Cargando…
Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data
Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT) volume data and to evaluate its feasibility. Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3981487/ https://www.ncbi.nlm.nih.gov/pubmed/24782922 http://dx.doi.org/10.1155/2014/495084 |
_version_ | 1782311055794372608 |
---|---|
author | Nemoto, Mitsutaka Yeernuer, Tusufuhan Masutani, Yoshitaka Nomura, Yukihiro Hanaoka, Shouhei Miki, Soichiro Yoshikawa, Takeharu Hayashi, Naoto Ohtomo, Kuni |
author_facet | Nemoto, Mitsutaka Yeernuer, Tusufuhan Masutani, Yoshitaka Nomura, Yukihiro Hanaoka, Shouhei Miki, Soichiro Yoshikawa, Takeharu Hayashi, Naoto Ohtomo, Kuni |
author_sort | Nemoto, Mitsutaka |
collection | PubMed |
description | Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT) volume data and to evaluate its feasibility. Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30) in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume. Results. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999. Conclusions. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy. |
format | Online Article Text |
id | pubmed-3981487 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-39814872014-04-29 Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data Nemoto, Mitsutaka Yeernuer, Tusufuhan Masutani, Yoshitaka Nomura, Yukihiro Hanaoka, Shouhei Miki, Soichiro Yoshikawa, Takeharu Hayashi, Naoto Ohtomo, Kuni J Obes Research Article Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT) volume data and to evaluate its feasibility. Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30) in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume. Results. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999. Conclusions. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy. Hindawi Publishing Corporation 2014 2014-03-20 /pmc/articles/PMC3981487/ /pubmed/24782922 http://dx.doi.org/10.1155/2014/495084 Text en Copyright © 2014 Mitsutaka Nemoto et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Nemoto, Mitsutaka Yeernuer, Tusufuhan Masutani, Yoshitaka Nomura, Yukihiro Hanaoka, Shouhei Miki, Soichiro Yoshikawa, Takeharu Hayashi, Naoto Ohtomo, Kuni Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data |
title | Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data |
title_full | Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data |
title_fullStr | Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data |
title_full_unstemmed | Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data |
title_short | Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data |
title_sort | development of automatic visceral fat volume calculation software for ct volume data |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3981487/ https://www.ncbi.nlm.nih.gov/pubmed/24782922 http://dx.doi.org/10.1155/2014/495084 |
work_keys_str_mv | AT nemotomitsutaka developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT yeernuertusufuhan developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT masutaniyoshitaka developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT nomurayukihiro developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT hanaokashouhei developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT mikisoichiro developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT yoshikawatakeharu developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT hayashinaoto developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata AT ohtomokuni developmentofautomaticvisceralfatvolumecalculationsoftwareforctvolumedata |