25 Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry Allen, Doug K. Goldford, Joshua Gierse, James K. Mandy, Dominic Diepenbrock, Christine Libourel, Igor G. L. Anal Chem [Image: see text] Isotopic labeling studies of primary metabolism frequently utilize GC/MS to quantify (13)C in protein-hydrolyzed amino acids. During processing some amino acids are degraded, which reduces the size of the measurement set. The advent of high-resolution mass spectrometers provides a tool to assess molecular masses of peptides with great precision and accuracy and computationally infer information about labeling in amino acids. Amino acids that are isotopically labeled during metabolism result in labeled peptides that contain spatial and temporal information that is associated with the biosynthetic origin of the protein. The quantification of isotopic labeling in peptides can therefore provide an assessment of amino acid metabolism that is specific to subcellular, cellular, or temporal conditions. A high-resolution orbital trap was used to quantify isotope labeling in peptides that were obtained from unlabeled and isotopically labeled soybean embryos and Escherichia coli cultures. Standard deviations were determined by estimating the multinomial variance associated with each element of the m/z distribution. Using the estimated variance, quantification of the m/z distribution across multiple scans was achieved by a nonlinear fitting approach. Observed m/z distributions of uniformly labeled E. coli peptides indicated no significant differences between observed and simulated m/z distributions. Alternatively, amino acid m/z distributions obtained from GC/MS were convolved to simulate peptide m/z distributions but resulted in distinct profiles due to the production of protein prior to isotopic labeling. The results indicate that peptide mass isotopologue measurements faithfully represent mass distributions, are suitable for quantification of isotope-labeling-based studies, and provide additional information over existing methods. American Chemical Society 2014-01-03 2014-02-04 /pmc/articles/PMC3964731/ /pubmed/24387081 http://dx.doi.org/10.1021/ac403985w Text en Copyright © 2014 American Chemical Society Terms of Use (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html)
spellingShingle Allen, Doug K.
Goldford, Joshua
Gierse, James K.
Mandy, Dominic
Diepenbrock, Christine
Libourel, Igor G. L.
Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry
title Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry
title_full Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry
title_fullStr Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry
title_full_unstemmed Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry
title_short Quantification of Peptide m/z Distributions from (13)C-Labeled Cultures with High-Resolution Mass Spectrometry
title_sort quantification of peptide m/z distributions from (13)c-labeled cultures with high-resolution mass spectrometry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3964731/
https://www.ncbi.nlm.nih.gov/pubmed/24387081
http://dx.doi.org/10.1021/ac403985w
work_keys_str_mv AT allendougk quantificationofpeptidemzdistributionsfrom13clabeledcultureswithhighresolutionmassspectrometry
AT goldfordjoshua quantificationofpeptidemzdistributionsfrom13clabeledcultureswithhighresolutionmassspectrometry
AT giersejamesk quantificationofpeptidemzdistributionsfrom13clabeledcultureswithhighresolutionmassspectrometry
AT mandydominic quantificationofpeptidemzdistributionsfrom13clabeledcultureswithhighresolutionmassspectrometry
AT diepenbrockchristine quantificationofpeptidemzdistributionsfrom13clabeledcultureswithhighresolutionmassspectrometry
AT liboureligorgl quantificationofpeptidemzdistributionsfrom13clabeledcultureswithhighresolutionmassspectrometry