Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax

Objectives. To assess a human cadaver model for training emergency medicine residents in the ultrasound diagnosis of pneumothorax. Methods. Single-blinded observational study using a human cadaveric model at an academic medical center. Three lightly embalmed cadavers were used to create three “norma...

Descripción completa

Detalles Bibliográficos
Autores principales: Adhikari, Srikar, Zeger, Wesley, Wadman, Michael, Walker, Richard, Lomneth, Carol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3984816/
https://www.ncbi.nlm.nih.gov/pubmed/24790999
http://dx.doi.org/10.1155/2014/724050
_version_ 1782311496914567168
author Adhikari, Srikar
Zeger, Wesley
Wadman, Michael
Walker, Richard
Lomneth, Carol
author_facet Adhikari, Srikar
Zeger, Wesley
Wadman, Michael
Walker, Richard
Lomneth, Carol
author_sort Adhikari, Srikar
collection PubMed
description Objectives. To assess a human cadaver model for training emergency medicine residents in the ultrasound diagnosis of pneumothorax. Methods. Single-blinded observational study using a human cadaveric model at an academic medical center. Three lightly embalmed cadavers were used to create three “normal lungs” and three lungs modeling a “pneumothorax.” The residents were blinded to the side and number of pneumothoraces, as well as to each other's findings. Each resident performed an ultrasound examination on all six lung models during ventilation of cadavers. They were evaluated on their ability to identify the presence or absence of the sliding-lung sign and seashore sign. Results. A total of 84 ultrasound examinations (42-“normal lung,” 42-“pneumothorax”) were performed. A sliding-lung sign was accurately identified in 39 scans, and the seashore sign was accurately identified in 34 scans. The sensitivity and specificity for the sliding-lung sign were 93% (95% CI, 85–100%) and 90% (95% CI, 81–99%), respectively. The sensitivity and specificity for the seashore sign were 80% (95% CI, 68–92%) and 83% (95% CI, 72–94%), respectively. Conclusions. Lightly embalmed human cadavers may provide an excellent model for mimicking the sonographic appearance of pneumothorax.
format Online
Article
Text
id pubmed-3984816
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-39848162014-04-30 Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax Adhikari, Srikar Zeger, Wesley Wadman, Michael Walker, Richard Lomneth, Carol Biomed Res Int Research Article Objectives. To assess a human cadaver model for training emergency medicine residents in the ultrasound diagnosis of pneumothorax. Methods. Single-blinded observational study using a human cadaveric model at an academic medical center. Three lightly embalmed cadavers were used to create three “normal lungs” and three lungs modeling a “pneumothorax.” The residents were blinded to the side and number of pneumothoraces, as well as to each other's findings. Each resident performed an ultrasound examination on all six lung models during ventilation of cadavers. They were evaluated on their ability to identify the presence or absence of the sliding-lung sign and seashore sign. Results. A total of 84 ultrasound examinations (42-“normal lung,” 42-“pneumothorax”) were performed. A sliding-lung sign was accurately identified in 39 scans, and the seashore sign was accurately identified in 34 scans. The sensitivity and specificity for the sliding-lung sign were 93% (95% CI, 85–100%) and 90% (95% CI, 81–99%), respectively. The sensitivity and specificity for the seashore sign were 80% (95% CI, 68–92%) and 83% (95% CI, 72–94%), respectively. Conclusions. Lightly embalmed human cadavers may provide an excellent model for mimicking the sonographic appearance of pneumothorax. Hindawi Publishing Corporation 2014 2014-03-25 /pmc/articles/PMC3984816/ /pubmed/24790999 http://dx.doi.org/10.1155/2014/724050 Text en Copyright © 2014 Srikar Adhikari et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Adhikari, Srikar
Zeger, Wesley
Wadman, Michael
Walker, Richard
Lomneth, Carol
Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax
title Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax
title_full Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax
title_fullStr Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax
title_full_unstemmed Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax
title_short Assessment of a Human Cadaver Model for Training Emergency Medicine Residents in the Ultrasound Diagnosis of Pneumothorax
title_sort assessment of a human cadaver model for training emergency medicine residents in the ultrasound diagnosis of pneumothorax
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3984816/
https://www.ncbi.nlm.nih.gov/pubmed/24790999
http://dx.doi.org/10.1155/2014/724050
work_keys_str_mv AT adhikarisrikar assessmentofahumancadavermodelfortrainingemergencymedicineresidentsintheultrasounddiagnosisofpneumothorax
AT zegerwesley assessmentofahumancadavermodelfortrainingemergencymedicineresidentsintheultrasounddiagnosisofpneumothorax
AT wadmanmichael assessmentofahumancadavermodelfortrainingemergencymedicineresidentsintheultrasounddiagnosisofpneumothorax
AT walkerrichard assessmentofahumancadavermodelfortrainingemergencymedicineresidentsintheultrasounddiagnosisofpneumothorax
AT lomnethcarol assessmentofahumancadavermodelfortrainingemergencymedicineresidentsintheultrasounddiagnosisofpneumothorax