Cargando…

Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography

We report the case of a patient with recurrent acute angle-closure glaucoma who had undergone a previous laser iridotomy. Because the initial iridotomy was small, patency could not be determined by slit-lamp examination. Therefore, anterior-segment optical coherence tomography was used to evaluate t...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakabayashi, Seigo, Kawai, Motofumi, Yamaguchi, Toru, Yoshida, Akitoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3968079/
https://www.ncbi.nlm.nih.gov/pubmed/24711692
http://dx.doi.org/10.2147/OPTH.S60405
_version_ 1782309110431088640
author Nakabayashi, Seigo
Kawai, Motofumi
Yamaguchi, Toru
Yoshida, Akitoshi
author_facet Nakabayashi, Seigo
Kawai, Motofumi
Yamaguchi, Toru
Yoshida, Akitoshi
author_sort Nakabayashi, Seigo
collection PubMed
description We report the case of a patient with recurrent acute angle-closure glaucoma who had undergone a previous laser iridotomy. Because the initial iridotomy was small, patency could not be determined by slit-lamp examination. Therefore, anterior-segment optical coherence tomography was used to evaluate the patency. Cross-sectional images showed the presence of a membrane with an anterior bowing configuration at the base of the iridotomy, suggesting that recurrent pupillary block was the causative mechanism. A repeat laser iridotomy was performed, with a resultant decrease in the intraocular pressure and widening of the anterior chamber angle. Anterior-segment optical coherence tomography may be helpful to confirm the status of a laser iridotomy, especially when the iridotomy is small.
format Online
Article
Text
id pubmed-3968079
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-39680792014-04-07 Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography Nakabayashi, Seigo Kawai, Motofumi Yamaguchi, Toru Yoshida, Akitoshi Clin Ophthalmol Case Report We report the case of a patient with recurrent acute angle-closure glaucoma who had undergone a previous laser iridotomy. Because the initial iridotomy was small, patency could not be determined by slit-lamp examination. Therefore, anterior-segment optical coherence tomography was used to evaluate the patency. Cross-sectional images showed the presence of a membrane with an anterior bowing configuration at the base of the iridotomy, suggesting that recurrent pupillary block was the causative mechanism. A repeat laser iridotomy was performed, with a resultant decrease in the intraocular pressure and widening of the anterior chamber angle. Anterior-segment optical coherence tomography may be helpful to confirm the status of a laser iridotomy, especially when the iridotomy is small. Dove Medical Press 2014-03-21 /pmc/articles/PMC3968079/ /pubmed/24711692 http://dx.doi.org/10.2147/OPTH.S60405 Text en © 2014 Nakabayashi et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Case Report
Nakabayashi, Seigo
Kawai, Motofumi
Yamaguchi, Toru
Yoshida, Akitoshi
Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
title Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
title_full Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
title_fullStr Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
title_full_unstemmed Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
title_short Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
title_sort patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3968079/
https://www.ncbi.nlm.nih.gov/pubmed/24711692
http://dx.doi.org/10.2147/OPTH.S60405
work_keys_str_mv AT nakabayashiseigo patencyofsmalllaseriridotomyevaluatedusinganteriorsegmentopticalcoherencetomography
AT kawaimotofumi patencyofsmalllaseriridotomyevaluatedusinganteriorsegmentopticalcoherencetomography
AT yamaguchitoru patencyofsmalllaseriridotomyevaluatedusinganteriorsegmentopticalcoherencetomography
AT yoshidaakitoshi patencyofsmalllaseriridotomyevaluatedusinganteriorsegmentopticalcoherencetomography