Cargando…

Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials

OBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Truso...

Descripción completa

Detalles Bibliográficos
Autores principales: MACHADO, Ana Lucia, GIAMPAOLO, Eunice Teresinha, VERGANI, Carlos Eduardo, de SOUZA, Juliana Feltrin, JORGE, Janaina Habib
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3984201/
https://www.ncbi.nlm.nih.gov/pubmed/21986658
http://dx.doi.org/10.1590/S1678-77572011000500015
_version_ 1782311418779926528
author MACHADO, Ana Lucia
GIAMPAOLO, Eunice Teresinha
VERGANI, Carlos Eduardo
de SOUZA, Juliana Feltrin
JORGE, Janaina Habib
author_facet MACHADO, Ana Lucia
GIAMPAOLO, Eunice Teresinha
VERGANI, Carlos Eduardo
de SOUZA, Juliana Feltrin
JORGE, Janaina Habib
author_sort MACHADO, Ana Lucia
collection PubMed
description OBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS: Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05). RESULTS: At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P≤0.041) and New Truliner (0.19 to 0.76 µm; P≤0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05). CONCLUSIONS: The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft.
format Online
Article
Text
id pubmed-3984201
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-39842012014-04-14 Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials MACHADO, Ana Lucia GIAMPAOLO, Eunice Teresinha VERGANI, Carlos Eduardo de SOUZA, Juliana Feltrin JORGE, Janaina Habib J Appl Oral Sci Original Articles OBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS: Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05). RESULTS: At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P≤0.041) and New Truliner (0.19 to 0.76 µm; P≤0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05). CONCLUSIONS: The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2011 /pmc/articles/PMC3984201/ /pubmed/21986658 http://dx.doi.org/10.1590/S1678-77572011000500015 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
MACHADO, Ana Lucia
GIAMPAOLO, Eunice Teresinha
VERGANI, Carlos Eduardo
de SOUZA, Juliana Feltrin
JORGE, Janaina Habib
Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials
title Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials
title_full Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials
title_fullStr Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials
title_full_unstemmed Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials
title_short Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials
title_sort changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. surface roughness of denture base and reline materials
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3984201/
https://www.ncbi.nlm.nih.gov/pubmed/21986658
http://dx.doi.org/10.1590/S1678-77572011000500015
work_keys_str_mv AT machadoanalucia changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT giampaoloeuniceteresinha changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT verganicarloseduardo changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT desouzajulianafeltrin changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials
AT jorgejanainahabib changesinroughnessofdenturebaseandrelinematerialsbychemicaldisinfectionormicrowaveirradiationsurfaceroughnessofdenturebaseandrelinematerials