The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
BACKGROUND: It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compare...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3975933/ https://www.ncbi.nlm.nih.gov/pubmed/24581318 http://dx.doi.org/10.1186/1471-2253-14-11 |
_version_ | 1782310211764092928 |
---|---|
author | Oh, Ah-Young Jeon, Young-Tae Choi, Eun-Joo Ryu, Jung-Hee Hwang, Jung-Won Park, Hee-Pyoung Do, Sang-Hwan |
author_facet | Oh, Ah-Young Jeon, Young-Tae Choi, Eun-Joo Ryu, Jung-Hee Hwang, Jung-Won Park, Hee-Pyoung Do, Sang-Hwan |
author_sort | Oh, Ah-Young |
collection | PubMed |
description | BACKGROUND: It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method. METHODS: Sixty adult patients who required subclavian venous catheterization for neurosurgery were enrolled in this prospective randomized controlled study. Patients were randomly divided into a landmark group (n = 30) or an ultrasound group (n = 30). After the subclavian vein was punctured, the guidewire was advanced with the guidewire J-tip directed cephalad. Misplacement or advancement failure of the guidewire was regarded as an unsuccessful placement. Postoperative chest radiography was performed to confirm pneumothorax and the location of the catheter tip. RESULTS: The two groups were comparable with respect to age, gender, height, and weight distribution. The incidence of unsuccessful guidewire placement was lower in the ultrasound group than in the landmark group (13% vs. 47%, P = 0.01). Among the unsuccessful guidewire placements, the incidence of misplacement were comparable between the groups and were all located in the ipsilateral internal jugular vein (7% vs. 7%). However, the incidence of advancement failure was significantly higher in landmark group (40% vs. 7%, P = 0.005). There were no complications such as pneumothorax or hemothorax. CONCLUSIONS: The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach. |
format | Online Article Text |
id | pubmed-3975933 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-39759332014-04-05 The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial Oh, Ah-Young Jeon, Young-Tae Choi, Eun-Joo Ryu, Jung-Hee Hwang, Jung-Won Park, Hee-Pyoung Do, Sang-Hwan BMC Anesthesiol Research Article BACKGROUND: It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method. METHODS: Sixty adult patients who required subclavian venous catheterization for neurosurgery were enrolled in this prospective randomized controlled study. Patients were randomly divided into a landmark group (n = 30) or an ultrasound group (n = 30). After the subclavian vein was punctured, the guidewire was advanced with the guidewire J-tip directed cephalad. Misplacement or advancement failure of the guidewire was regarded as an unsuccessful placement. Postoperative chest radiography was performed to confirm pneumothorax and the location of the catheter tip. RESULTS: The two groups were comparable with respect to age, gender, height, and weight distribution. The incidence of unsuccessful guidewire placement was lower in the ultrasound group than in the landmark group (13% vs. 47%, P = 0.01). Among the unsuccessful guidewire placements, the incidence of misplacement were comparable between the groups and were all located in the ipsilateral internal jugular vein (7% vs. 7%). However, the incidence of advancement failure was significantly higher in landmark group (40% vs. 7%, P = 0.005). There were no complications such as pneumothorax or hemothorax. CONCLUSIONS: The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach. BioMed Central 2014-02-28 /pmc/articles/PMC3975933/ /pubmed/24581318 http://dx.doi.org/10.1186/1471-2253-14-11 Text en Copyright © 2014 Oh et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Research Article Oh, Ah-Young Jeon, Young-Tae Choi, Eun-Joo Ryu, Jung-Hee Hwang, Jung-Won Park, Hee-Pyoung Do, Sang-Hwan The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
title | The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
title_full | The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
title_fullStr | The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
title_full_unstemmed | The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
title_short | The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
title_sort | influence of the direction of j-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3975933/ https://www.ncbi.nlm.nih.gov/pubmed/24581318 http://dx.doi.org/10.1186/1471-2253-14-11 |
work_keys_str_mv | AT ohahyoung theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT jeonyoungtae theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT choieunjoo theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT ryujunghee theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT hwangjungwon theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT parkheepyoung theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT dosanghwan theinfluenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT ohahyoung influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT jeonyoungtae influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT choieunjoo influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT ryujunghee influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT hwangjungwon influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT parkheepyoung influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial AT dosanghwan influenceofthedirectionofjtipontheplacementofasubclaviancatheterrealtimeultrasoundguidedcannulationversuslandmarkmethodarandomizedcontrolledtrial |