Cargando…
Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions
OBJECTIVE: To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients. METHOD: This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant ce...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3995709/ https://www.ncbi.nlm.nih.gov/pubmed/24755864 http://dx.doi.org/10.1371/journal.pone.0095542 |
_version_ | 1782312920527405056 |
---|---|
author | Buechner, Andreas Dyballa, Karl-Heinz Hehrmann, Phillipp Fredelake, Stefan Lenarz, Thomas |
author_facet | Buechner, Andreas Dyballa, Karl-Heinz Hehrmann, Phillipp Fredelake, Stefan Lenarz, Thomas |
author_sort | Buechner, Andreas |
collection | PubMed |
description | OBJECTIVE: To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients. METHOD: This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant centre. Twelve experienced users of an Advanced Bionics HiRes90K or CII implant with a Harmony speech processor were enrolled. The cochlear implant processor of each subject was connected to one of two bilaterally placed state-of-the-art hearing aids (Phonak Ambra) providing three alternative directional processing options: an omnidirectional setting, an adaptive monaural beamformer, and a binaural beamformer. A further noise reduction algorithm (ClearVoice) was applied to the signal on the cochlear implant processor itself. The speech signal was presented from 0° and speech shaped noise presented from loudspeakers placed at ±70°, ±135° and 180°. The Oldenburg sentence test was used to determine the signal-to-noise ratio at which subjects scored 50% correct. RESULTS: Both the adaptive and binaural beamformer were significantly better than the omnidirectional condition (5.3 dB±1.2 dB and 7.1 dB±1.6 dB (p<0.001) respectively). The best score was achieved with the binaural beamformer in combination with the ClearVoice noise reduction algorithm, with a significant improvement in SRT of 7.9 dB±2.4 dB (p<0.001) over the omnidirectional alone condition. CONCLUSIONS: The study showed that the binaural beamformer implemented in the Phonak Ambra hearing aid could be used in conjunction with a Harmony speech processor to produce substantial average improvements in SRT of 7.1 dB. The monaural, adaptive beamformer provided an averaged SRT improvement of 5.3 dB. |
format | Online Article Text |
id | pubmed-3995709 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39957092014-04-25 Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions Buechner, Andreas Dyballa, Karl-Heinz Hehrmann, Phillipp Fredelake, Stefan Lenarz, Thomas PLoS One Research Article OBJECTIVE: To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients. METHOD: This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant centre. Twelve experienced users of an Advanced Bionics HiRes90K or CII implant with a Harmony speech processor were enrolled. The cochlear implant processor of each subject was connected to one of two bilaterally placed state-of-the-art hearing aids (Phonak Ambra) providing three alternative directional processing options: an omnidirectional setting, an adaptive monaural beamformer, and a binaural beamformer. A further noise reduction algorithm (ClearVoice) was applied to the signal on the cochlear implant processor itself. The speech signal was presented from 0° and speech shaped noise presented from loudspeakers placed at ±70°, ±135° and 180°. The Oldenburg sentence test was used to determine the signal-to-noise ratio at which subjects scored 50% correct. RESULTS: Both the adaptive and binaural beamformer were significantly better than the omnidirectional condition (5.3 dB±1.2 dB and 7.1 dB±1.6 dB (p<0.001) respectively). The best score was achieved with the binaural beamformer in combination with the ClearVoice noise reduction algorithm, with a significant improvement in SRT of 7.9 dB±2.4 dB (p<0.001) over the omnidirectional alone condition. CONCLUSIONS: The study showed that the binaural beamformer implemented in the Phonak Ambra hearing aid could be used in conjunction with a Harmony speech processor to produce substantial average improvements in SRT of 7.1 dB. The monaural, adaptive beamformer provided an averaged SRT improvement of 5.3 dB. Public Library of Science 2014-04-22 /pmc/articles/PMC3995709/ /pubmed/24755864 http://dx.doi.org/10.1371/journal.pone.0095542 Text en © 2014 Buechner et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Buechner, Andreas Dyballa, Karl-Heinz Hehrmann, Phillipp Fredelake, Stefan Lenarz, Thomas Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions |
title | Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions |
title_full | Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions |
title_fullStr | Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions |
title_full_unstemmed | Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions |
title_short | Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions |
title_sort | advanced beamformers for cochlear implant users: acute measurement of speech perception in challenging listening conditions |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3995709/ https://www.ncbi.nlm.nih.gov/pubmed/24755864 http://dx.doi.org/10.1371/journal.pone.0095542 |
work_keys_str_mv | AT buechnerandreas advancedbeamformersforcochlearimplantusersacutemeasurementofspeechperceptioninchallenginglisteningconditions AT dyballakarlheinz advancedbeamformersforcochlearimplantusersacutemeasurementofspeechperceptioninchallenginglisteningconditions AT hehrmannphillipp advancedbeamformersforcochlearimplantusersacutemeasurementofspeechperceptioninchallenginglisteningconditions AT fredelakestefan advancedbeamformersforcochlearimplantusersacutemeasurementofspeechperceptioninchallenginglisteningconditions AT lenarzthomas advancedbeamformersforcochlearimplantusersacutemeasurementofspeechperceptioninchallenginglisteningconditions |