Cargando…

Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation

BACKGROUND: The aim of the present study is to demonstrate, through tests with healthy volunteers, the feasibility of potentially assisting individuals with neurological disorders via a portable assistive technology for the upper extremities (UE). For this purpose the task of independently drinking...

Descripción completa

Detalles Bibliográficos
Autores principales: Looned, Ritik, Webb, Jacob, Xiao, Zheng Gang, Menon, Carlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3983865/
https://www.ncbi.nlm.nih.gov/pubmed/24708603
http://dx.doi.org/10.1186/1743-0003-11-51
_version_ 1782311372962398208
author Looned, Ritik
Webb, Jacob
Xiao, Zheng Gang
Menon, Carlo
author_facet Looned, Ritik
Webb, Jacob
Xiao, Zheng Gang
Menon, Carlo
author_sort Looned, Ritik
collection PubMed
description BACKGROUND: The aim of the present study is to demonstrate, through tests with healthy volunteers, the feasibility of potentially assisting individuals with neurological disorders via a portable assistive technology for the upper extremities (UE). For this purpose the task of independently drinking a glass of water was selected, as it is one of the most basic and vital activities of the daily living that is unfortunately not achievable by individuals severely affected by stroke. METHODS: To accomplish the aim of this study we introduce a wearable and portable system consisting of a novel lightweight Robotic Arm Orthosis (RAO), a Functional Electrical Stimulation (FES) system, and a simple wireless Brain-Computer Interface (BCI). This system is able to process electroencephalographic (EEG) signals and translate them into motions of the impaired arm. Five healthy volunteers participated in this study and were asked to simulate stroke patient symptoms with no voluntary control of their hand and arm. The setup was designed such as the volitional movements of the healthy volunteers’ UE did not interfere with the evaluation of the proposed assistive system. The drinking task was split into eleven phases of which seven were executed by detecting EEG-based signals through the BCI. The user was asked to imagine UE motion related to the specific phase of the task to be assisted. Once detected by the BCI the phase was initiated. Each phase was then terminated when the BCI detected the volunteers clenching their teeth. RESULTS: The drinking task was completed by all five participants with an average time of 127 seconds with a standard deviation of 23 seconds. The incremental motions of elbow extension and elbow flexion were the primary limiting factors for completing this task faster. The BCI control along with the volitional motions also depended upon the users pace, hence the noticeable deviation from the average time. CONCLUSION: Through tests conducted with healthy volunteers, this study showed that our proposed system has the potential for successfully assisting individuals with neurological disorders and hemiparetic stroke to independently drink from a glass.
format Online
Article
Text
id pubmed-3983865
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39838652014-04-12 Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation Looned, Ritik Webb, Jacob Xiao, Zheng Gang Menon, Carlo J Neuroeng Rehabil Research BACKGROUND: The aim of the present study is to demonstrate, through tests with healthy volunteers, the feasibility of potentially assisting individuals with neurological disorders via a portable assistive technology for the upper extremities (UE). For this purpose the task of independently drinking a glass of water was selected, as it is one of the most basic and vital activities of the daily living that is unfortunately not achievable by individuals severely affected by stroke. METHODS: To accomplish the aim of this study we introduce a wearable and portable system consisting of a novel lightweight Robotic Arm Orthosis (RAO), a Functional Electrical Stimulation (FES) system, and a simple wireless Brain-Computer Interface (BCI). This system is able to process electroencephalographic (EEG) signals and translate them into motions of the impaired arm. Five healthy volunteers participated in this study and were asked to simulate stroke patient symptoms with no voluntary control of their hand and arm. The setup was designed such as the volitional movements of the healthy volunteers’ UE did not interfere with the evaluation of the proposed assistive system. The drinking task was split into eleven phases of which seven were executed by detecting EEG-based signals through the BCI. The user was asked to imagine UE motion related to the specific phase of the task to be assisted. Once detected by the BCI the phase was initiated. Each phase was then terminated when the BCI detected the volunteers clenching their teeth. RESULTS: The drinking task was completed by all five participants with an average time of 127 seconds with a standard deviation of 23 seconds. The incremental motions of elbow extension and elbow flexion were the primary limiting factors for completing this task faster. The BCI control along with the volitional motions also depended upon the users pace, hence the noticeable deviation from the average time. CONCLUSION: Through tests conducted with healthy volunteers, this study showed that our proposed system has the potential for successfully assisting individuals with neurological disorders and hemiparetic stroke to independently drink from a glass. BioMed Central 2014-04-07 /pmc/articles/PMC3983865/ /pubmed/24708603 http://dx.doi.org/10.1186/1743-0003-11-51 Text en Copyright © 2014 Looned et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Research
Looned, Ritik
Webb, Jacob
Xiao, Zheng Gang
Menon, Carlo
Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation
title Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation
title_full Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation
title_fullStr Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation
title_full_unstemmed Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation
title_short Assisting drinking with an affordable BCI-controlled wearable robot and electrical stimulation: a preliminary investigation
title_sort assisting drinking with an affordable bci-controlled wearable robot and electrical stimulation: a preliminary investigation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3983865/
https://www.ncbi.nlm.nih.gov/pubmed/24708603
http://dx.doi.org/10.1186/1743-0003-11-51
work_keys_str_mv AT loonedritik assistingdrinkingwithanaffordablebcicontrolledwearablerobotandelectricalstimulationapreliminaryinvestigation
AT webbjacob assistingdrinkingwithanaffordablebcicontrolledwearablerobotandelectricalstimulationapreliminaryinvestigation
AT xiaozhenggang assistingdrinkingwithanaffordablebcicontrolledwearablerobotandelectricalstimulationapreliminaryinvestigation
AT menoncarlo assistingdrinkingwithanaffordablebcicontrolledwearablerobotandelectricalstimulationapreliminaryinvestigation