Cargando…
Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report
A 28-year-old male patient with occipito-atlanto-axial instability underwent a cervical fusion with posterior technique. Post-operatively, the endotracheal tube (ETT) was removed, and the patient was transferred to the intensive care unit. After transfer, an upper airway obstruction developed and re...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Anesthesiologists
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3983421/ https://www.ncbi.nlm.nih.gov/pubmed/24729847 http://dx.doi.org/10.4097/kjae.2014.66.3.237 |
_version_ | 1782311324621996032 |
---|---|
author | Sung, Joon Kyung Kim, Hyung Gon Kim, Jung Eun Jang, Myung-Soo Kang, Jong-Man |
author_facet | Sung, Joon Kyung Kim, Hyung Gon Kim, Jung Eun Jang, Myung-Soo Kang, Jong-Man |
author_sort | Sung, Joon Kyung |
collection | PubMed |
description | A 28-year-old male patient with occipito-atlanto-axial instability underwent a cervical fusion with posterior technique. Post-operatively, the endotracheal tube (ETT) was removed, and the patient was transferred to the intensive care unit. After transfer, an upper airway obstruction developed and reintubations with a laryngoscope were attempted but failed. We inserted a #4 proseal laryngeal mask airway (LMA) and passed a 5.0 mm ETT through the LMA with the aid of a fiberoptic bronchoscope. We passed a tube exchanger through the 5.0 mm ETT and exchanged it with a 7.5 mm ETT. This method may be a useful alternative for difficult tracheal intubations. |
format | Online Article Text |
id | pubmed-3983421 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-39834212014-04-11 Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report Sung, Joon Kyung Kim, Hyung Gon Kim, Jung Eun Jang, Myung-Soo Kang, Jong-Man Korean J Anesthesiol Case Report A 28-year-old male patient with occipito-atlanto-axial instability underwent a cervical fusion with posterior technique. Post-operatively, the endotracheal tube (ETT) was removed, and the patient was transferred to the intensive care unit. After transfer, an upper airway obstruction developed and reintubations with a laryngoscope were attempted but failed. We inserted a #4 proseal laryngeal mask airway (LMA) and passed a 5.0 mm ETT through the LMA with the aid of a fiberoptic bronchoscope. We passed a tube exchanger through the 5.0 mm ETT and exchanged it with a 7.5 mm ETT. This method may be a useful alternative for difficult tracheal intubations. The Korean Society of Anesthesiologists 2014-03 2014-03-28 /pmc/articles/PMC3983421/ /pubmed/24729847 http://dx.doi.org/10.4097/kjae.2014.66.3.237 Text en Copyright © the Korean Society of Anesthesiologists, 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Sung, Joon Kyung Kim, Hyung Gon Kim, Jung Eun Jang, Myung-Soo Kang, Jong-Man Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
title | Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
title_full | Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
title_fullStr | Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
title_full_unstemmed | Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
title_short | Endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
title_sort | endotracheal tube intubation with the aid of a laryngeal mask airway, a fiberoptic bronchoscope, and a tube exchanger in a difficult airway patient: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3983421/ https://www.ncbi.nlm.nih.gov/pubmed/24729847 http://dx.doi.org/10.4097/kjae.2014.66.3.237 |
work_keys_str_mv | AT sungjoonkyung endotrachealtubeintubationwiththeaidofalaryngealmaskairwayafiberopticbronchoscopeandatubeexchangerinadifficultairwaypatientacasereport AT kimhyunggon endotrachealtubeintubationwiththeaidofalaryngealmaskairwayafiberopticbronchoscopeandatubeexchangerinadifficultairwaypatientacasereport AT kimjungeun endotrachealtubeintubationwiththeaidofalaryngealmaskairwayafiberopticbronchoscopeandatubeexchangerinadifficultairwaypatientacasereport AT jangmyungsoo endotrachealtubeintubationwiththeaidofalaryngealmaskairwayafiberopticbronchoscopeandatubeexchangerinadifficultairwaypatientacasereport AT kangjongman endotrachealtubeintubationwiththeaidofalaryngealmaskairwayafiberopticbronchoscopeandatubeexchangerinadifficultairwaypatientacasereport |