Cargando…

COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE

The purpose of the present study was to compare oscillation of skin blood flow with that of deoxygenation in muscle during light exercise in order to determine the physiological significance of oscillations in deoxygenation. Prolonged exercise with 50% of peak oxygen uptake was performed for 60 min....

Descripción completa

Detalles Bibliográficos
Autores principales: Yano, T., Lian, C-S., Afroundeh, R., Shirakawa, K., Yunoki, T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Institute of Sport in Warsaw 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994580/
https://www.ncbi.nlm.nih.gov/pubmed/25187674
http://dx.doi.org/10.5604/20831862.1083274
_version_ 1782312753029971968
author Yano, T.
Lian, C-S.
Afroundeh, R.
Shirakawa, K.
Yunoki, T.
author_facet Yano, T.
Lian, C-S.
Afroundeh, R.
Shirakawa, K.
Yunoki, T.
author_sort Yano, T.
collection PubMed
description The purpose of the present study was to compare oscillation of skin blood flow with that of deoxygenation in muscle during light exercise in order to determine the physiological significance of oscillations in deoxygenation. Prolonged exercise with 50% of peak oxygen uptake was performed for 60 min. Skin blood flow (SBF) was measured using a laser blood flow meter on the right vastus lateralis muscle. Deoxygenated haemoglobin/myoglobin (DHb/Mb) concentration in the left vastus lateralis were measured using a near-infrared spectroscopy system. SBF and DHb/Mb during exercise were analysed by fast Fourier transform. We classified frequency bands according to previous studies (Kvernmo et al. 1999, Kvandal et al. 2006) into phase I (0.005-0.0095 and 0.0095-0.02 Hz), phase II (0.02-0.06 Hz: phase II) and phase III (0.06-0.16 Hz). The first peak of power spectra density (PSD) in SBF appeared at 0.0078 Hz in phase I. The second peak of PSD in SBF appeared at 0.035 Hz. The third peak of PSD in SBF appeared at 0.078 Hz. The first peak of PSD in DHb/Mb appeared at 0.0039 Hz, which was out of phase I. The second peak of PSD in DHb/Mb appeared at 0.016 Hz. The third peak of PSD in DHb/Mb appeared at 0.035 Hz. The coefficient of cross correlation was very low. Cross power spectra density showed peaks of 0.0039, 0.016 and 0.035 Hz. It is concluded that a peak of 0.016 Hz in oscillations of DHb/Mb observed in muscle during exercise is associated with endothelium-dependent vasodilation (phase I) and that a peak of 0.035 Hz in DHb/Mb is associated with sympathetic nerve activity (phase II). It is also confirmed that each peak of SBF oscillations is observed in each phase.
format Online
Article
Text
id pubmed-3994580
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Institute of Sport in Warsaw
record_format MEDLINE/PubMed
spelling pubmed-39945802014-09-03 COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE Yano, T. Lian, C-S. Afroundeh, R. Shirakawa, K. Yunoki, T. Biol Sport Original Article The purpose of the present study was to compare oscillation of skin blood flow with that of deoxygenation in muscle during light exercise in order to determine the physiological significance of oscillations in deoxygenation. Prolonged exercise with 50% of peak oxygen uptake was performed for 60 min. Skin blood flow (SBF) was measured using a laser blood flow meter on the right vastus lateralis muscle. Deoxygenated haemoglobin/myoglobin (DHb/Mb) concentration in the left vastus lateralis were measured using a near-infrared spectroscopy system. SBF and DHb/Mb during exercise were analysed by fast Fourier transform. We classified frequency bands according to previous studies (Kvernmo et al. 1999, Kvandal et al. 2006) into phase I (0.005-0.0095 and 0.0095-0.02 Hz), phase II (0.02-0.06 Hz: phase II) and phase III (0.06-0.16 Hz). The first peak of power spectra density (PSD) in SBF appeared at 0.0078 Hz in phase I. The second peak of PSD in SBF appeared at 0.035 Hz. The third peak of PSD in SBF appeared at 0.078 Hz. The first peak of PSD in DHb/Mb appeared at 0.0039 Hz, which was out of phase I. The second peak of PSD in DHb/Mb appeared at 0.016 Hz. The third peak of PSD in DHb/Mb appeared at 0.035 Hz. The coefficient of cross correlation was very low. Cross power spectra density showed peaks of 0.0039, 0.016 and 0.035 Hz. It is concluded that a peak of 0.016 Hz in oscillations of DHb/Mb observed in muscle during exercise is associated with endothelium-dependent vasodilation (phase I) and that a peak of 0.035 Hz in DHb/Mb is associated with sympathetic nerve activity (phase II). It is also confirmed that each peak of SBF oscillations is observed in each phase. Institute of Sport in Warsaw 2014-01-22 2014-03 /pmc/articles/PMC3994580/ /pubmed/25187674 http://dx.doi.org/10.5604/20831862.1083274 Text en Copyright © Biology of Sport 2014 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yano, T.
Lian, C-S.
Afroundeh, R.
Shirakawa, K.
Yunoki, T.
COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE
title COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE
title_full COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE
title_fullStr COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE
title_full_unstemmed COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE
title_short COMPARISON OF OSCILLATIONS OF SKIN BLOOD FLOW AND DEOXYGENATION IN VASTUS LATERALIS IN LIGHT EXERCISE
title_sort comparison of oscillations of skin blood flow and deoxygenation in vastus lateralis in light exercise
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994580/
https://www.ncbi.nlm.nih.gov/pubmed/25187674
http://dx.doi.org/10.5604/20831862.1083274
work_keys_str_mv AT yanot comparisonofoscillationsofskinbloodflowanddeoxygenationinvastuslateralisinlightexercise
AT liancs comparisonofoscillationsofskinbloodflowanddeoxygenationinvastuslateralisinlightexercise
AT afroundehr comparisonofoscillationsofskinbloodflowanddeoxygenationinvastuslateralisinlightexercise
AT shirakawak comparisonofoscillationsofskinbloodflowanddeoxygenationinvastuslateralisinlightexercise
AT yunokit comparisonofoscillationsofskinbloodflowanddeoxygenationinvastuslateralisinlightexercise