Cargando…

Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia

BACKGROUND: Massive implementation of malaria diagnostics in low-resource countries is regarded as a pivotal strategy in control and elimination efforts. Although malaria rapid diagnostic tests (RDTs) are considered a viable alternative, there are still obstacles to the widespread implementation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Herrera, Sócrates, Vallejo, Andrés F, Quintero, Juan P, Arévalo-Herrera, Myriam, Cancino, Marcela, Ferro, Santiago
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3995821/
https://www.ncbi.nlm.nih.gov/pubmed/24612585
http://dx.doi.org/10.1186/1475-2875-13-87
_version_ 1782312943118974976
author Herrera, Sócrates
Vallejo, Andrés F
Quintero, Juan P
Arévalo-Herrera, Myriam
Cancino, Marcela
Ferro, Santiago
author_facet Herrera, Sócrates
Vallejo, Andrés F
Quintero, Juan P
Arévalo-Herrera, Myriam
Cancino, Marcela
Ferro, Santiago
author_sort Herrera, Sócrates
collection PubMed
description BACKGROUND: Massive implementation of malaria diagnostics in low-resource countries is regarded as a pivotal strategy in control and elimination efforts. Although malaria rapid diagnostic tests (RDTs) are considered a viable alternative, there are still obstacles to the widespread implementation of this strategy, such as reporting constraints and lack of proper quality assurance of RDT-based programmes at point-of-care (POC). METHODS: A prospective cohort of patients, seeking routine care for febrile episodes at health centres in malaria-endemic areas of Colombia, was used to assess the diagnostic performance of a device based on smartphone technology (Deki Reader(TM), former codename “GenZero”), that assists users at POC to process RDTs. After informed consent, patients were enrolled into the study and blood samples were collected for thick blood smear (TBS) and RDT. The RDT results were interpreted by both visual inspection and Deki Reader device and concordance between visual and device interpretation was measured. Microscopy corrected by real-time polymerase chain reaction (PCR) and microscopy were “gold standard” tests to assess the diagnostic performance. RESULTS: In total, 1,807 patients were enrolled at seven health centres in malaria-endemic areas of Colombia. Thirty-three Plasmodium falciparum and 100 Plasmodium vivax cases were positive by corrected microscopy. Both sensitivity and specificity were 93.9% (95% CI 69.7-95.2) and 98.7% (95% CI 98.5-99.4) for P. falciparum, and 98.0% (95% CI 90.3-98.9) and 97.9% (95% CI 97.1-98.5) for P. vivax. Percentage concordance between visual and device interpretation of RDT was 98.5% and 99.0% for P. vivax and P. falciparum, respectively.The RDT, when compared to TBS, showed high sensitivity and specificity for P. falciparum in both visual and device interpretation, and good overall diagnostic performance for P. vivax. Comparison between PCR as gold standard and visual and device interpretation showed acceptable overall performance for both species. CONCLUSIONS: The diagnostic performance of the Deki Reader was comparable to visual interpretation of RDTs (without significant differences) for both malaria species. Providing standardized automated interpretation of RDTs at POC in remote areas, in addition to almost real-time reporting of cases and enabling quality control would greatly benefit large-scale implementation of RDT-based malaria diagnostic programmes.
format Online
Article
Text
id pubmed-3995821
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39958212014-04-23 Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia Herrera, Sócrates Vallejo, Andrés F Quintero, Juan P Arévalo-Herrera, Myriam Cancino, Marcela Ferro, Santiago Malar J Research BACKGROUND: Massive implementation of malaria diagnostics in low-resource countries is regarded as a pivotal strategy in control and elimination efforts. Although malaria rapid diagnostic tests (RDTs) are considered a viable alternative, there are still obstacles to the widespread implementation of this strategy, such as reporting constraints and lack of proper quality assurance of RDT-based programmes at point-of-care (POC). METHODS: A prospective cohort of patients, seeking routine care for febrile episodes at health centres in malaria-endemic areas of Colombia, was used to assess the diagnostic performance of a device based on smartphone technology (Deki Reader(TM), former codename “GenZero”), that assists users at POC to process RDTs. After informed consent, patients were enrolled into the study and blood samples were collected for thick blood smear (TBS) and RDT. The RDT results were interpreted by both visual inspection and Deki Reader device and concordance between visual and device interpretation was measured. Microscopy corrected by real-time polymerase chain reaction (PCR) and microscopy were “gold standard” tests to assess the diagnostic performance. RESULTS: In total, 1,807 patients were enrolled at seven health centres in malaria-endemic areas of Colombia. Thirty-three Plasmodium falciparum and 100 Plasmodium vivax cases were positive by corrected microscopy. Both sensitivity and specificity were 93.9% (95% CI 69.7-95.2) and 98.7% (95% CI 98.5-99.4) for P. falciparum, and 98.0% (95% CI 90.3-98.9) and 97.9% (95% CI 97.1-98.5) for P. vivax. Percentage concordance between visual and device interpretation of RDT was 98.5% and 99.0% for P. vivax and P. falciparum, respectively.The RDT, when compared to TBS, showed high sensitivity and specificity for P. falciparum in both visual and device interpretation, and good overall diagnostic performance for P. vivax. Comparison between PCR as gold standard and visual and device interpretation showed acceptable overall performance for both species. CONCLUSIONS: The diagnostic performance of the Deki Reader was comparable to visual interpretation of RDTs (without significant differences) for both malaria species. Providing standardized automated interpretation of RDTs at POC in remote areas, in addition to almost real-time reporting of cases and enabling quality control would greatly benefit large-scale implementation of RDT-based malaria diagnostic programmes. BioMed Central 2014-03-10 /pmc/articles/PMC3995821/ /pubmed/24612585 http://dx.doi.org/10.1186/1475-2875-13-87 Text en Copyright © 2014 Herrera et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Herrera, Sócrates
Vallejo, Andrés F
Quintero, Juan P
Arévalo-Herrera, Myriam
Cancino, Marcela
Ferro, Santiago
Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia
title Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia
title_full Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia
title_fullStr Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia
title_full_unstemmed Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia
title_short Field evaluation of an automated RDT reader and data management device for Plasmodium falciparum/Plasmodium vivax malaria in endemic areas of Colombia
title_sort field evaluation of an automated rdt reader and data management device for plasmodium falciparum/plasmodium vivax malaria in endemic areas of colombia
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3995821/
https://www.ncbi.nlm.nih.gov/pubmed/24612585
http://dx.doi.org/10.1186/1475-2875-13-87
work_keys_str_mv AT herrerasocrates fieldevaluationofanautomatedrdtreaderanddatamanagementdeviceforplasmodiumfalciparumplasmodiumvivaxmalariainendemicareasofcolombia
AT vallejoandresf fieldevaluationofanautomatedrdtreaderanddatamanagementdeviceforplasmodiumfalciparumplasmodiumvivaxmalariainendemicareasofcolombia
AT quinterojuanp fieldevaluationofanautomatedrdtreaderanddatamanagementdeviceforplasmodiumfalciparumplasmodiumvivaxmalariainendemicareasofcolombia
AT arevaloherreramyriam fieldevaluationofanautomatedrdtreaderanddatamanagementdeviceforplasmodiumfalciparumplasmodiumvivaxmalariainendemicareasofcolombia
AT cancinomarcela fieldevaluationofanautomatedrdtreaderanddatamanagementdeviceforplasmodiumfalciparumplasmodiumvivaxmalariainendemicareasofcolombia
AT ferrosantiago fieldevaluationofanautomatedrdtreaderanddatamanagementdeviceforplasmodiumfalciparumplasmodiumvivaxmalariainendemicareasofcolombia