Cargando…

A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery

BACKGROUND: To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. METHODS: Fifteen breast cancer patients after breast-conserving surgery (BCS) were rec...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Yun, Li, Jianbin, Wang, Wei, Wang, Suzhen, Wang, Jinzhi, Ma, Zhifang, Shao, Qian, Xu, Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994573/
https://www.ncbi.nlm.nih.gov/pubmed/24646022
http://dx.doi.org/10.1186/1748-717X-9-76
_version_ 1782312751408873472
author Ding, Yun
Li, Jianbin
Wang, Wei
Wang, Suzhen
Wang, Jinzhi
Ma, Zhifang
Shao, Qian
Xu, Min
author_facet Ding, Yun
Li, Jianbin
Wang, Wei
Wang, Suzhen
Wang, Jinzhi
Ma, Zhifang
Shao, Qian
Xu, Min
author_sort Ding, Yun
collection PubMed
description BACKGROUND: To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. METHODS: Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. RESULTS: The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). CONCLUSIONS: There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV.
format Online
Article
Text
id pubmed-3994573
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39945732014-05-07 A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery Ding, Yun Li, Jianbin Wang, Wei Wang, Suzhen Wang, Jinzhi Ma, Zhifang Shao, Qian Xu, Min Radiat Oncol Research BACKGROUND: To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. METHODS: Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. RESULTS: The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). CONCLUSIONS: There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV. BioMed Central 2014-03-19 /pmc/articles/PMC3994573/ /pubmed/24646022 http://dx.doi.org/10.1186/1748-717X-9-76 Text en Copyright © 2014 Ding et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ding, Yun
Li, Jianbin
Wang, Wei
Wang, Suzhen
Wang, Jinzhi
Ma, Zhifang
Shao, Qian
Xu, Min
A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
title A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
title_full A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
title_fullStr A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
title_full_unstemmed A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
title_short A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery
title_sort comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4dct scan for external-beam partial breast irradiation after breast conserving surgery
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994573/
https://www.ncbi.nlm.nih.gov/pubmed/24646022
http://dx.doi.org/10.1186/1748-717X-9-76
work_keys_str_mv AT dingyun acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT lijianbin acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT wangwei acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT wangsuzhen acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT wangjinzhi acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT mazhifang acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT shaoqian acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT xumin acomparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT dingyun comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT lijianbin comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT wangwei comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT wangsuzhen comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT wangjinzhi comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT mazhifang comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT shaoqian comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery
AT xumin comparativestudyonthevolumeandlocalizationoftheinternalgrosstargetvolumedefinedusingtheseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiationafterbreastconservingsurgery