Cargando…

Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect

Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T(2)*-weighted echo-planar images. Three sets of image data shifted in th...

Descripción completa

Detalles Bibliográficos
Autores principales: Du, Yiping P., Chu, Renxin, Tregellas, Jason R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966417/
https://www.ncbi.nlm.nih.gov/pubmed/24734119
http://dx.doi.org/10.1155/2014/973972
_version_ 1782308911460646912
author Du, Yiping P.
Chu, Renxin
Tregellas, Jason R.
author_facet Du, Yiping P.
Chu, Renxin
Tregellas, Jason R.
author_sort Du, Yiping P.
collection PubMed
description Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T(2)*-weighted echo-planar images. Three sets of image data shifted in the x, y, and diagonal direction, respectively, are combined with the original 64 × 64 data to form the 128 × 128 voxel-shifted interpolated data. Results. A simulation of a synthetic fMRI dataset shows that the voxel-shifted interpolation (VSI) can increase the t-score up to 50% in single-voxel activations. An fMRI study (n = 7) demonstrates that 20.4% of the interpolated voxels have higher t-scores than their nearest neighboring voxels in the original maps. The average increase of the t-score in these interpolated voxels is 13.3%. Conclusion. VSI yields increased sensitivity in detecting voxel-size BOLD activations, improved spatial accuracy of activated regions, and improved detection of the peak BOLD signal of an activated region. VSI can potentially be used as an alternative to the high-resolution fMRI studies in which reduction in SNR and increase in imaging time become prohibitive.
format Online
Article
Text
id pubmed-3966417
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-39664172014-04-14 Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect Du, Yiping P. Chu, Renxin Tregellas, Jason R. Comput Math Methods Med Research Article Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T(2)*-weighted echo-planar images. Three sets of image data shifted in the x, y, and diagonal direction, respectively, are combined with the original 64 × 64 data to form the 128 × 128 voxel-shifted interpolated data. Results. A simulation of a synthetic fMRI dataset shows that the voxel-shifted interpolation (VSI) can increase the t-score up to 50% in single-voxel activations. An fMRI study (n = 7) demonstrates that 20.4% of the interpolated voxels have higher t-scores than their nearest neighboring voxels in the original maps. The average increase of the t-score in these interpolated voxels is 13.3%. Conclusion. VSI yields increased sensitivity in detecting voxel-size BOLD activations, improved spatial accuracy of activated regions, and improved detection of the peak BOLD signal of an activated region. VSI can potentially be used as an alternative to the high-resolution fMRI studies in which reduction in SNR and increase in imaging time become prohibitive. Hindawi Publishing Corporation 2014 2014-03-09 /pmc/articles/PMC3966417/ /pubmed/24734119 http://dx.doi.org/10.1155/2014/973972 Text en Copyright © 2014 Yiping P. Du et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Du, Yiping P.
Chu, Renxin
Tregellas, Jason R.
Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
title Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
title_full Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
title_fullStr Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
title_full_unstemmed Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
title_short Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
title_sort enhancing the detection of bold signal in fmri by reducing the partial volume effect
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966417/
https://www.ncbi.nlm.nih.gov/pubmed/24734119
http://dx.doi.org/10.1155/2014/973972
work_keys_str_mv AT duyipingp enhancingthedetectionofboldsignalinfmribyreducingthepartialvolumeeffect
AT churenxin enhancingthedetectionofboldsignalinfmribyreducingthepartialvolumeeffect
AT tregellasjasonr enhancingthedetectionofboldsignalinfmribyreducingthepartialvolumeeffect