Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
INTRODUCTION: The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer va...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Department of Emergency Medicine, University of California, Irvine School of Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966440/ https://www.ncbi.nlm.nih.gov/pubmed/24672615 http://dx.doi.org/10.5811/westjem.2013.9.16191 |
_version_ | 1782308914649366528 |
---|---|
author | Frumin, Erica Schlang, Joelle Wiechmann, Warren Hata, Stacy Rosen, Sasha Anderson, Craig Pare, Laura Rosen, Mark Fox, John Christian |
author_facet | Frumin, Erica Schlang, Joelle Wiechmann, Warren Hata, Stacy Rosen, Sasha Anderson, Craig Pare, Laura Rosen, Mark Fox, John Christian |
author_sort | Frumin, Erica |
collection | PubMed |
description | INTRODUCTION: The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer variability or marginal performance with less experienced sonographers. The objective of our study is to assess the ability of bedside ultrasound measurement of ONSD to identify the presence of eICP when performed by a single experienced sonographer. We hypothesize that ONSD measurement is sensitive and specific for detecting eICP and can be correlated with values obtained by external ventricular device (EVD). METHODS: This was a prospective blinded observational study conducted in a neurocritical care unit of a level 1 trauma center. ONSD measurement was performed on a convenience sample of 27 adult patients who required placement of an invasive intracranial monitor as part of their clinical care. One certified sonographer/physician performed all ultrasounds within 24 hours of placement of EVD. The sonographer was blinded to the ICP recorded by invasive monitor at the time of the scan. A mean ONSD value of ≥5.2 mm was taken as positive. RESULTS: The sonographer performed 27 ocular ultrasounds on individual patients. Six (22%) of these patients had eICP (EVD measurement of >20 mmHg). Spearman rank correlation coefficient of ONSD and ICP was 0.408 (p=0.03), demonstrating a moderate positive correlation. A ROC curve was created to determine the optimal cut off value to distinguish an eICP greater than 20 mmHg. The area under the receiver operator characteristic curve was 0.8712 (95% confidence interval [CI]=0.67 to 0.96). ONSD ≥5.2 mm was a good predictor of eICP (>20 mmHg) with a sensitivity of 83.3% (95% CI=35.9% to 99.6%) and specificity of 100% (95% CI=84.6% to 100%). CONCLUSION: While the study suggests ONSD measurements performed by a single skilled operator may be both sensitive and specific for detecting eICP, confirmation in a much larger sample is needed. Ocular ultrasound may provide additional non-invasive means of assessing eICP. |
format | Online Article Text |
id | pubmed-3966440 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Department of Emergency Medicine, University of California, Irvine School of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-39664402014-03-26 Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure Frumin, Erica Schlang, Joelle Wiechmann, Warren Hata, Stacy Rosen, Sasha Anderson, Craig Pare, Laura Rosen, Mark Fox, John Christian West J Emerg Med Technology in Emergency Medicine Care INTRODUCTION: The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer variability or marginal performance with less experienced sonographers. The objective of our study is to assess the ability of bedside ultrasound measurement of ONSD to identify the presence of eICP when performed by a single experienced sonographer. We hypothesize that ONSD measurement is sensitive and specific for detecting eICP and can be correlated with values obtained by external ventricular device (EVD). METHODS: This was a prospective blinded observational study conducted in a neurocritical care unit of a level 1 trauma center. ONSD measurement was performed on a convenience sample of 27 adult patients who required placement of an invasive intracranial monitor as part of their clinical care. One certified sonographer/physician performed all ultrasounds within 24 hours of placement of EVD. The sonographer was blinded to the ICP recorded by invasive monitor at the time of the scan. A mean ONSD value of ≥5.2 mm was taken as positive. RESULTS: The sonographer performed 27 ocular ultrasounds on individual patients. Six (22%) of these patients had eICP (EVD measurement of >20 mmHg). Spearman rank correlation coefficient of ONSD and ICP was 0.408 (p=0.03), demonstrating a moderate positive correlation. A ROC curve was created to determine the optimal cut off value to distinguish an eICP greater than 20 mmHg. The area under the receiver operator characteristic curve was 0.8712 (95% confidence interval [CI]=0.67 to 0.96). ONSD ≥5.2 mm was a good predictor of eICP (>20 mmHg) with a sensitivity of 83.3% (95% CI=35.9% to 99.6%) and specificity of 100% (95% CI=84.6% to 100%). CONCLUSION: While the study suggests ONSD measurements performed by a single skilled operator may be both sensitive and specific for detecting eICP, confirmation in a much larger sample is needed. Ocular ultrasound may provide additional non-invasive means of assessing eICP. Department of Emergency Medicine, University of California, Irvine School of Medicine 2014-03 /pmc/articles/PMC3966440/ /pubmed/24672615 http://dx.doi.org/10.5811/westjem.2013.9.16191 Text en Copyright © 2014 the authors. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) License. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Technology in Emergency Medicine Care Frumin, Erica Schlang, Joelle Wiechmann, Warren Hata, Stacy Rosen, Sasha Anderson, Craig Pare, Laura Rosen, Mark Fox, John Christian Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure |
title | Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure |
title_full | Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure |
title_fullStr | Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure |
title_full_unstemmed | Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure |
title_short | Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure |
title_sort | prospective analysis of single operator sonographic optic nerve sheath diameter measurement for diagnosis of elevated intracranial pressure |
topic | Technology in Emergency Medicine Care |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3966440/ https://www.ncbi.nlm.nih.gov/pubmed/24672615 http://dx.doi.org/10.5811/westjem.2013.9.16191 |
work_keys_str_mv | AT fruminerica prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT schlangjoelle prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT wiechmannwarren prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT hatastacy prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT rosensasha prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT andersoncraig prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT parelaura prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT rosenmark prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure AT foxjohnchristian prospectiveanalysisofsingleoperatorsonographicopticnervesheathdiametermeasurementfordiagnosisofelevatedintracranialpressure |