Cargando…
Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test
Speckle tracking echocardiography (STE) is a method of quantitative assessment of myocardial function complementary to ejection fraction and visual evaluation. Standard STE analysis, demands manual tracing of the myocardium whereas automated function imaging (AFI) offers more convenient (based on se...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3978222/ https://www.ncbi.nlm.nih.gov/pubmed/24522406 http://dx.doi.org/10.1007/s10554-014-0386-z |
_version_ | 1782310526912561152 |
---|---|
author | Wierzbowska-Drabik, Karina Hamala, Piotr Roszczyk, Nikolina Lipiec, Piotr Plewka, Michał Kręcki, Radosław Kasprzak, Jarosław Damian |
author_facet | Wierzbowska-Drabik, Karina Hamala, Piotr Roszczyk, Nikolina Lipiec, Piotr Plewka, Michał Kręcki, Radosław Kasprzak, Jarosław Damian |
author_sort | Wierzbowska-Drabik, Karina |
collection | PubMed |
description | Speckle tracking echocardiography (STE) is a method of quantitative assessment of myocardial function complementary to ejection fraction and visual evaluation. Standard STE analysis, demands manual tracing of the myocardium whereas automated function imaging (AFI) offers more convenient (based on selection of three points) assessment of longitudinal strain. Nevertheless, feasibility and correlation between both methods were not thoroughly examined, especially during tachycardia at peak stage of dobutamine stress echocardiography (DSE). We performed DSE in 238 patients (pts) with recording of apical views during baseline (0) and peak (1) DSE and analyzed them by STE and AFI. According to angiography, 127/238 pts had significant (≥70 %) lesions in coronary arteries. We assessed correlations between STE and AFI derived peak systolic longitudinal strain values for global and regional parameters, feasibility, time of analysis and interobserver agreement. Global systolic longitudinal strain measured during baseline and peak stage of DSE by AFI showed very good correlation with standard STE parameters, with correlation coefficients r = 0.90 and r = 0.86 respectively (p < 0.0001). For regional parameters correlation coefficients ranged from 0.83 to 0.85 for baseline and from 0.70 to 0.79 for peak DSE. Both methods provided good and similar feasibility with only 1 % segments excluded from analysis at peak stage of DSE with shorter time and lower coefficient of variance offered by AFI. Global and regional longitudinal strain achieved by faster and less operator-dependent AFI method correlate well with standard more time-consuming STE analysis during baseline and peak stage of DSE. |
format | Online Article Text |
id | pubmed-3978222 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-39782222014-04-22 Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test Wierzbowska-Drabik, Karina Hamala, Piotr Roszczyk, Nikolina Lipiec, Piotr Plewka, Michał Kręcki, Radosław Kasprzak, Jarosław Damian Int J Cardiovasc Imaging Original Paper Speckle tracking echocardiography (STE) is a method of quantitative assessment of myocardial function complementary to ejection fraction and visual evaluation. Standard STE analysis, demands manual tracing of the myocardium whereas automated function imaging (AFI) offers more convenient (based on selection of three points) assessment of longitudinal strain. Nevertheless, feasibility and correlation between both methods were not thoroughly examined, especially during tachycardia at peak stage of dobutamine stress echocardiography (DSE). We performed DSE in 238 patients (pts) with recording of apical views during baseline (0) and peak (1) DSE and analyzed them by STE and AFI. According to angiography, 127/238 pts had significant (≥70 %) lesions in coronary arteries. We assessed correlations between STE and AFI derived peak systolic longitudinal strain values for global and regional parameters, feasibility, time of analysis and interobserver agreement. Global systolic longitudinal strain measured during baseline and peak stage of DSE by AFI showed very good correlation with standard STE parameters, with correlation coefficients r = 0.90 and r = 0.86 respectively (p < 0.0001). For regional parameters correlation coefficients ranged from 0.83 to 0.85 for baseline and from 0.70 to 0.79 for peak DSE. Both methods provided good and similar feasibility with only 1 % segments excluded from analysis at peak stage of DSE with shorter time and lower coefficient of variance offered by AFI. Global and regional longitudinal strain achieved by faster and less operator-dependent AFI method correlate well with standard more time-consuming STE analysis during baseline and peak stage of DSE. Springer Netherlands 2014-02-13 2014 /pmc/articles/PMC3978222/ /pubmed/24522406 http://dx.doi.org/10.1007/s10554-014-0386-z Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Paper Wierzbowska-Drabik, Karina Hamala, Piotr Roszczyk, Nikolina Lipiec, Piotr Plewka, Michał Kręcki, Radosław Kasprzak, Jarosław Damian Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
title | Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
title_full | Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
title_fullStr | Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
title_full_unstemmed | Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
title_short | Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
title_sort | feasibility and correlation of standard 2d speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3978222/ https://www.ncbi.nlm.nih.gov/pubmed/24522406 http://dx.doi.org/10.1007/s10554-014-0386-z |
work_keys_str_mv | AT wierzbowskadrabikkarina feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest AT hamalapiotr feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest AT roszczyknikolina feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest AT lipiecpiotr feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest AT plewkamichał feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest AT kreckiradosław feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest AT kasprzakjarosławdamian feasibilityandcorrelationofstandard2dspeckletrackingechocardiographyandautomatedfunctionimagingderivedparametersofleftventricularfunctionduringdobutaminestresstest |