Cargando…

Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein

[Image: see text] LC–MS provides a promising alternative to ligand-binding assays for quantification of therapeutic proteins and biomarkers. As LC–MS methodology is based on the analysis of proteolytic peptides, calibration approaches utilizing various calibrators and internal standards (I.S.) have...

Descripción completa

Detalles Bibliográficos
Autores principales: Nouri-Nigjeh, Eslam, Zhang, Ming, Ji, Tao, Yu, Haoying, An, Bo, Duan, Xiaotao, Balthasar, Joseph, Johnson, Robert W., Qu, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3982980/
https://www.ncbi.nlm.nih.gov/pubmed/24611550
http://dx.doi.org/10.1021/ac5001477
_version_ 1782311234913173504
author Nouri-Nigjeh, Eslam
Zhang, Ming
Ji, Tao
Yu, Haoying
An, Bo
Duan, Xiaotao
Balthasar, Joseph
Johnson, Robert W.
Qu, Jun
author_facet Nouri-Nigjeh, Eslam
Zhang, Ming
Ji, Tao
Yu, Haoying
An, Bo
Duan, Xiaotao
Balthasar, Joseph
Johnson, Robert W.
Qu, Jun
author_sort Nouri-Nigjeh, Eslam
collection PubMed
description [Image: see text] LC–MS provides a promising alternative to ligand-binding assays for quantification of therapeutic proteins and biomarkers. As LC–MS methodology is based on the analysis of proteolytic peptides, calibration approaches utilizing various calibrators and internal standards (I.S.) have been developed. A comprehensive assessment of the accuracy and reliability of these approaches is essential but has yet been reported. Here we performed a well-controlled and systematic comparative study using quantification of monoclonal-antibody in plasma as the model system. Method development utilized a high-throughput orthogonal-array-optimization, and two sensitive and stable signature-peptides (SP) from different domains were selected based on extensive evaluations in plasma matrix. With the purities of all protein/peptide standards corrected by quantitative amino acid analysis (AAA), five calibration approaches using stable-isotope-labeled (SIL) I.S. were thoroughly compared, including those at peptide, extended-peptide, and protein levels and two “hybrid” approaches (i.e., protein calibrator with SIL-peptide or SIL-extended-peptide I.S.). These approaches were further evaluated in parallel for a 15 time point, preclinical pharmacokinetic study. All methods showed good precision (CV% < 20%). When examined with protein-spiked plasma QC, peptide-level calibration exhibited severe negative biases (−23 to −62%), highly discordant results between the two SP (deviations of 38–56%), and misleading pharmacokinetics assessments. Extended-peptide calibration showed significant improvements but still with unacceptable accuracy. Conversely, protein-level and the two hybrid calibrations achieved good quantitative accuracy (error < 10%), concordant results by two SP (deviations < 15%), and correct pharmacokinetic parameters. Hybrid approaches were found to provide a cost-effective means for accurate quantification without the costly SIL-protein. Other key findings include (i) using two SP provides a versatile gauge for method reliability; (ii) evaluation of peptide stability in the matrix before SP selection is critical; and (iii) using AAA to verify purities of protein/peptide calibrators ensures accurate quantitation. These results address fundamental calibration issues that have not been adequately investigated in published studies and will provide valuable guidelines for the “fit for purpose” development of accurate LC–MS assays for therapeutic proteins and biomarkers in biological matrices.
format Online
Article
Text
id pubmed-3982980
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-39829802015-03-10 Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein Nouri-Nigjeh, Eslam Zhang, Ming Ji, Tao Yu, Haoying An, Bo Duan, Xiaotao Balthasar, Joseph Johnson, Robert W. Qu, Jun Anal Chem [Image: see text] LC–MS provides a promising alternative to ligand-binding assays for quantification of therapeutic proteins and biomarkers. As LC–MS methodology is based on the analysis of proteolytic peptides, calibration approaches utilizing various calibrators and internal standards (I.S.) have been developed. A comprehensive assessment of the accuracy and reliability of these approaches is essential but has yet been reported. Here we performed a well-controlled and systematic comparative study using quantification of monoclonal-antibody in plasma as the model system. Method development utilized a high-throughput orthogonal-array-optimization, and two sensitive and stable signature-peptides (SP) from different domains were selected based on extensive evaluations in plasma matrix. With the purities of all protein/peptide standards corrected by quantitative amino acid analysis (AAA), five calibration approaches using stable-isotope-labeled (SIL) I.S. were thoroughly compared, including those at peptide, extended-peptide, and protein levels and two “hybrid” approaches (i.e., protein calibrator with SIL-peptide or SIL-extended-peptide I.S.). These approaches were further evaluated in parallel for a 15 time point, preclinical pharmacokinetic study. All methods showed good precision (CV% < 20%). When examined with protein-spiked plasma QC, peptide-level calibration exhibited severe negative biases (−23 to −62%), highly discordant results between the two SP (deviations of 38–56%), and misleading pharmacokinetics assessments. Extended-peptide calibration showed significant improvements but still with unacceptable accuracy. Conversely, protein-level and the two hybrid calibrations achieved good quantitative accuracy (error < 10%), concordant results by two SP (deviations < 15%), and correct pharmacokinetic parameters. Hybrid approaches were found to provide a cost-effective means for accurate quantification without the costly SIL-protein. Other key findings include (i) using two SP provides a versatile gauge for method reliability; (ii) evaluation of peptide stability in the matrix before SP selection is critical; and (iii) using AAA to verify purities of protein/peptide calibrators ensures accurate quantitation. These results address fundamental calibration issues that have not been adequately investigated in published studies and will provide valuable guidelines for the “fit for purpose” development of accurate LC–MS assays for therapeutic proteins and biomarkers in biological matrices. American Chemical Society 2014-03-10 2014-04-01 /pmc/articles/PMC3982980/ /pubmed/24611550 http://dx.doi.org/10.1021/ac5001477 Text en Copyright © 2014 American Chemical Society
spellingShingle Nouri-Nigjeh, Eslam
Zhang, Ming
Ji, Tao
Yu, Haoying
An, Bo
Duan, Xiaotao
Balthasar, Joseph
Johnson, Robert W.
Qu, Jun
Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
title Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
title_full Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
title_fullStr Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
title_full_unstemmed Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
title_short Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
title_sort effects of calibration approaches on the accuracy for lc–ms targeted quantification of therapeutic protein
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3982980/
https://www.ncbi.nlm.nih.gov/pubmed/24611550
http://dx.doi.org/10.1021/ac5001477
work_keys_str_mv AT nourinigjeheslam effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT zhangming effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT jitao effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT yuhaoying effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT anbo effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT duanxiaotao effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT balthasarjoseph effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT johnsonrobertw effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein
AT qujun effectsofcalibrationapproachesontheaccuracyforlcmstargetedquantificationoftherapeuticprotein