Cargando…
A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
BACKGROUND: To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. METHODS: Fifteen breast cancer patients after breast-conserving surgery (BCS) were rec...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994573/ https://www.ncbi.nlm.nih.gov/pubmed/24646022 http://dx.doi.org/10.1186/1748-717X-9-76 |
_version_ | 1782312751408873472 |
---|---|
author | Ding, Yun Li, Jianbin Wang, Wei Wang, Suzhen Wang, Jinzhi Ma, Zhifang Shao, Qian Xu, Min |
author_facet | Ding, Yun Li, Jianbin Wang, Wei Wang, Suzhen Wang, Jinzhi Ma, Zhifang Shao, Qian Xu, Min |
author_sort | Ding, Yun |
collection | PubMed |
description | BACKGROUND: To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. METHODS: Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. RESULTS: The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). CONCLUSIONS: There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV. |
format | Online Article Text |
id | pubmed-3994573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-39945732014-05-07 A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery Ding, Yun Li, Jianbin Wang, Wei Wang, Suzhen Wang, Jinzhi Ma, Zhifang Shao, Qian Xu, Min Radiat Oncol Research BACKGROUND: To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. METHODS: Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. RESULTS: The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). CONCLUSIONS: There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV. BioMed Central 2014-03-19 /pmc/articles/PMC3994573/ /pubmed/24646022 http://dx.doi.org/10.1186/1748-717X-9-76 Text en Copyright © 2014 Ding et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Ding, Yun Li, Jianbin Wang, Wei Wang, Suzhen Wang, Jinzhi Ma, Zhifang Shao, Qian Xu, Min A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery |
title | A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery |
title_full | A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery |
title_fullStr | A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery |
title_full_unstemmed | A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery |
title_short | A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery |
title_sort | comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4dct scan for external-beam partial breast irradiation after breast conserving surgery |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994573/ https://www.ncbi.nlm.nih.gov/pubmed/24646022 http://dx.doi.org/10.1186/1748-717X-9-76 |
work_keys_str_mv | AT dingyun acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT lijianbin acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT wangwei acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT wangsuzhen acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT wangjinzhi acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT mazhifang acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT shaoqian acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT xumin acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT dingyun comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT lijianbin comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT wangwei comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT wangsuzhen comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT wangjinzhi comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT mazhifang comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT shaoqian comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery AT xumin comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery |