Cargando…

Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging

PURPOSE: Contrast enhanced multidetector computed tomography (MDCT) has been used as an alternative to coronary angiography for the assessment of coronary artery disease in the patient of the intermediate risk group. However, coronary calcium is a known limiting factor for MDCT evaluation. We invest...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jong Kwan, Kim, Jong Youn, Kwon, Hyuck Moon, Kim, Tae Hoon, Oh, Seung-Jin, Hong, Bum-Kee, Yoon, Young Won, Min, Pil-Ki, Kwon, Sung Woo, Lee, Byoung Kwon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3990095/
https://www.ncbi.nlm.nih.gov/pubmed/24719125
http://dx.doi.org/10.3349/ymj.2014.55.3.599
_version_ 1782312226889138176
author Park, Jong Kwan
Kim, Jong Youn
Kwon, Hyuck Moon
Kim, Tae Hoon
Oh, Seung-Jin
Hong, Bum-Kee
Yoon, Young Won
Min, Pil-Ki
Kwon, Sung Woo
Lee, Byoung Kwon
author_facet Park, Jong Kwan
Kim, Jong Youn
Kwon, Hyuck Moon
Kim, Tae Hoon
Oh, Seung-Jin
Hong, Bum-Kee
Yoon, Young Won
Min, Pil-Ki
Kwon, Sung Woo
Lee, Byoung Kwon
author_sort Park, Jong Kwan
collection PubMed
description PURPOSE: Contrast enhanced multidetector computed tomography (MDCT) has been used as an alternative to coronary angiography for the assessment of coronary artery disease in the patient of the intermediate risk group. However, coronary calcium is a known limiting factor for MDCT evaluation. We investigated the diagnostic accuracy of 64-channel MDCT with each coronary artery calcium score (CACS) by compared with intravascular ultrasound (IVUS) imaging. MATERIALS AND METHODS: A total of 54 symptomatic patients with intermediate-risk (10 females, mean age 59.9±6.9 years, Framingham point scores 9-20) with 162 sites who had a culprit lesion on 64-channel MDCT before performing coronary angiography with IVUS were enrolled. Patients were divided into 4 subgroups depending on CACS: 0, 1-99, 100-399, and >400. Lesion length, external elastic membrane (EEM) cross sectional area (CSA), minimal luminal area, and plaque area were measured and compared between IVUS and MDCT. RESULTS: The correlation coefficients for the measurements of the EEM CSA, lumen CSA, and plaque area were r=0.514, r=0.837, and r=0.578, respectively. Furthermore, there were close correlation of plaque area between four subgroups of CACS (r=0.671, r=0.623, r=0.562, r=0.571, respectively). CONCLUSION: Despite the increase in CACS, the geometric analysis of coronary arteries using with 64-channel MDCT was comparable with IVUS in symptomatic patient of the intermediate risk group.
format Online
Article
Text
id pubmed-3990095
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-39900952014-05-01 Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging Park, Jong Kwan Kim, Jong Youn Kwon, Hyuck Moon Kim, Tae Hoon Oh, Seung-Jin Hong, Bum-Kee Yoon, Young Won Min, Pil-Ki Kwon, Sung Woo Lee, Byoung Kwon Yonsei Med J Original Article PURPOSE: Contrast enhanced multidetector computed tomography (MDCT) has been used as an alternative to coronary angiography for the assessment of coronary artery disease in the patient of the intermediate risk group. However, coronary calcium is a known limiting factor for MDCT evaluation. We investigated the diagnostic accuracy of 64-channel MDCT with each coronary artery calcium score (CACS) by compared with intravascular ultrasound (IVUS) imaging. MATERIALS AND METHODS: A total of 54 symptomatic patients with intermediate-risk (10 females, mean age 59.9±6.9 years, Framingham point scores 9-20) with 162 sites who had a culprit lesion on 64-channel MDCT before performing coronary angiography with IVUS were enrolled. Patients were divided into 4 subgroups depending on CACS: 0, 1-99, 100-399, and >400. Lesion length, external elastic membrane (EEM) cross sectional area (CSA), minimal luminal area, and plaque area were measured and compared between IVUS and MDCT. RESULTS: The correlation coefficients for the measurements of the EEM CSA, lumen CSA, and plaque area were r=0.514, r=0.837, and r=0.578, respectively. Furthermore, there were close correlation of plaque area between four subgroups of CACS (r=0.671, r=0.623, r=0.562, r=0.571, respectively). CONCLUSION: Despite the increase in CACS, the geometric analysis of coronary arteries using with 64-channel MDCT was comparable with IVUS in symptomatic patient of the intermediate risk group. Yonsei University College of Medicine 2014-05-01 2014-04-01 /pmc/articles/PMC3990095/ /pubmed/24719125 http://dx.doi.org/10.3349/ymj.2014.55.3.599 Text en © Copyright: Yonsei University College of Medicine 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, Jong Kwan
Kim, Jong Youn
Kwon, Hyuck Moon
Kim, Tae Hoon
Oh, Seung-Jin
Hong, Bum-Kee
Yoon, Young Won
Min, Pil-Ki
Kwon, Sung Woo
Lee, Byoung Kwon
Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging
title Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging
title_full Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging
title_fullStr Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging
title_full_unstemmed Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging
title_short Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging
title_sort multidetector computed tomography for the evaluation of coronary artery disease; the diagnostic accuracy in calcified coronary arteries, comparing with ivus imaging
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3990095/
https://www.ncbi.nlm.nih.gov/pubmed/24719125
http://dx.doi.org/10.3349/ymj.2014.55.3.599
work_keys_str_mv AT parkjongkwan multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT kimjongyoun multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT kwonhyuckmoon multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT kimtaehoon multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT ohseungjin multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT hongbumkee multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT yoonyoungwon multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT minpilki multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT kwonsungwoo multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging
AT leebyoungkwon multidetectorcomputedtomographyfortheevaluationofcoronaryarterydiseasethediagnosticaccuracyincalcifiedcoronaryarteriescomparingwithivusimaging