Cargando…
Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
This paper presents comparative study of a new type of manometer called concentric tube bulb (C.T.B) manometer. Its performance of measuring differential height is studied against conventional U-shaped manometer. Pressure drops and mass flow rates are calculated by taking various systems comprising...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3965241/ https://www.ncbi.nlm.nih.gov/pubmed/28903264 |
_version_ | 1782479314226249728 |
---|---|
author | Daood, Syed S. Ijaz, Aamir Butt, Muhammad A. |
author_facet | Daood, Syed S. Ijaz, Aamir Butt, Muhammad A. |
author_sort | Daood, Syed S. |
collection | PubMed |
description | This paper presents comparative study of a new type of manometer called concentric tube bulb (C.T.B) manometer. Its performance of measuring differential height is studied against conventional U-shaped manometer. Pressure drops and mass flow rates are calculated by taking various systems comprising of different flow measuring devices such as orifice and venturimeters using both U- shaped and C.T.B manometers. Comparison between the physically measured values of differential pressure drops and mass flow rates with the calculated values based on theoretical equations is also made. Experiments are carried out using mercury and CCl(4) in these manometers as sensing fluids. Water is used as flowing fluid for mass flow rate and pressure drop measurements, whereas in gauge pressure measurements air is used. |
format | Online Article Text |
id | pubmed-3965241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-39652412014-03-25 Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer Daood, Syed S. Ijaz, Aamir Butt, Muhammad A. Sensors (Basel) Full Research Paper This paper presents comparative study of a new type of manometer called concentric tube bulb (C.T.B) manometer. Its performance of measuring differential height is studied against conventional U-shaped manometer. Pressure drops and mass flow rates are calculated by taking various systems comprising of different flow measuring devices such as orifice and venturimeters using both U- shaped and C.T.B manometers. Comparison between the physically measured values of differential pressure drops and mass flow rates with the calculated values based on theoretical equations is also made. Experiments are carried out using mercury and CCl(4) in these manometers as sensing fluids. Water is used as flowing fluid for mass flow rate and pressure drop measurements, whereas in gauge pressure measurements air is used. Molecular Diversity Preservation International (MDPI) 2007-11-20 /pmc/articles/PMC3965241/ /pubmed/28903264 Text en © 2007 by MDPI (http://www.mdpi.org). Reproduction is permitted for noncommercial purposes. |
spellingShingle | Full Research Paper Daood, Syed S. Ijaz, Aamir Butt, Muhammad A. Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer |
title | Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer |
title_full | Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer |
title_fullStr | Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer |
title_full_unstemmed | Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer |
title_short | Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer |
title_sort | study on a concentric tube bulb manometer and its performance compared to u-shaped manometer |
topic | Full Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3965241/ https://www.ncbi.nlm.nih.gov/pubmed/28903264 |
work_keys_str_mv | AT daoodsyeds studyonaconcentrictubebulbmanometeranditsperformancecomparedtoushapedmanometer AT ijazaamir studyonaconcentrictubebulbmanometeranditsperformancecomparedtoushapedmanometer AT buttmuhammada studyonaconcentrictubebulbmanometeranditsperformancecomparedtoushapedmanometer |