Cargando…

Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study

Although minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has widely been developed in patients with lumbar diseases, surgeons risk exposure to fluoroscopic radiation. However, to date, there is no studies quantifying the effective dose during MIS-TLIF procedure, and the radiatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Funao, Haruki, Ishii, Ken, Momoshima, Suketaka, Iwanami, Akio, Hosogane, Naobumi, Watanabe, Kota, Nakamura, Masaya, Toyama, Yoshiaki, Matsumoto, Morio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3988176/
https://www.ncbi.nlm.nih.gov/pubmed/24736321
http://dx.doi.org/10.1371/journal.pone.0095233
_version_ 1782311994598096896
author Funao, Haruki
Ishii, Ken
Momoshima, Suketaka
Iwanami, Akio
Hosogane, Naobumi
Watanabe, Kota
Nakamura, Masaya
Toyama, Yoshiaki
Matsumoto, Morio
author_facet Funao, Haruki
Ishii, Ken
Momoshima, Suketaka
Iwanami, Akio
Hosogane, Naobumi
Watanabe, Kota
Nakamura, Masaya
Toyama, Yoshiaki
Matsumoto, Morio
author_sort Funao, Haruki
collection PubMed
description Although minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has widely been developed in patients with lumbar diseases, surgeons risk exposure to fluoroscopic radiation. However, to date, there is no studies quantifying the effective dose during MIS-TLIF procedure, and the radiation dose distribution is still unclear. In this study, the surgeons' radiation doses at 5 places on the bodies were measured and the effective doses were assessed during 31 consecutive 1- to 3-level MIS-TLIF surgeries. The operating surgeon, assisting surgeon, and radiological technologist wore thermoluminescent dosimeter on the unshielded thyroid, chest, genitals, right middle finger, and on the chest beneath a lead apron. The doses at the lens and the effective doses were also calculated. Mean fluoroscopy times were 38.7, 53.1, and 58.5 seconds for 1, 2, or 3 fusion levels, respectively. The operating surgeon's mean exposures at the lens, thyroid, chest, genitals, finger, and the chest beneath the shield, respectively, were 0.07, 0.07, 0.09, 0.14, 0.32, and 0.05 mSv in 1-level MIS-TLIF; 0.07, 0.08, 0.09, 0.18, 0.34, and 0.05 mSv in 2-level; 0.08, 0.09, 0.14, 0.15, 0.36, and 0.06 mSv in 3-level; and 0.07, 0.08, 0.10, 0.15, 0.33, and 0.05 mSv in all cases. Mean dose at the operating surgeon's right finger was significantly higher than other measurements parts (P<0.001). The operating surgeon's effective doses (0.06, 0.06, and 0.07 mSv for 1, 2, and 3 fusion levels) were low, and didn't differ significantly from those of the assisting surgeon or radiological technologist. Revision MIS-TLIF was not associated with higher surgeons' radiation doses compared to primary MIS-TLIF. There were significantly higher surgeons' radiation doses in over-weight than in normal-weight patients. The surgeons' radiation exposure during MIS-TLIF was within the safe level by the International Commission on Radiological Protection's guidelines. The accumulated radiation exposure, especially to surgeon's hands, should be carefully monitored.
format Online
Article
Text
id pubmed-3988176
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-39881762014-04-21 Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study Funao, Haruki Ishii, Ken Momoshima, Suketaka Iwanami, Akio Hosogane, Naobumi Watanabe, Kota Nakamura, Masaya Toyama, Yoshiaki Matsumoto, Morio PLoS One Research Article Although minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has widely been developed in patients with lumbar diseases, surgeons risk exposure to fluoroscopic radiation. However, to date, there is no studies quantifying the effective dose during MIS-TLIF procedure, and the radiation dose distribution is still unclear. In this study, the surgeons' radiation doses at 5 places on the bodies were measured and the effective doses were assessed during 31 consecutive 1- to 3-level MIS-TLIF surgeries. The operating surgeon, assisting surgeon, and radiological technologist wore thermoluminescent dosimeter on the unshielded thyroid, chest, genitals, right middle finger, and on the chest beneath a lead apron. The doses at the lens and the effective doses were also calculated. Mean fluoroscopy times were 38.7, 53.1, and 58.5 seconds for 1, 2, or 3 fusion levels, respectively. The operating surgeon's mean exposures at the lens, thyroid, chest, genitals, finger, and the chest beneath the shield, respectively, were 0.07, 0.07, 0.09, 0.14, 0.32, and 0.05 mSv in 1-level MIS-TLIF; 0.07, 0.08, 0.09, 0.18, 0.34, and 0.05 mSv in 2-level; 0.08, 0.09, 0.14, 0.15, 0.36, and 0.06 mSv in 3-level; and 0.07, 0.08, 0.10, 0.15, 0.33, and 0.05 mSv in all cases. Mean dose at the operating surgeon's right finger was significantly higher than other measurements parts (P<0.001). The operating surgeon's effective doses (0.06, 0.06, and 0.07 mSv for 1, 2, and 3 fusion levels) were low, and didn't differ significantly from those of the assisting surgeon or radiological technologist. Revision MIS-TLIF was not associated with higher surgeons' radiation doses compared to primary MIS-TLIF. There were significantly higher surgeons' radiation doses in over-weight than in normal-weight patients. The surgeons' radiation exposure during MIS-TLIF was within the safe level by the International Commission on Radiological Protection's guidelines. The accumulated radiation exposure, especially to surgeon's hands, should be carefully monitored. Public Library of Science 2014-04-15 /pmc/articles/PMC3988176/ /pubmed/24736321 http://dx.doi.org/10.1371/journal.pone.0095233 Text en © 2014 Funao et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Funao, Haruki
Ishii, Ken
Momoshima, Suketaka
Iwanami, Akio
Hosogane, Naobumi
Watanabe, Kota
Nakamura, Masaya
Toyama, Yoshiaki
Matsumoto, Morio
Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study
title Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study
title_full Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study
title_fullStr Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study
title_full_unstemmed Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study
title_short Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study
title_sort surgeons' exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3988176/
https://www.ncbi.nlm.nih.gov/pubmed/24736321
http://dx.doi.org/10.1371/journal.pone.0095233
work_keys_str_mv AT funaoharuki surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT ishiiken surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT momoshimasuketaka surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT iwanamiakio surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT hosoganenaobumi surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT watanabekota surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT nakamuramasaya surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT toyamayoshiaki surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy
AT matsumotomorio surgeonsexposuretoradiationinsingleandmultilevelminimallyinvasivetransforaminallumbarinterbodyfusionaprospectivestudy