Cargando…

Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses

OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare t...

Descripción completa

Detalles Bibliográficos
Autores principales: Buen, Eliseo Portilla-de, Orozco-Mosqueda, Abel, Leal-Cortés, Caridad, Vázquez-Camacho, Gonzalo, Fuentes-Orozco, Clotilde, Alvarez-Villaseñor, Andrea Socorro, Macías-Amezcua, Michel Dassaejv, González-Ojeda, Alejandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3971357/
https://www.ncbi.nlm.nih.gov/pubmed/24714834
http://dx.doi.org/10.6061/clinics/2014(04)07
_version_ 1782309464906399744
author Buen, Eliseo Portilla-de
Orozco-Mosqueda, Abel
Leal-Cortés, Caridad
Vázquez-Camacho, Gonzalo
Fuentes-Orozco, Clotilde
Alvarez-Villaseñor, Andrea Socorro
Macías-Amezcua, Michel Dassaejv
González-Ojeda, Alejandro
author_facet Buen, Eliseo Portilla-de
Orozco-Mosqueda, Abel
Leal-Cortés, Caridad
Vázquez-Camacho, Gonzalo
Fuentes-Orozco, Clotilde
Alvarez-Villaseñor, Andrea Socorro
Macías-Amezcua, Michel Dassaejv
González-Ojeda, Alejandro
author_sort Buen, Eliseo Portilla-de
collection PubMed
description OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats. METHODS: Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g) treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal) or high-risk (ischemic) end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL) or low (40 mg/mL) concentrations and thrombin at high (1000 IU/mL) or low (500 IU/mL) concentrations. RESULTS: Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis. CONCLUSIONS: Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery.
format Online
Article
Text
id pubmed-3971357
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-39713572014-04-02 Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses Buen, Eliseo Portilla-de Orozco-Mosqueda, Abel Leal-Cortés, Caridad Vázquez-Camacho, Gonzalo Fuentes-Orozco, Clotilde Alvarez-Villaseñor, Andrea Socorro Macías-Amezcua, Michel Dassaejv González-Ojeda, Alejandro Clinics (Sao Paulo) Basic Research OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats. METHODS: Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g) treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal) or high-risk (ischemic) end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL) or low (40 mg/mL) concentrations and thrombin at high (1000 IU/mL) or low (500 IU/mL) concentrations. RESULTS: Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis. CONCLUSIONS: Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2014-04 /pmc/articles/PMC3971357/ /pubmed/24714834 http://dx.doi.org/10.6061/clinics/2014(04)07 Text en Copyright © 2014 Hospital das Clínicas da FMUSP http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Basic Research
Buen, Eliseo Portilla-de
Orozco-Mosqueda, Abel
Leal-Cortés, Caridad
Vázquez-Camacho, Gonzalo
Fuentes-Orozco, Clotilde
Alvarez-Villaseñor, Andrea Socorro
Macías-Amezcua, Michel Dassaejv
González-Ojeda, Alejandro
Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
title Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
title_full Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
title_fullStr Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
title_full_unstemmed Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
title_short Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
title_sort fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses
topic Basic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3971357/
https://www.ncbi.nlm.nih.gov/pubmed/24714834
http://dx.doi.org/10.6061/clinics/2014(04)07
work_keys_str_mv AT bueneliseoportillade fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT orozcomosquedaabel fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT lealcortescaridad fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT vazquezcamachogonzalo fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT fuentesorozcoclotilde fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT alvarezvillasenorandreasocorro fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT maciasamezcuamicheldassaejv fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses
AT gonzalezojedaalejandro fibrinogenandthrombinconcentrationsarecriticalforfibringlueadherenceinrathighriskcolonanastomoses