Four-Wire Impedance Spectroscopy on Planar Zeolite/Chromium Oxide Based Hydrocarbon Gas Sensors
Impedometric zeolite hydrocarbon sensors with a chromium oxide intermediate layer show a very promising behavior with respect to sensitivity and selectivity. The underlying physico-chemical mechanism is under investigation at the moment. In order to verify that the effect occurs at the electrode and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3965245/ https://www.ncbi.nlm.nih.gov/pubmed/28903255 |
Sumario: | Impedometric zeolite hydrocarbon sensors with a chromium oxide intermediate layer show a very promising behavior with respect to sensitivity and selectivity. The underlying physico-chemical mechanism is under investigation at the moment. In order to verify that the effect occurs at the electrode and that zeolite bulk properties remain almost unaffected by hydrocarbons, a special planar setup was designed, which is very close to real sensor devices. It allows for conducting four-wire impedance spectroscopy as well as two-wire impedance spectroscopy. Using this setup, it could be clearly demonstrated that the sensing effect can be ascribed to an electrode impedance. Furthermore, by combining two- and four-wire impedance measurements at only one single frequency, the interference of the volume impedance can be suppressed and an easy signal evaluation is possible, without taking impedance data at different frequencies. |
---|