Cargando…

Hemostasis in brain tumor surgery using the Aquamantys system

BACKGROUND: Adequate hemostasis in cranial and spinal tumor surgery is of paramount importance in neurosurgical practice. Generalized ooze bleeding from the surgical walls cavity, coming from neoplastic vessels or nervous tissue, may be problematic. Recent technical advances have dramatically reduce...

Descripción completa

Detalles Bibliográficos
Autores principales: Grasso, Giovanni, Giambartino, Filippo, Iacopino, Domenico G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3981681/
https://www.ncbi.nlm.nih.gov/pubmed/24686845
http://dx.doi.org/10.12659/MSM.890583
_version_ 1782311087445639168
author Grasso, Giovanni
Giambartino, Filippo
Iacopino, Domenico G.
author_facet Grasso, Giovanni
Giambartino, Filippo
Iacopino, Domenico G.
author_sort Grasso, Giovanni
collection PubMed
description BACKGROUND: Adequate hemostasis in cranial and spinal tumor surgery is of paramount importance in neurosurgical practice. Generalized ooze bleeding from the surgical walls cavity, coming from neoplastic vessels or nervous tissue, may be problematic. Recent technical advances have dramatically reduced intraoperative complications related to blood loss. Several techniques are usually employed to control hemostasis in tumor surgery, including preoperative embolization, intraoperative hypotension, electrical coagulation, and local application of fibrin sealants or hemostatic matrix, which influence coagulation. MATERIAL/METHODS: Our aim in this study was to evaluate the efficacy and the safety of the Aquamantys(®) system (Medtronic Advanced Energy, Portsmouth, NH, USA), a novel bipolar coagulation device that incorporates a new bipolar coagulation technique. This device has been used in 10 consecutive patients affected by cerebral tumor along with the standard microsurgical technique and well-known intraoperative tools. The technique is associated with simultaneous delivery of bipolar radio frequency energy and conductive fluid through its electrode tip. The volume of saline passing by the electrode tip prevents charring and maintains a clean tip. This cools the tissue as it raises the temperature sufficiently to shrink the collagen of veins and arteries. RESULTS: Effective hemostasis was achieved in all the cases. No complications or unwanted reactions associated with the device have been observed. CONCLUSIONS: Our findings suggest that the Aquamantys(®) system may be a highly effective adjuvant tool in minimizing blood loss in a patient with brain tumor, as well as reducing time of surgery.
format Online
Article
Text
id pubmed-3981681
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-39816812014-04-10 Hemostasis in brain tumor surgery using the Aquamantys system Grasso, Giovanni Giambartino, Filippo Iacopino, Domenico G. Med Sci Monit Product Investigations BACKGROUND: Adequate hemostasis in cranial and spinal tumor surgery is of paramount importance in neurosurgical practice. Generalized ooze bleeding from the surgical walls cavity, coming from neoplastic vessels or nervous tissue, may be problematic. Recent technical advances have dramatically reduced intraoperative complications related to blood loss. Several techniques are usually employed to control hemostasis in tumor surgery, including preoperative embolization, intraoperative hypotension, electrical coagulation, and local application of fibrin sealants or hemostatic matrix, which influence coagulation. MATERIAL/METHODS: Our aim in this study was to evaluate the efficacy and the safety of the Aquamantys(®) system (Medtronic Advanced Energy, Portsmouth, NH, USA), a novel bipolar coagulation device that incorporates a new bipolar coagulation technique. This device has been used in 10 consecutive patients affected by cerebral tumor along with the standard microsurgical technique and well-known intraoperative tools. The technique is associated with simultaneous delivery of bipolar radio frequency energy and conductive fluid through its electrode tip. The volume of saline passing by the electrode tip prevents charring and maintains a clean tip. This cools the tissue as it raises the temperature sufficiently to shrink the collagen of veins and arteries. RESULTS: Effective hemostasis was achieved in all the cases. No complications or unwanted reactions associated with the device have been observed. CONCLUSIONS: Our findings suggest that the Aquamantys(®) system may be a highly effective adjuvant tool in minimizing blood loss in a patient with brain tumor, as well as reducing time of surgery. International Scientific Literature, Inc. 2014-04-01 /pmc/articles/PMC3981681/ /pubmed/24686845 http://dx.doi.org/10.12659/MSM.890583 Text en © Med Sci Monit, 2014 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License
spellingShingle Product Investigations
Grasso, Giovanni
Giambartino, Filippo
Iacopino, Domenico G.
Hemostasis in brain tumor surgery using the Aquamantys system
title Hemostasis in brain tumor surgery using the Aquamantys system
title_full Hemostasis in brain tumor surgery using the Aquamantys system
title_fullStr Hemostasis in brain tumor surgery using the Aquamantys system
title_full_unstemmed Hemostasis in brain tumor surgery using the Aquamantys system
title_short Hemostasis in brain tumor surgery using the Aquamantys system
title_sort hemostasis in brain tumor surgery using the aquamantys system
topic Product Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3981681/
https://www.ncbi.nlm.nih.gov/pubmed/24686845
http://dx.doi.org/10.12659/MSM.890583
work_keys_str_mv AT grassogiovanni hemostasisinbraintumorsurgeryusingtheaquamantyssystem
AT giambartinofilippo hemostasisinbraintumorsurgeryusingtheaquamantyssystem
AT iacopinodomenicog hemostasisinbraintumorsurgeryusingtheaquamantyssystem