Cargando…
A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives
Reproductive health has been deleteriously affected by poor quality medicines. Emergency contraceptive pills (ECPs) are an important birth control method that women can use after unprotected coitus for reducing the risk of pregnancy. In response to the detection of poor quality ECPs commercially ava...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3991657/ https://www.ncbi.nlm.nih.gov/pubmed/24748219 http://dx.doi.org/10.1371/journal.pone.0095353 |
_version_ | 1782312478485512192 |
---|---|
author | Monge, María Eugenia Dwivedi, Prabha Zhou, Manshui Payne, Michael Harris, Chris House, Blaine Juggins, Yvonne Cizmarik, Peter Newton, Paul N. Fernández, Facundo M. Jenkins, David |
author_facet | Monge, María Eugenia Dwivedi, Prabha Zhou, Manshui Payne, Michael Harris, Chris House, Blaine Juggins, Yvonne Cizmarik, Peter Newton, Paul N. Fernández, Facundo M. Jenkins, David |
author_sort | Monge, María Eugenia |
collection | PubMed |
description | Reproductive health has been deleteriously affected by poor quality medicines. Emergency contraceptive pills (ECPs) are an important birth control method that women can use after unprotected coitus for reducing the risk of pregnancy. In response to the detection of poor quality ECPs commercially available in the Peruvian market we developed a tiered multi-platform analytical strategy. In a survey to assess ECP medicine quality in Peru, 7 out of 25 different batches showed inadequate release of levonorgestrel by dissolution testing or improper amounts of active ingredient. One batch was found to contain a wrong active ingredient, with no detectable levonorgestrel. By combining ultrahigh performance liquid chromatography-ion mobility spectrometry-mass spectrometry (UHPLC-IMS-MS) and direct analysis in real time MS (DART-MS) the unknown compound was identified as the antibiotic sulfamethoxazole. Quantitation by UHPLC-triple quadrupole tandem MS (QqQ-MS/MS) indicated that the wrong ingredient was present in the ECP sample at levels which could have significant physiological effects. Further chemical characterization of the poor quality ECP samples included the identification of the excipients by 2D Diffusion-Ordered Nuclear Magnetic Resonance Spectroscopy (DOSY (1)H NMR) indicating the presence of lactose and magnesium stearate. |
format | Online Article Text |
id | pubmed-3991657 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39916572014-04-21 A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives Monge, María Eugenia Dwivedi, Prabha Zhou, Manshui Payne, Michael Harris, Chris House, Blaine Juggins, Yvonne Cizmarik, Peter Newton, Paul N. Fernández, Facundo M. Jenkins, David PLoS One Research Article Reproductive health has been deleteriously affected by poor quality medicines. Emergency contraceptive pills (ECPs) are an important birth control method that women can use after unprotected coitus for reducing the risk of pregnancy. In response to the detection of poor quality ECPs commercially available in the Peruvian market we developed a tiered multi-platform analytical strategy. In a survey to assess ECP medicine quality in Peru, 7 out of 25 different batches showed inadequate release of levonorgestrel by dissolution testing or improper amounts of active ingredient. One batch was found to contain a wrong active ingredient, with no detectable levonorgestrel. By combining ultrahigh performance liquid chromatography-ion mobility spectrometry-mass spectrometry (UHPLC-IMS-MS) and direct analysis in real time MS (DART-MS) the unknown compound was identified as the antibiotic sulfamethoxazole. Quantitation by UHPLC-triple quadrupole tandem MS (QqQ-MS/MS) indicated that the wrong ingredient was present in the ECP sample at levels which could have significant physiological effects. Further chemical characterization of the poor quality ECP samples included the identification of the excipients by 2D Diffusion-Ordered Nuclear Magnetic Resonance Spectroscopy (DOSY (1)H NMR) indicating the presence of lactose and magnesium stearate. Public Library of Science 2014-04-18 /pmc/articles/PMC3991657/ /pubmed/24748219 http://dx.doi.org/10.1371/journal.pone.0095353 Text en © 2014 Monge et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Monge, María Eugenia Dwivedi, Prabha Zhou, Manshui Payne, Michael Harris, Chris House, Blaine Juggins, Yvonne Cizmarik, Peter Newton, Paul N. Fernández, Facundo M. Jenkins, David A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives |
title | A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives |
title_full | A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives |
title_fullStr | A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives |
title_full_unstemmed | A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives |
title_short | A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives |
title_sort | tiered analytical approach for investigating poor quality emergency contraceptives |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3991657/ https://www.ncbi.nlm.nih.gov/pubmed/24748219 http://dx.doi.org/10.1371/journal.pone.0095353 |
work_keys_str_mv | AT mongemariaeugenia atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT dwivediprabha atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT zhoumanshui atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT paynemichael atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT harrischris atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT houseblaine atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT jugginsyvonne atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT cizmarikpeter atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT newtonpauln atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT fernandezfacundom atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT jenkinsdavid atieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT mongemariaeugenia tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT dwivediprabha tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT zhoumanshui tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT paynemichael tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT harrischris tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT houseblaine tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT jugginsyvonne tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT cizmarikpeter tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT newtonpauln tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT fernandezfacundom tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives AT jenkinsdavid tieredanalyticalapproachforinvestigatingpoorqualityemergencycontraceptives |