A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom

BACKGROUND: Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. OBJECTIVE: We precisely compared high-resolution k-t SENSE MR cardiac perfusion...

Descripción completa

Detalles Bibliográficos
Autores principales: Otton, James, Morton, Geraint, Schuster, Andreas, Bigalke, Boris, Marano, Riccardo, Olivotti, Luca, Nagel, Eike, Chiribiri, Amedeo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994525/
https://www.ncbi.nlm.nih.gov/pubmed/23622506
http://dx.doi.org/10.1016/j.jcct.2013.01.016
_version_ 1782312744238710784
author Otton, James
Morton, Geraint
Schuster, Andreas
Bigalke, Boris
Marano, Riccardo
Olivotti, Luca
Nagel, Eike
Chiribiri, Amedeo
author_facet Otton, James
Morton, Geraint
Schuster, Andreas
Bigalke, Boris
Marano, Riccardo
Olivotti, Luca
Nagel, Eike
Chiribiri, Amedeo
author_sort Otton, James
collection PubMed
description BACKGROUND: Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. OBJECTIVE: We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. METHODS: We used a customized MR imaging and CT compatible dynamic myocardial perfusion phantom to represent the human circulation. CT perfusion studies were performed with a Philips iCT (256 slice) CT, with isotropic resolution of 0.6 mm(3). MR perfusion was performed with k-t SENSE acceleration at 3 T and spatial resolution of 1.2 × 1.2 × 10 mm. The image contrast between normal and underperfused myocardial compartments was quantified at various perfusion and photon energy settings. Noise estimates were based on published clinical data. RESULTS: Contrast by CTP highly depends on photon energy and also timing of imaging within the myocardial perfusion upslope. For an identical myocardial perfusion deficit, the native image contrast-to-noise ratio (CNR) generated by CT and MR are similar. If slice averaging is used, the CNR of a perfusion deficit is expected to be greater for CTP than MR perfusion (MRP). Perfect timing during single time point CTP imaging is difficult to achieve, and CNR by CT decreases by 24%–31% two seconds from the optimal imaging time point. Although single-phase CT perfusion offers higher spatial resolution, MRP allows multiple time point sampling and quantitative analysis. CONCLUSION: The ability of CTP and current optimal MRP techniques to detect simulated myocardial perfusion deficits is similar.
format Online
Article
Text
id pubmed-3994525
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-39945252014-04-24 A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom Otton, James Morton, Geraint Schuster, Andreas Bigalke, Boris Marano, Riccardo Olivotti, Luca Nagel, Eike Chiribiri, Amedeo J Cardiovasc Comput Tomogr Original Research Article BACKGROUND: Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. OBJECTIVE: We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. METHODS: We used a customized MR imaging and CT compatible dynamic myocardial perfusion phantom to represent the human circulation. CT perfusion studies were performed with a Philips iCT (256 slice) CT, with isotropic resolution of 0.6 mm(3). MR perfusion was performed with k-t SENSE acceleration at 3 T and spatial resolution of 1.2 × 1.2 × 10 mm. The image contrast between normal and underperfused myocardial compartments was quantified at various perfusion and photon energy settings. Noise estimates were based on published clinical data. RESULTS: Contrast by CTP highly depends on photon energy and also timing of imaging within the myocardial perfusion upslope. For an identical myocardial perfusion deficit, the native image contrast-to-noise ratio (CNR) generated by CT and MR are similar. If slice averaging is used, the CNR of a perfusion deficit is expected to be greater for CTP than MR perfusion (MRP). Perfect timing during single time point CTP imaging is difficult to achieve, and CNR by CT decreases by 24%–31% two seconds from the optimal imaging time point. Although single-phase CT perfusion offers higher spatial resolution, MRP allows multiple time point sampling and quantitative analysis. CONCLUSION: The ability of CTP and current optimal MRP techniques to detect simulated myocardial perfusion deficits is similar. Elsevier 2013-03 /pmc/articles/PMC3994525/ /pubmed/23622506 http://dx.doi.org/10.1016/j.jcct.2013.01.016 Text en Crown Copyright © 2013 Published by Elsevier Inc. on behalf of Society for Cardiovascular Computed Tomography. All rights reserved. https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/) , which allows reusers to distribute, remix, adapt, and build upon the material in any medium or format, so long as attribution is given to the creator. The license allows for commercial use.
spellingShingle Original Research Article
Otton, James
Morton, Geraint
Schuster, Andreas
Bigalke, Boris
Marano, Riccardo
Olivotti, Luca
Nagel, Eike
Chiribiri, Amedeo
A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
title A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
title_full A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
title_fullStr A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
title_full_unstemmed A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
title_short A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
title_sort direct comparison of the sensitivity of ct and mr cardiac perfusion using a myocardial perfusion phantom
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994525/
https://www.ncbi.nlm.nih.gov/pubmed/23622506
http://dx.doi.org/10.1016/j.jcct.2013.01.016
work_keys_str_mv AT ottonjames adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT mortongeraint adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT schusterandreas adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT bigalkeboris adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT maranoriccardo adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT olivottiluca adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT nageleike adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT chiribiriamedeo adirectcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT ottonjames directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT mortongeraint directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT schusterandreas directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT bigalkeboris directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT maranoriccardo directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT olivottiluca directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT nageleike directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom
AT chiribiriamedeo directcomparisonofthesensitivityofctandmrcardiacperfusionusingamyocardialperfusionphantom