Cargando…

A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur

Statement of Problem: Laser irradiation makes structural and chemical changes on the dental hard tissues. These changes alter the level of solubility and permeability of dentin. Purpose: The aim of this study was to compare the microhardness and the structural changes in the dentin cavity floor prep...

Descripción completa

Detalles Bibliográficos
Autores principales: Arbabzadeh, F, Birang, E, Nazem, R, Abbasian, M, Koosha, F, Birang, R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3977546/
https://www.ncbi.nlm.nih.gov/pubmed/24724123
_version_ 1782310438397018112
author Arbabzadeh, F
Birang, E
Nazem, R
Abbasian, M
Koosha, F
Birang, R
author_facet Arbabzadeh, F
Birang, E
Nazem, R
Abbasian, M
Koosha, F
Birang, R
author_sort Arbabzadeh, F
collection PubMed
description Statement of Problem: Laser irradiation makes structural and chemical changes on the dental hard tissues. These changes alter the level of solubility and permeability of dentin. Purpose: The aim of this study was to compare the microhardness and the structural changes in the dentin cavity floor prepared with Er: YAG laser and bur. Material and Methods: In this experimental study, fifteen intact human molars were selected. Two square cavities were prepared on the buccal and lingual surfaces of each tooth. One side was randomly prepared by Er:YAG laser and the other side by bur. The specimens were divided into two halves. Consequently, there were 30 samples in every group. One half was assigned for the Vickers’s hardness test and the other one, for determination of Ca and P percentage and atomic elements analysis. The data were analyzed by Paired T-tests through SPSS16 (α≤o.o5). Results: The means and the standard deviation of the microhardness were 69.77±25.62 and 51.33±9.31 Kg/mm(2) in the laser and bur groups, respectively. Statistical analysis showed significant differences between the two groups (p=0.017). Weight percentage of calcium in the laser cavity (65.5) was less than the bur cavities (68.21) and the difference was significant (p= 0.037). Conclusion: The hardness of dentin in laser group was higher than the bur group because of the higher mineral content of the dentin. The hardness and the mineral content of dentin are important factors in the bonding effectiveness of the dental materials so with laser cavity preparation, good mineral substrate are available for a better bonding.
format Online
Article
Text
id pubmed-3977546
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-39775462014-04-10 A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur Arbabzadeh, F Birang, E Nazem, R Abbasian, M Koosha, F Birang, R J Dent (Shiraz) Original Article Statement of Problem: Laser irradiation makes structural and chemical changes on the dental hard tissues. These changes alter the level of solubility and permeability of dentin. Purpose: The aim of this study was to compare the microhardness and the structural changes in the dentin cavity floor prepared with Er: YAG laser and bur. Material and Methods: In this experimental study, fifteen intact human molars were selected. Two square cavities were prepared on the buccal and lingual surfaces of each tooth. One side was randomly prepared by Er:YAG laser and the other side by bur. The specimens were divided into two halves. Consequently, there were 30 samples in every group. One half was assigned for the Vickers’s hardness test and the other one, for determination of Ca and P percentage and atomic elements analysis. The data were analyzed by Paired T-tests through SPSS16 (α≤o.o5). Results: The means and the standard deviation of the microhardness were 69.77±25.62 and 51.33±9.31 Kg/mm(2) in the laser and bur groups, respectively. Statistical analysis showed significant differences between the two groups (p=0.017). Weight percentage of calcium in the laser cavity (65.5) was less than the bur cavities (68.21) and the difference was significant (p= 0.037). Conclusion: The hardness of dentin in laser group was higher than the bur group because of the higher mineral content of the dentin. The hardness and the mineral content of dentin are important factors in the bonding effectiveness of the dental materials so with laser cavity preparation, good mineral substrate are available for a better bonding. Shiraz University of Medical Sciences 2013-06 /pmc/articles/PMC3977546/ /pubmed/24724123 Text en © 2013: Journal of dentistry (Shiraz, Iran) This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Arbabzadeh, F
Birang, E
Nazem, R
Abbasian, M
Koosha, F
Birang, R
A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur
title A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur
title_full A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur
title_fullStr A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur
title_full_unstemmed A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur
title_short A Comparative Study on Micro Hardness and Structural Changes of Dentin Floor Cavity Prepared by Er: YAG Laser Irradiation and Mechanical Bur
title_sort comparative study on micro hardness and structural changes of dentin floor cavity prepared by er: yag laser irradiation and mechanical bur
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3977546/
https://www.ncbi.nlm.nih.gov/pubmed/24724123
work_keys_str_mv AT arbabzadehf acomparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT birange acomparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT nazemr acomparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT abbasianm acomparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT kooshaf acomparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT birangr acomparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT arbabzadehf comparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT birange comparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT nazemr comparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT abbasianm comparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT kooshaf comparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur
AT birangr comparativestudyonmicrohardnessandstructuralchangesofdentinfloorcavitypreparedbyeryaglaserirradiationandmechanicalbur