Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure

INTRODUCTION: The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer va...

Descripción completa

Detalles Bibliográficos
Autores principales: Frumin, Erica, Schlang, Joelle, Wiechmann, Warren, Hata, Stacy, Rosen, Sasha, Anderson, Craig, Pare, Laura, Rosen, Mark, Fox, John Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Department of Emergency Medicine, University of California, Irvine School of Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966440/
https://www.ncbi.nlm.nih.gov/pubmed/24672615
http://dx.doi.org/10.5811/westjem.2013.9.16191
_version_ 1782308914649366528
author Frumin, Erica
Schlang, Joelle
Wiechmann, Warren
Hata, Stacy
Rosen, Sasha
Anderson, Craig
Pare, Laura
Rosen, Mark
Fox, John Christian
author_facet Frumin, Erica
Schlang, Joelle
Wiechmann, Warren
Hata, Stacy
Rosen, Sasha
Anderson, Craig
Pare, Laura
Rosen, Mark
Fox, John Christian
author_sort Frumin, Erica
collection PubMed
description INTRODUCTION: The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer variability or marginal performance with less experienced sonographers. The objective of our study is to assess the ability of bedside ultrasound measurement of ONSD to identify the presence of eICP when performed by a single experienced sonographer. We hypothesize that ONSD measurement is sensitive and specific for detecting eICP and can be correlated with values obtained by external ventricular device (EVD). METHODS: This was a prospective blinded observational study conducted in a neurocritical care unit of a level 1 trauma center. ONSD measurement was performed on a convenience sample of 27 adult patients who required placement of an invasive intracranial monitor as part of their clinical care. One certified sonographer/physician performed all ultrasounds within 24 hours of placement of EVD. The sonographer was blinded to the ICP recorded by invasive monitor at the time of the scan. A mean ONSD value of ≥5.2 mm was taken as positive. RESULTS: The sonographer performed 27 ocular ultrasounds on individual patients. Six (22%) of these patients had eICP (EVD measurement of >20 mmHg). Spearman rank correlation coefficient of ONSD and ICP was 0.408 (p=0.03), demonstrating a moderate positive correlation. A ROC curve was created to determine the optimal cut off value to distinguish an eICP greater than 20 mmHg. The area under the receiver operator characteristic curve was 0.8712 (95% confidence interval [CI]=0.67 to 0.96). ONSD ≥5.2 mm was a good predictor of eICP (>20 mmHg) with a sensitivity of 83.3% (95% CI=35.9% to 99.6%) and specificity of 100% (95% CI=84.6% to 100%). CONCLUSION: While the study suggests ONSD measurements performed by a single skilled operator may be both sensitive and specific for detecting eICP, confirmation in a much larger sample is needed. Ocular ultrasound may provide additional non-invasive means of assessing eICP.
format Online
Article
Text
id pubmed-3966440
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Department of Emergency Medicine, University of California, Irvine School of Medicine
record_format MEDLINE/PubMed
spelling pubmed-39664402014-03-26 Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure Frumin, Erica Schlang, Joelle Wiechmann, Warren Hata, Stacy Rosen, Sasha Anderson, Craig Pare, Laura Rosen, Mark Fox, John Christian West J Emerg Med Technology in Emergency Medicine Care INTRODUCTION: The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer variability or marginal performance with less experienced sonographers. The objective of our study is to assess the ability of bedside ultrasound measurement of ONSD to identify the presence of eICP when performed by a single experienced sonographer. We hypothesize that ONSD measurement is sensitive and specific for detecting eICP and can be correlated with values obtained by external ventricular device (EVD). METHODS: This was a prospective blinded observational study conducted in a neurocritical care unit of a level 1 trauma center. ONSD measurement was performed on a convenience sample of 27 adult patients who required placement of an invasive intracranial monitor as part of their clinical care. One certified sonographer/physician performed all ultrasounds within 24 hours of placement of EVD. The sonographer was blinded to the ICP recorded by invasive monitor at the time of the scan. A mean ONSD value of ≥5.2 mm was taken as positive. RESULTS: The sonographer performed 27 ocular ultrasounds on individual patients. Six (22%) of these patients had eICP (EVD measurement of >20 mmHg). Spearman rank correlation coefficient of ONSD and ICP was 0.408 (p=0.03), demonstrating a moderate positive correlation. A ROC curve was created to determine the optimal cut off value to distinguish an eICP greater than 20 mmHg. The area under the receiver operator characteristic curve was 0.8712 (95% confidence interval [CI]=0.67 to 0.96). ONSD ≥5.2 mm was a good predictor of eICP (>20 mmHg) with a sensitivity of 83.3% (95% CI=35.9% to 99.6%) and specificity of 100% (95% CI=84.6% to 100%). CONCLUSION: While the study suggests ONSD measurements performed by a single skilled operator may be both sensitive and specific for detecting eICP, confirmation in a much larger sample is needed. Ocular ultrasound may provide additional non-invasive means of assessing eICP. Department of Emergency Medicine, University of California, Irvine School of Medicine 2014-03 /pmc/articles/PMC3966440/ /pubmed/24672615 http://dx.doi.org/10.5811/westjem.2013.9.16191 Text en Copyright © 2014 the authors. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) License. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Technology in Emergency Medicine Care
Frumin, Erica
Schlang, Joelle
Wiechmann, Warren
Hata, Stacy
Rosen, Sasha
Anderson, Craig
Pare, Laura
Rosen, Mark
Fox, John Christian
Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
title Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
title_full Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
title_fullStr Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
title_full_unstemmed Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
title_short Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
title_sort prospective analysis of single operator sonographic optic nerve sheath diameter measurement for diagnosis of elevated intracranial pressure
topic Technology in Emergency Medicine Care
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966440/
https://www.ncbi.nlm.nih.gov/pubmed/24672615
http://dx.doi.org/10.5811/westjem.2013.9.16191
work_keys_str_mv AT fruminerica prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT schlangjoelle prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT wiechmannwarren prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT hatastacy prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT rosensasha prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT andersoncraig prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT parelaura prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT rosenmark prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure
AT foxjohnchristian prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure