Cargando…
A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures
BACKGROUND: Failures to follow recommendations for reprocessing of surgical instruments may place patients at risk for exposure to pathogenic microorganisms. When such failures occur, medical facilities often face considerable uncertainty and challenges in assessing the actual risks of disease trans...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3996191/ https://www.ncbi.nlm.nih.gov/pubmed/24447336 http://dx.doi.org/10.1186/2047-2994-3-4 |
_version_ | 1782313008177872896 |
---|---|
author | Donskey, Curtis J Yowler, Marian Falck-Ytter, Yngve Kundrapu, Sirisha Salata, Robert A Rutala, William A |
author_facet | Donskey, Curtis J Yowler, Marian Falck-Ytter, Yngve Kundrapu, Sirisha Salata, Robert A Rutala, William A |
author_sort | Donskey, Curtis J |
collection | PubMed |
description | BACKGROUND: Failures to follow recommendations for reprocessing of surgical instruments may place patients at risk for exposure to pathogenic microorganisms. When such failures occur, medical facilities often face considerable uncertainty and challenges in assessing the actual risks of disease transmission. METHODS: In 2011, staff at an Ohio hospital determined that surgical instruments inside a Steriset Container had inadvertently been autoclaved on a gravity cycle rather than on the recommended pre-vacuum cycle, potentially exposing 72 patients who underwent surgery with the instruments to risk of infection. To provide an assessment of the level of risk, we tested the effectiveness of the machine washer/disinfector step and of the sterilization process inside the Steriset Container on the gravity cycle for killing of Geobacillus stearothermophilus spores, Clostridium difficile spores, and methicillin-resistant Staphylococcus aureus (MRSA). Based on the test results, the risk of transmission of MRSA by the instruments was calculated and the risk of transmission of hepatitis B virus was estimated. RESULTS: The machine washer/disinfector consistently reduced MRSA recovery by a factor of 1:100,000. The sterilization process inside the Steriset Container consistently reduced MRSA concentrations by a factor of >1:10,000,000 and killed 10(5)C. difficile spores and 10(5)G. stearothermophilus spores. The risk of MRSA transmission due to the incident was calculated to be 1 in 100 trillion. CONCLUSIONS: The risk for transmission of infection due to the failure to follow recommended sterilization processes was negligible based upon complete killing of G. stearothermophilus biological indicator spores, C. difficile spores, and MRSA under conditions that replicated the incident where proper procedures were not followed. Such real-time assessments of the risks associated with specific incidents may provide evidence-based information that can be used to inform decisions regarding disclosure of the incident to patients. |
format | Online Article Text |
id | pubmed-3996191 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-39961912014-04-24 A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures Donskey, Curtis J Yowler, Marian Falck-Ytter, Yngve Kundrapu, Sirisha Salata, Robert A Rutala, William A Antimicrob Resist Infect Control Research BACKGROUND: Failures to follow recommendations for reprocessing of surgical instruments may place patients at risk for exposure to pathogenic microorganisms. When such failures occur, medical facilities often face considerable uncertainty and challenges in assessing the actual risks of disease transmission. METHODS: In 2011, staff at an Ohio hospital determined that surgical instruments inside a Steriset Container had inadvertently been autoclaved on a gravity cycle rather than on the recommended pre-vacuum cycle, potentially exposing 72 patients who underwent surgery with the instruments to risk of infection. To provide an assessment of the level of risk, we tested the effectiveness of the machine washer/disinfector step and of the sterilization process inside the Steriset Container on the gravity cycle for killing of Geobacillus stearothermophilus spores, Clostridium difficile spores, and methicillin-resistant Staphylococcus aureus (MRSA). Based on the test results, the risk of transmission of MRSA by the instruments was calculated and the risk of transmission of hepatitis B virus was estimated. RESULTS: The machine washer/disinfector consistently reduced MRSA recovery by a factor of 1:100,000. The sterilization process inside the Steriset Container consistently reduced MRSA concentrations by a factor of >1:10,000,000 and killed 10(5)C. difficile spores and 10(5)G. stearothermophilus spores. The risk of MRSA transmission due to the incident was calculated to be 1 in 100 trillion. CONCLUSIONS: The risk for transmission of infection due to the failure to follow recommended sterilization processes was negligible based upon complete killing of G. stearothermophilus biological indicator spores, C. difficile spores, and MRSA under conditions that replicated the incident where proper procedures were not followed. Such real-time assessments of the risks associated with specific incidents may provide evidence-based information that can be used to inform decisions regarding disclosure of the incident to patients. BioMed Central 2014-01-21 /pmc/articles/PMC3996191/ /pubmed/24447336 http://dx.doi.org/10.1186/2047-2994-3-4 Text en Copyright © 2014 Donskey et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Research Donskey, Curtis J Yowler, Marian Falck-Ytter, Yngve Kundrapu, Sirisha Salata, Robert A Rutala, William A A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
title | A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
title_full | A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
title_fullStr | A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
title_full_unstemmed | A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
title_short | A case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
title_sort | case study of a real-time evaluation of the risk of disease transmission associated with a failure to follow recommended sterilization procedures |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3996191/ https://www.ncbi.nlm.nih.gov/pubmed/24447336 http://dx.doi.org/10.1186/2047-2994-3-4 |
work_keys_str_mv | AT donskeycurtisj acasestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT yowlermarian acasestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT falckytteryngve acasestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT kundrapusirisha acasestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT salataroberta acasestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT rutalawilliama acasestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT donskeycurtisj casestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT yowlermarian casestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT falckytteryngve casestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT kundrapusirisha casestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT salataroberta casestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures AT rutalawilliama casestudyofarealtimeevaluationoftheriskofdiseasetransmissionassociatedwithafailuretofollowrecommendedsterilizationprocedures |