Cargando…

Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer

This paper presents comparative study of a new type of manometer called concentric tube bulb (C.T.B) manometer. Its performance of measuring differential height is studied against conventional U-shaped manometer. Pressure drops and mass flow rates are calculated by taking various systems comprising...

Descripción completa

Detalles Bibliográficos
Autores principales: Daood, Syed S., Ijaz, Aamir, Butt, Muhammad A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3965241/
https://www.ncbi.nlm.nih.gov/pubmed/28903264
_version_ 1782479314226249728
author Daood, Syed S.
Ijaz, Aamir
Butt, Muhammad A.
author_facet Daood, Syed S.
Ijaz, Aamir
Butt, Muhammad A.
author_sort Daood, Syed S.
collection PubMed
description This paper presents comparative study of a new type of manometer called concentric tube bulb (C.T.B) manometer. Its performance of measuring differential height is studied against conventional U-shaped manometer. Pressure drops and mass flow rates are calculated by taking various systems comprising of different flow measuring devices such as orifice and venturimeters using both U- shaped and C.T.B manometers. Comparison between the physically measured values of differential pressure drops and mass flow rates with the calculated values based on theoretical equations is also made. Experiments are carried out using mercury and CCl(4) in these manometers as sensing fluids. Water is used as flowing fluid for mass flow rate and pressure drop measurements, whereas in gauge pressure measurements air is used.
format Online
Article
Text
id pubmed-3965241
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-39652412014-03-25 Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer Daood, Syed S. Ijaz, Aamir Butt, Muhammad A. Sensors (Basel) Full Research Paper This paper presents comparative study of a new type of manometer called concentric tube bulb (C.T.B) manometer. Its performance of measuring differential height is studied against conventional U-shaped manometer. Pressure drops and mass flow rates are calculated by taking various systems comprising of different flow measuring devices such as orifice and venturimeters using both U- shaped and C.T.B manometers. Comparison between the physically measured values of differential pressure drops and mass flow rates with the calculated values based on theoretical equations is also made. Experiments are carried out using mercury and CCl(4) in these manometers as sensing fluids. Water is used as flowing fluid for mass flow rate and pressure drop measurements, whereas in gauge pressure measurements air is used. Molecular Diversity Preservation International (MDPI) 2007-11-20 /pmc/articles/PMC3965241/ /pubmed/28903264 Text en © 2007 by MDPI (http://www.mdpi.org). Reproduction is permitted for noncommercial purposes.
spellingShingle Full Research Paper
Daood, Syed S.
Ijaz, Aamir
Butt, Muhammad A.
Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
title Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
title_full Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
title_fullStr Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
title_full_unstemmed Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
title_short Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
title_sort study on a concentric tube bulb manometer and its performance compared to u-shaped manometer
topic Full Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3965241/
https://www.ncbi.nlm.nih.gov/pubmed/28903264
work_keys_str_mv AT daoodsyeds studyonaconcentrictubebulbmanometeranditsperformancecomparedtoushapedmanometer
AT ijazaamir studyonaconcentrictubebulbmanometeranditsperformancecomparedtoushapedmanometer
AT buttmuhammada studyonaconcentrictubebulbmanometeranditsperformancecomparedtoushapedmanometer