Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect
Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T(2)*-weighted echo-planar images. Three sets of image data shifted in th...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966417/ https://www.ncbi.nlm.nih.gov/pubmed/24734119 http://dx.doi.org/10.1155/2014/973972 |
_version_ | 1782308911460646912 |
---|---|
author | Du, Yiping P. Chu, Renxin Tregellas, Jason R. |
author_facet | Du, Yiping P. Chu, Renxin Tregellas, Jason R. |
author_sort | Du, Yiping P. |
collection | PubMed |
description | Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T(2)*-weighted echo-planar images. Three sets of image data shifted in the x, y, and diagonal direction, respectively, are combined with the original 64 × 64 data to form the 128 × 128 voxel-shifted interpolated data. Results. A simulation of a synthetic fMRI dataset shows that the voxel-shifted interpolation (VSI) can increase the t-score up to 50% in single-voxel activations. An fMRI study (n = 7) demonstrates that 20.4% of the interpolated voxels have higher t-scores than their nearest neighboring voxels in the original maps. The average increase of the t-score in these interpolated voxels is 13.3%. Conclusion. VSI yields increased sensitivity in detecting voxel-size BOLD activations, improved spatial accuracy of activated regions, and improved detection of the peak BOLD signal of an activated region. VSI can potentially be used as an alternative to the high-resolution fMRI studies in which reduction in SNR and increase in imaging time become prohibitive. |
format | Online Article Text |
id | pubmed-3966417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-39664172014-04-14 Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect Du, Yiping P. Chu, Renxin Tregellas, Jason R. Comput Math Methods Med Research Article Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T(2)*-weighted echo-planar images. Three sets of image data shifted in the x, y, and diagonal direction, respectively, are combined with the original 64 × 64 data to form the 128 × 128 voxel-shifted interpolated data. Results. A simulation of a synthetic fMRI dataset shows that the voxel-shifted interpolation (VSI) can increase the t-score up to 50% in single-voxel activations. An fMRI study (n = 7) demonstrates that 20.4% of the interpolated voxels have higher t-scores than their nearest neighboring voxels in the original maps. The average increase of the t-score in these interpolated voxels is 13.3%. Conclusion. VSI yields increased sensitivity in detecting voxel-size BOLD activations, improved spatial accuracy of activated regions, and improved detection of the peak BOLD signal of an activated region. VSI can potentially be used as an alternative to the high-resolution fMRI studies in which reduction in SNR and increase in imaging time become prohibitive. Hindawi Publishing Corporation 2014 2014-03-09 /pmc/articles/PMC3966417/ /pubmed/24734119 http://dx.doi.org/10.1155/2014/973972 Text en Copyright © 2014 Yiping P. Du et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Du, Yiping P. Chu, Renxin Tregellas, Jason R. Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect |
title | Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect |
title_full | Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect |
title_fullStr | Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect |
title_full_unstemmed | Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect |
title_short | Enhancing the Detection of BOLD Signal in fMRI by Reducing the Partial Volume Effect |
title_sort | enhancing the detection of bold signal in fmri by reducing the partial volume effect |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966417/ https://www.ncbi.nlm.nih.gov/pubmed/24734119 http://dx.doi.org/10.1155/2014/973972 |
work_keys_str_mv | AT duyipingp enhancingthedetectionofboldsignalinfmribyreducingthepartialvolumeeffect AT churenxin enhancingthedetectionofboldsignalinfmribyreducingthepartialvolumeeffect AT tregellasjasonr enhancingthedetectionofboldsignalinfmribyreducingthepartialvolumeeffect |