Cargando…
Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies
A fully automated 96-well On-Line Solid Phase Extraction (SPE) followed by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometric (MS/MS) method for the determination of ABT-925 (2-{3-[4-(2-tert-Butyl-6-trifluoromethyl-pyrimidin-4-yl)-piperazin-1-yl)-propyl-sulfanyl}-3H-pyrimidin-4-...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3986714/ https://www.ncbi.nlm.nih.gov/pubmed/27721349 http://dx.doi.org/10.3390/pharmaceutics2020171 |
_version_ | 1782311760348315648 |
---|---|
author | Wan, Katty Rieser, Matthew El-Shourbagy, Tawakol |
author_facet | Wan, Katty Rieser, Matthew El-Shourbagy, Tawakol |
author_sort | Wan, Katty |
collection | PubMed |
description | A fully automated 96-well On-Line Solid Phase Extraction (SPE) followed by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometric (MS/MS) method for the determination of ABT-925 (2-{3-[4-(2-tert-Butyl-6-trifluoromethyl-pyrimidin-4-yl)-piperazin-1-yl)-propyl-sulfanyl}-3H-pyrimidin-4-one fumarate) in human plasma was developed, validated and utilized in Phase II clinical studies. 50 µL of plasma sample was fortified with internal standard (IS, d8-ABT-925) and extracted on-line with Cohesive Turbo Flow Cyclone P HTLC column. The chromatographic separation was performed on Aquasil C18 (3 μm 50 × 3 mm) HPLC column with a mobile phase consisting of 50/50/0.1 (v/v/v) ACN/H2O/formic acid. The mass spectrometric measurement was conducted under positive ion mode using multiple reaction monitoring (MRM) of m/z 457.4 → 329.4 for analyte and m/z 465.5 → 337.5 for IS. The peak area ratio (analyte/IS) was used to quantitate ABT-925. A dynamic range of 0.0102 μg/mL to 5.24 μg/mL was established after the validation. The validated method was then used for two Phase II studies. To demonstrate the method reproducibility, approximately 10% of the incurred samples from one study were repeated in singlet. The repeated values were compared to the initial values. All repeated values agreed within ±15% of the mean values. |
format | Online Article Text |
id | pubmed-3986714 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-39867142014-04-15 Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies Wan, Katty Rieser, Matthew El-Shourbagy, Tawakol Pharmaceutics Article A fully automated 96-well On-Line Solid Phase Extraction (SPE) followed by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometric (MS/MS) method for the determination of ABT-925 (2-{3-[4-(2-tert-Butyl-6-trifluoromethyl-pyrimidin-4-yl)-piperazin-1-yl)-propyl-sulfanyl}-3H-pyrimidin-4-one fumarate) in human plasma was developed, validated and utilized in Phase II clinical studies. 50 µL of plasma sample was fortified with internal standard (IS, d8-ABT-925) and extracted on-line with Cohesive Turbo Flow Cyclone P HTLC column. The chromatographic separation was performed on Aquasil C18 (3 μm 50 × 3 mm) HPLC column with a mobile phase consisting of 50/50/0.1 (v/v/v) ACN/H2O/formic acid. The mass spectrometric measurement was conducted under positive ion mode using multiple reaction monitoring (MRM) of m/z 457.4 → 329.4 for analyte and m/z 465.5 → 337.5 for IS. The peak area ratio (analyte/IS) was used to quantitate ABT-925. A dynamic range of 0.0102 μg/mL to 5.24 μg/mL was established after the validation. The validated method was then used for two Phase II studies. To demonstrate the method reproducibility, approximately 10% of the incurred samples from one study were repeated in singlet. The repeated values were compared to the initial values. All repeated values agreed within ±15% of the mean values. MDPI 2010-05-04 /pmc/articles/PMC3986714/ /pubmed/27721349 http://dx.doi.org/10.3390/pharmaceutics2020171 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. http://creativecommons.org/licenses/by/3.0/ This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Wan, Katty Rieser, Matthew El-Shourbagy, Tawakol Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies |
title | Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies |
title_full | Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies |
title_fullStr | Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies |
title_full_unstemmed | Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies |
title_short | Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies |
title_sort | quantitative determination of abt-925 in human plasma by on-line spe and lc-ms/ms: validation and sample analysis in phase ii studies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3986714/ https://www.ncbi.nlm.nih.gov/pubmed/27721349 http://dx.doi.org/10.3390/pharmaceutics2020171 |
work_keys_str_mv | AT wankatty quantitativedeterminationofabt925inhumanplasmabyonlinespeandlcmsmsvalidationandsampleanalysisinphaseiistudies AT riesermatthew quantitativedeterminationofabt925inhumanplasmabyonlinespeandlcmsmsvalidationandsampleanalysisinphaseiistudies AT elshourbagytawakol quantitativedeterminationofabt925inhumanplasmabyonlinespeandlcmsmsvalidationandsampleanalysisinphaseiistudies |