Cargando…
Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression
The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated. Two IOLs of 6 mm and 7 mm optic diameter were implanted. The intraocular pressure (IOP) was monitored during scleral depression by...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3985197/ https://www.ncbi.nlm.nih.gov/pubmed/24795886 http://dx.doi.org/10.1155/2014/586060 |
_version_ | 1782311539397623808 |
---|---|
author | Terauchi, Gaku Matsumoto, Celso Soiti Shinoda, Kei Matsumoto, Harue Mizota, Atsushi |
author_facet | Terauchi, Gaku Matsumoto, Celso Soiti Shinoda, Kei Matsumoto, Harue Mizota, Atsushi |
author_sort | Terauchi, Gaku |
collection | PubMed |
description | The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated. Two IOLs of 6 mm and 7 mm optic diameter were implanted. The intraocular pressure (IOP) was monitored during scleral depression by a transducer placed in the midvitreous through a sclerotomy at 6 o'clock. The area under the curve (AUC) of the IOP changes from the beginning of the indentation to the point when the peripheral retinal surface was observed through the IOL optics was measured. The AUC was significantly larger in eyes with a 6 mm IOL than in eyes with a 7 mm IOL (p < 0.05). The IOP elevation at the endpoint was higher in eyes with the 6 mm IOL than in eyes with the 7 mm IOL. We conclude that the AUC may represent the degree of stress induced by scleral depression. The higher AUC value with the X-60 may be because of the longer distance from the peripheral retina to the edge of the IOL optics. |
format | Online Article Text |
id | pubmed-3985197 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-39851972014-05-04 Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression Terauchi, Gaku Matsumoto, Celso Soiti Shinoda, Kei Matsumoto, Harue Mizota, Atsushi Biomed Res Int Research Article The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated. Two IOLs of 6 mm and 7 mm optic diameter were implanted. The intraocular pressure (IOP) was monitored during scleral depression by a transducer placed in the midvitreous through a sclerotomy at 6 o'clock. The area under the curve (AUC) of the IOP changes from the beginning of the indentation to the point when the peripheral retinal surface was observed through the IOL optics was measured. The AUC was significantly larger in eyes with a 6 mm IOL than in eyes with a 7 mm IOL (p < 0.05). The IOP elevation at the endpoint was higher in eyes with the 6 mm IOL than in eyes with the 7 mm IOL. We conclude that the AUC may represent the degree of stress induced by scleral depression. The higher AUC value with the X-60 may be because of the longer distance from the peripheral retina to the edge of the IOL optics. Hindawi Publishing Corporation 2014 2014-03-27 /pmc/articles/PMC3985197/ /pubmed/24795886 http://dx.doi.org/10.1155/2014/586060 Text en Copyright © 2014 Gaku Terauchi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Terauchi, Gaku Matsumoto, Celso Soiti Shinoda, Kei Matsumoto, Harue Mizota, Atsushi Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression |
title | Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression |
title_full | Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression |
title_fullStr | Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression |
title_full_unstemmed | Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression |
title_short | Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression |
title_sort | effect of intraocular lens diameter implanted in enucleated porcine eye on intraocular pressure induced by scleral depression |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3985197/ https://www.ncbi.nlm.nih.gov/pubmed/24795886 http://dx.doi.org/10.1155/2014/586060 |
work_keys_str_mv | AT terauchigaku effectofintraocularlensdiameterimplantedinenucleatedporcineeyeonintraocularpressureinducedbyscleraldepression AT matsumotocelsosoiti effectofintraocularlensdiameterimplantedinenucleatedporcineeyeonintraocularpressureinducedbyscleraldepression AT shinodakei effectofintraocularlensdiameterimplantedinenucleatedporcineeyeonintraocularpressureinducedbyscleraldepression AT matsumotoharue effectofintraocularlensdiameterimplantedinenucleatedporcineeyeonintraocularpressureinducedbyscleraldepression AT mizotaatsushi effectofintraocularlensdiameterimplantedinenucleatedporcineeyeonintraocularpressureinducedbyscleraldepression |