Cargando…
Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures
Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduc...
Autores principales: | Doht, Stefanie, Meffert, Rainer H., Raschke, Michael J., Blunk, Torsten, Ochman, Sabine |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3976824/ https://www.ncbi.nlm.nih.gov/pubmed/24757429 http://dx.doi.org/10.1155/2014/648787 |
Ejemplares similares
-
Experimental Fracture Model versus Osteotomy Model in Metacarpal Bone Plate Fixation
por: Ochman, S., et al.
Publicado: (2011) -
Biomechanical analysis of different osteosyntheses and the combination with bone substitute in tibial head depression fractures
por: Jordan, Martin C., et al.
Publicado: (2016) -
Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures
por: Ho, Tsung-Yu, et al.
Publicado: (2023) -
Bunnell or cross-lock Bunnell suture for tendon repair? Defining the biomechanical role of suture pretension
por: Jordan, Martin C., et al.
Publicado: (2015) -
Biomechanical Evaluation of Promising Different Bone Substitutes in a Clinically Relevant Test Set-Up
por: Brueckner, Theresa, et al.
Publicado: (2019)