Cargando…

The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial

BACKGROUND: It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compare...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Ah-Young, Jeon, Young-Tae, Choi, Eun-Joo, Ryu, Jung-Hee, Hwang, Jung-Won, Park, Hee-Pyoung, Do, Sang-Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3975933/
https://www.ncbi.nlm.nih.gov/pubmed/24581318
http://dx.doi.org/10.1186/1471-2253-14-11
_version_ 1782310211764092928
author Oh, Ah-Young
Jeon, Young-Tae
Choi, Eun-Joo
Ryu, Jung-Hee
Hwang, Jung-Won
Park, Hee-Pyoung
Do, Sang-Hwan
author_facet Oh, Ah-Young
Jeon, Young-Tae
Choi, Eun-Joo
Ryu, Jung-Hee
Hwang, Jung-Won
Park, Hee-Pyoung
Do, Sang-Hwan
author_sort Oh, Ah-Young
collection PubMed
description BACKGROUND: It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method. METHODS: Sixty adult patients who required subclavian venous catheterization for neurosurgery were enrolled in this prospective randomized controlled study. Patients were randomly divided into a landmark group (n = 30) or an ultrasound group (n = 30). After the subclavian vein was punctured, the guidewire was advanced with the guidewire J-tip directed cephalad. Misplacement or advancement failure of the guidewire was regarded as an unsuccessful placement. Postoperative chest radiography was performed to confirm pneumothorax and the location of the catheter tip. RESULTS: The two groups were comparable with respect to age, gender, height, and weight distribution. The incidence of unsuccessful guidewire placement was lower in the ultrasound group than in the landmark group (13% vs. 47%, P = 0.01). Among the unsuccessful guidewire placements, the incidence of misplacement were comparable between the groups and were all located in the ipsilateral internal jugular vein (7% vs. 7%). However, the incidence of advancement failure was significantly higher in landmark group (40% vs. 7%, P = 0.005). There were no complications such as pneumothorax or hemothorax. CONCLUSIONS: The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach.
format Online
Article
Text
id pubmed-3975933
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39759332014-04-05 The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial Oh, Ah-Young Jeon, Young-Tae Choi, Eun-Joo Ryu, Jung-Hee Hwang, Jung-Won Park, Hee-Pyoung Do, Sang-Hwan BMC Anesthesiol Research Article BACKGROUND: It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method. METHODS: Sixty adult patients who required subclavian venous catheterization for neurosurgery were enrolled in this prospective randomized controlled study. Patients were randomly divided into a landmark group (n = 30) or an ultrasound group (n = 30). After the subclavian vein was punctured, the guidewire was advanced with the guidewire J-tip directed cephalad. Misplacement or advancement failure of the guidewire was regarded as an unsuccessful placement. Postoperative chest radiography was performed to confirm pneumothorax and the location of the catheter tip. RESULTS: The two groups were comparable with respect to age, gender, height, and weight distribution. The incidence of unsuccessful guidewire placement was lower in the ultrasound group than in the landmark group (13% vs. 47%, P = 0.01). Among the unsuccessful guidewire placements, the incidence of misplacement were comparable between the groups and were all located in the ipsilateral internal jugular vein (7% vs. 7%). However, the incidence of advancement failure was significantly higher in landmark group (40% vs. 7%, P = 0.005). There were no complications such as pneumothorax or hemothorax. CONCLUSIONS: The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach. BioMed Central 2014-02-28 /pmc/articles/PMC3975933/ /pubmed/24581318 http://dx.doi.org/10.1186/1471-2253-14-11 Text en Copyright © 2014 Oh et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Research Article
Oh, Ah-Young
Jeon, Young-Tae
Choi, Eun-Joo
Ryu, Jung-Hee
Hwang, Jung-Won
Park, Hee-Pyoung
Do, Sang-Hwan
The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
title The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
title_full The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
title_fullStr The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
title_full_unstemmed The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
title_short The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
title_sort influence of the direction of j-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3975933/
https://www.ncbi.nlm.nih.gov/pubmed/24581318
http://dx.doi.org/10.1186/1471-2253-14-11
work_keys_str_mv AT ohahyoung theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT jeonyoungtae theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT choieunjoo theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT ryujunghee theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT hwangjungwon theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT parkheepyoung theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT dosanghwan theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT ohahyoung influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT jeonyoungtae influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT choieunjoo influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT ryujunghee influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT hwangjungwon influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT parkheepyoung influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial
AT dosanghwan influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial