Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction

A validated ultrahigh-performance liquid chromatography method using 1.7 μm core–shell particles is presented for the identification and quantification of β-carotene (BC) and related cleavage products (CPs) in primary cell culture media. Besides BC, apo-4′-, apo-8′-, apo-10′-, and apo-12′-carotenals...

Descripción completa

Detalles Bibliográficos
Autores principales: Martano, G., Bojaxhi, E., Forstenlehner, I. C., Huber, C. G., Bresgen, N., Eckl, P. M., Stutz, H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3984670/
https://www.ncbi.nlm.nih.gov/pubmed/24652151
http://dx.doi.org/10.1007/s00216-014-7725-8
_version_ 1782311464405565440
author Martano, G.
Bojaxhi, E.
Forstenlehner, I. C.
Huber, C. G.
Bresgen, N.
Eckl, P. M.
Stutz, H.
author_facet Martano, G.
Bojaxhi, E.
Forstenlehner, I. C.
Huber, C. G.
Bresgen, N.
Eckl, P. M.
Stutz, H.
author_sort Martano, G.
collection PubMed
description A validated ultrahigh-performance liquid chromatography method using 1.7 μm core–shell particles is presented for the identification and quantification of β-carotene (BC) and related cleavage products (CPs) in primary cell culture media. Besides BC, apo-4′-, apo-8′-, apo-10′-, and apo-12′-carotenals, as well as 5,6-epoxy-β-carotene, were selected as target analytes. Detection was performed via an 80-Hz diode array detector and an electrospray ionization–linear quadrupole ion trap–Orbitrap XL mass spectrometer, both hyphenated in series. Total analysis time was below 6 min with peak widths <12 s. Addition of trifluoroacetic acid and tetrahydrofuran to the mobile phase allowed for the mass spectrometric detection of BC and related CPs and reduced peak tailing due to improved solubility of hydrophobic analytes. Intra-day and inter-day precision for UV and mass spectrometric detection were ≤1.5 % for retention times and ≤5.1 % for peak areas. Instrumental linearity was confirmed by Mandel’s fitting test between 0.25 (or 1.00 μg/mL) and 5.00 μg/mL for UV detection. The higher sensitivity of mass spectrometric detection allowed for the coverage of three concentration domains between 0.025 and 5.00 μg/mL in linearity testing. Homoscedasticity was confirmed between 0.10 and 5.00 μg/mL for Orbitrap XL MS. The limits of quantification were between 52.6 and 889.4 ng/mL for UV detection and between 19.3 and 102.4 ng/L for mass spectrometric detection. Offline solid-phase extraction from culture media fortified with BC and CPs provided intra- and inter-day recoveries between 65.8 and 102.4 % with coefficients of variation ≤6.2 %. Primary rat hepatocyte cultures treated with BC and subjected to different oxidative stress conditions contained 5,6-epoxy-BC and apo-4′-carotenal besides residual BC. Apparently, 5,6-epoxy-BC was formed in the medium via autoxidation of BC by ambient oxygen.
format Online
Article
Text
id pubmed-3984670
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-39846702014-04-23 Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction Martano, G. Bojaxhi, E. Forstenlehner, I. C. Huber, C. G. Bresgen, N. Eckl, P. M. Stutz, H. Anal Bioanal Chem Research Paper A validated ultrahigh-performance liquid chromatography method using 1.7 μm core–shell particles is presented for the identification and quantification of β-carotene (BC) and related cleavage products (CPs) in primary cell culture media. Besides BC, apo-4′-, apo-8′-, apo-10′-, and apo-12′-carotenals, as well as 5,6-epoxy-β-carotene, were selected as target analytes. Detection was performed via an 80-Hz diode array detector and an electrospray ionization–linear quadrupole ion trap–Orbitrap XL mass spectrometer, both hyphenated in series. Total analysis time was below 6 min with peak widths <12 s. Addition of trifluoroacetic acid and tetrahydrofuran to the mobile phase allowed for the mass spectrometric detection of BC and related CPs and reduced peak tailing due to improved solubility of hydrophobic analytes. Intra-day and inter-day precision for UV and mass spectrometric detection were ≤1.5 % for retention times and ≤5.1 % for peak areas. Instrumental linearity was confirmed by Mandel’s fitting test between 0.25 (or 1.00 μg/mL) and 5.00 μg/mL for UV detection. The higher sensitivity of mass spectrometric detection allowed for the coverage of three concentration domains between 0.025 and 5.00 μg/mL in linearity testing. Homoscedasticity was confirmed between 0.10 and 5.00 μg/mL for Orbitrap XL MS. The limits of quantification were between 52.6 and 889.4 ng/mL for UV detection and between 19.3 and 102.4 ng/L for mass spectrometric detection. Offline solid-phase extraction from culture media fortified with BC and CPs provided intra- and inter-day recoveries between 65.8 and 102.4 % with coefficients of variation ≤6.2 %. Primary rat hepatocyte cultures treated with BC and subjected to different oxidative stress conditions contained 5,6-epoxy-BC and apo-4′-carotenal besides residual BC. Apparently, 5,6-epoxy-BC was formed in the medium via autoxidation of BC by ambient oxygen. Springer Berlin Heidelberg 2014-03-21 2014 /pmc/articles/PMC3984670/ /pubmed/24652151 http://dx.doi.org/10.1007/s00216-014-7725-8 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Paper
Martano, G.
Bojaxhi, E.
Forstenlehner, I. C.
Huber, C. G.
Bresgen, N.
Eckl, P. M.
Stutz, H.
Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
title Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
title_full Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
title_fullStr Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
title_full_unstemmed Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
title_short Validation and application of sub-2 μm core–shell UHPLC–UV–ESI–Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
title_sort validation and application of sub-2 μm core–shell uhplc–uv–esi–orbitrap ms for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3984670/
https://www.ncbi.nlm.nih.gov/pubmed/24652151
http://dx.doi.org/10.1007/s00216-014-7725-8
work_keys_str_mv AT martanog validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction
AT bojaxhie validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction
AT forstenlehneric validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction
AT hubercg validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction
AT bresgenn validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction
AT ecklpm validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction
AT stutzh validationandapplicationofsub2mmcoreshelluhplcuvesiorbitrapmsforidentificationandquantificationofbcaroteneandselectedcleavageproductswithprecedingsolidphaseextraction